Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z

Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z

1,160
Nhà sản xuất:

Siemens

;   

Xuất xứ: Germany

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z

 
Product
Article Number (Market Facing Number) 7MC7511-0NA06-0BA2-Z E00+T10+Y01
Product Description SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text
Product family Type 2, without process connection
Product Lifecycle (PLM) PM300:Active Product
Notes Please enter text for every Y option (using the Configurator).
Price data
Region Specific PriceGroup / Headquarter Price Group 8T3 / 8T3
List Price Show prices
Customer Price Show prices
Surcharge for Raw Materials None
Metal Factor None
Delivery information
Export Control Regulations ECCN : EAR99I / AL : N
Standard lead time ex-works 10 Day/Days
Net Weight (kg) 1,675 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN Not available
UPC Not available
Commodity Code 90251900
LKZ_FDB/ CatalogID FI01-3
Product Group 4785
Group Code R3P0
Country of origin France
Compliance with the substance restrictions according to RoHS directive Since: 19.06.2015
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
Reach Information
Classifications
 
  Version Classification
eClass 12 27-20-02-08
eClass 6 27-20-02-08
eClass 7.1 27-20-02-08
eClass 8 27-20-02-08
eClass 9 27-20-02-08
eClass 9.1 27-20-02-08
UNSPSC 15 32-15-17-03


Tham khảo thêm các model khác cùng loại:

7MC7511-.....-....

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571
 

7MC7512-.....-....

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435
 

7MC7511-1CA01-0AA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0BA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0BB1-Z E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0BB1-Z T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-9BA1-Z C11+E00+N1D+T10+Y01+Y15+Y33+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA01-9BK6-Z E01+N3D+T41+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X=301 ... 450 mm Initial: 450 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 2xTC K, Cl.1 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA03-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA04-0BA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA20-0CA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA20-0CA1-Z E01+T11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA22-1HA1-Z C12+C20+E00+T20+Y01+Y15+Y33+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Certificates: Functional safety: SIL2 conf. for transmitter TH200/300; SIL2/3+EN 50156-2 certificate for transmitter TH320/420 Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CB01-1BB2-Z E00+T40+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CB01-1CA1-Z C11+E01+T31+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB01-9BB1-Z E00+N1D+T20+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CB02-9BB1-Z E00+N1D+T20+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s


7MC7511-1CB06-1BB2-Z E00+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steels
 

7MC7511-1CK03-9BB5-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)
 

7MC7511-1CK04-1BB2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK12-1BB2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1EA88-9BA2-Z E01+N2D+T11+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-1JA10-0CA1-Z C11+E01+G20+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA10-1CA1-Z C11+E23+G20+T33+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7511-2EA22-9GA2-Z E01+N2D+T11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-2FA02-1AB1-Z C11+E01+T31+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-2FA04-1CA1-Z C11+E23+G20+T23+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0CA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0MA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BM0; Plastic; Screw cover; IP54 (new from June 2016) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA04-0CA1-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA14-0CA1-Z T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA22-1BJ2-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.1 -40 ... 750Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1EA01-1CA2-Z C11+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EA03-1MA2-Z C11+E00+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BM0; Plastic; Screw cover; IP54 (new from June 2016) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EA25-1CA1-Z E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1JA41-9GK1-Z E03+N5D+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 851 ... 900mm Initial: 900 Extension length EU type: X=601 ... 750 mm Initial: 750 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-2AA11-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 225 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA12-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AB31-9BB2-Z E01+N1D+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-2AK27-1BB1-Z E00+T40+Y01+Y23

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point description (max. 16 characters) plain texts
 

7MC7512-9XA14-1BA2-Z C12+E00+H1Y+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-0NA01-0BA3-Z A31+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0AA1-Z E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-1AB1-Z E01+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BB2-Z E00+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Length options: Specify special inst. length (in spec. area)s
 

7MC7511-0NA06-0AA3-Z A31+E01+T21+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0BB1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0CA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BA2-Z E01+T11+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA06-0AA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA10-0GA1-Z C11+E04+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA14-0AA1-Z T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA17-0BA2-Z E00+T30+Y01+Y17+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 345 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point number (TAG) (max. 8 characters) plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA31-0CA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB01-1BB1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BB1-Z E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA04-0BA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-0BB1-Z T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text
 

7MC7511-1CA04-0CA1-Z C11+E04+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA10-0CA1-Z C11+E04+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA10-0GB1-Z C11+E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA20-0CB1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australias
 

7MC7511-1CA25-0AA1-Z E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA27-0CA3-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA88-9BA1-Z E00+N1D+T10+Y01+Y44+Y45+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-1CK03-1BB3-Z C11+E00+T40+Y01+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CK04-1BB2-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA01-0CA2-Z C11+E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA01-0GA2-Z E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify s
Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Gọi điện thoại