Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z
Product |
Article Number (Market Facing Number) |
7MC7511-0NA06-0BA2-Z E00+T10+Y01 |
Product Description |
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text |
Product family |
Type 2, without process connection |
Product Lifecycle (PLM) |
PM300:Active Product |
Notes |
Please enter text for every Y option (using the Configurator). |
Price data |
Region Specific PriceGroup / Headquarter Price Group |
8T3 / 8T3 |
List Price |
Show prices |
Customer Price |
Show prices |
Surcharge for Raw Materials |
None |
Metal Factor |
None |
Delivery information |
Export Control Regulations |
ECCN : EAR99I / AL : N |
Standard lead time ex-works |
10 Day/Days |
Net Weight (kg) |
1,675 Kg |
Package size unit of measure |
Not available |
Quantity Unit |
1 Piece |
Packaging Quantity |
1 |
Additional Product Information |
EAN |
Not available |
UPC |
Not available |
Commodity Code |
90251900 |
LKZ_FDB/ CatalogID |
FI01-3 |
Product Group |
4785 |
Group Code |
R3P0 |
Country of origin |
France |
Compliance with the substance restrictions according to RoHS directive |
Since: 19.06.2015 |
Product class |
C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
WEEE (2012/19/EU) Take-Back Obligation |
Yes |
REACH Art. 33 Duty to inform according to the current list of candidates |
|
Classifications |
|
|
Version |
Classification |
eClass |
12 |
27-20-02-08 |
eClass |
6 |
27-20-02-08 |
eClass |
7.1 |
27-20-02-08 |
eClass |
8 |
27-20-02-08 |
eClass |
9 |
27-20-02-08 |
eClass |
9.1 |
27-20-02-08 |
UNSPSC |
15 |
32-15-17-03 |
|
Tham khảo thêm các model khác cùng loại:
7MC7511-.....-....
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571
7MC7512-.....-....
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435
7MC7511-1CA01-0AA1-Z E00+T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-0BA1-Z E00+T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-0BB1-Z E01+T21+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-0BB1-Z T20+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-9BA1-Z C11+E00+N1D+T10+Y01+Y15+Y33+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7511-1CA01-9BK6-Z E01+N3D+T41+Y01+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X=301 ... 450 mm Initial: 450 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 2xTC K, Cl.1 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
7MC7511-1CA03-9BA1-Z E00+N1D+T10+Y01+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7511-1CA04-0BA1-Z E00+T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA20-0CA1-Z E00+T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA20-0CA1-Z E01+T11+Y01+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
7MC7511-1CA22-1HA1-Z C12+C20+E00+T20+Y01+Y15+Y33+Y33
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Certificates: Functional safety: SIL2 conf. for transmitter TH200/300; SIL2/3+EN 50156-2 certificate for transmitter TH320/420 Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
7MC7511-1CB01-1BB2-Z E00+T40+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7511-1CB01-1CA1-Z C11+E01+T31+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CB01-9BB1-Z E00+N1D+T20+Y01+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7511-1CB02-9BB1-Z E00+N1D+T20+Y01+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7511-1CB06-1BB2-Z E00+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steels
7MC7511-1CK03-9BB5-Z E00+N1D+T10+Y01+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)
7MC7511-1CK04-1BB2-Z E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1CK12-1BB2-Z E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1EA88-9BA2-Z E01+N2D+T11+Y01+Y15+Y44+Y99
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
7MC7511-1JA10-0CA1-Z C11+E01+G20+T21+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1JA10-1CA1-Z C11+E23+G20+T33+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
7MC7511-2EA22-9GA2-Z E01+N2D+T11+Y01+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
7MC7511-2FA02-1AB1-Z C11+E01+T31+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7511-2FA04-1CA1-Z C11+E23+G20+T23+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
7MC7512-1CA01-0CA1-Z E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7512-1CA01-0MA1-Z E00+T20+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BM0; Plastic; Screw cover; IP54 (new from June 2016) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
7MC7512-1CA04-0CA1-Z T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7512-1CA14-0CA1-Z T10+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7512-1CA22-1BJ2-Z T40+Y01+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.1 -40 ... 750Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
7MC7512-1EA01-1CA2-Z C11+T10+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7512-1EA03-1MA2-Z C11+E00+T10+Y01+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BM0; Plastic; Screw cover; IP54 (new from June 2016) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
7MC7512-1EA25-1CA1-Z E01+T11+Y01+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
7MC7512-1JA41-9GK1-Z E03+N5D+T20+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 851 ... 900mm Initial: 900 Extension length EU type: X=601 ... 750 mm Initial: 750 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
7MC7512-2AA11-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 225 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
7MC7512-2AA12-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
7MC7512-2AB31-9BB2-Z E01+N1D+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7512-2AK27-1BB1-Z E00+T40+Y01+Y23
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point description (max. 16 characters) plain texts
7MC7512-9XA14-1BA2-Z C12+E00+H1Y+T10+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7511-0NA01-0BA3-Z A31+T10+Y01+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA01-0AA1-Z E01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA01-1AB1-Z E01+T11+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-1BB2-Z E00+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Length options: Specify special inst. length (in spec. area)s
7MC7511-0NA06-0AA3-Z A31+E01+T21+Y01+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA01-0BB1-Z E00+T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-0CA1-Z T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-1BA2-Z E01+T11+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA06-0AA1-Z E00+T20+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1CA10-0GA1-Z C11+E04+T21+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CA14-0AA1-Z T10+Y01+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA17-0BA2-Z E00+T30+Y01+Y17+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 345 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point number (TAG) (max. 8 characters) plain text Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA31-0CA1-Z E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1CB01-1BB1-Z E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-1BB1-Z E01+T21+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CA01-9BA1-Z E00+N1D+T10+Y01+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7511-1CA04-0BA1-Z T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA04-0BB1-Z T20+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text
7MC7511-1CA04-0CA1-Z C11+E04+T21+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CA04-9BA1-Z E00+N1D+T10+Y01+Y44+Y45
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
7MC7511-1CA10-0CA1-Z C11+E04+T21+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
7MC7511-1CA10-0GB1-Z C11+E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1CA20-0CB1-Z E00
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australias
7MC7511-1CA25-0AA1-Z E01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
7MC7511-1CA27-0CA3-Z T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1CA88-9BA1-Z E00+N1D+T10+Y01+Y44+Y45+Y99
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area) Processing number Special design: Specify in plain texts
7MC7511-1CK03-1BB3-Z C11+E00+T40+Y01+Y33
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
7MC7511-1CK04-1BB2-Z E00+T10+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
7MC7511-1JA01-0CA2-Z C11+E00+T40+Y01
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
7MC7511-1JA01-0GA2-Z E00+T10+Y01+Y15+Y44
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify s