Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z

Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z

694
Nhà sản xuất: Siemens;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Cảm biến nhiệt độ Siemens 7MC7511-0NA06-0BA2-Z

 
Product
Article Number (Market Facing Number) 7MC7511-0NA06-0BA2-Z E00+T10+Y01
Product Description SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text
Product family Type 2, without process connection
Product Lifecycle (PLM) PM300:Active Product
Notes Please enter text for every Y option (using the Configurator).
Price data
Region Specific PriceGroup / Headquarter Price Group 8T3 / 8T3
List Price Show prices
Customer Price Show prices
Surcharge for Raw Materials None
Metal Factor None
Delivery information
Export Control Regulations ECCN : EAR99I / AL : N
Standard lead time ex-works 10 Day/Days
Net Weight (kg) 1,675 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN Not available
UPC Not available
Commodity Code 90251900
LKZ_FDB/ CatalogID FI01-3
Product Group 4785
Group Code R3P0
Country of origin France
Compliance with the substance restrictions according to RoHS directive Since: 19.06.2015
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates
Reach Information
Classifications
 
  Version Classification
eClass 12 27-20-02-08
eClass 6 27-20-02-08
eClass 7.1 27-20-02-08
eClass 8 27-20-02-08
eClass 9 27-20-02-08
eClass 9.1 27-20-02-08
UNSPSC 15 32-15-17-03


Tham khảo thêm các model khác cùng loại:

7MC7511-.....-....

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571
 

7MC7512-.....-....

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435
 

7MC7511-1CA01-0AA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0BA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0BB1-Z E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0BB1-Z T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-9BA1-Z C11+E00+N1D+T10+Y01+Y15+Y33+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA01-9BK6-Z E01+N3D+T41+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X=301 ... 450 mm Initial: 450 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 2xTC K, Cl.1 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA03-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA04-0BA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA20-0CA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA20-0CA1-Z E01+T11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA22-1HA1-Z C12+C20+E00+T20+Y01+Y15+Y33+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Certificates: Functional safety: SIL2 conf. for transmitter TH200/300; SIL2/3+EN 50156-2 certificate for transmitter TH320/420 Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CB01-1BB2-Z E00+T40+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CB01-1CA1-Z C11+E01+T31+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB01-9BB1-Z E00+N1D+T20+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CB02-9BB1-Z E00+N1D+T20+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s


7MC7511-1CB06-1BB2-Z E00+Y15
SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steels
 

7MC7511-1CK03-9BB5-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)
 

7MC7511-1CK04-1BB2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK12-1BB2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1EA88-9BA2-Z E01+N2D+T11+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-1JA10-0CA1-Z C11+E01+G20+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA10-1CA1-Z C11+E23+G20+T33+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7511-2EA22-9GA2-Z E01+N2D+T11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-2FA02-1AB1-Z C11+E01+T31+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-2FA04-1CA1-Z C11+E23+G20+T23+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0CA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0MA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BM0; Plastic; Screw cover; IP54 (new from June 2016) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA04-0CA1-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA14-0CA1-Z T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA22-1BJ2-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.1 -40 ... 750Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1EA01-1CA2-Z C11+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EA03-1MA2-Z C11+E00+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BM0; Plastic; Screw cover; IP54 (new from June 2016) Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EA25-1CA1-Z E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1JA41-9GK1-Z E03+N5D+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 851 ... 900mm Initial: 900 Extension length EU type: X=601 ... 750 mm Initial: 750 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-2AA11-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 225 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA12-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AB31-9BB2-Z E01+N1D+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-2AK27-1BB1-Z E00+T40+Y01+Y23

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point description (max. 16 characters) plain texts
 

7MC7512-9XA14-1BA2-Z C12+E00+H1Y+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-0NA01-0BA3-Z A31+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0AA1-Z E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-1AB1-Z E01+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BB2-Z E00+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Length options: Specify special inst. length (in spec. area)s
 

7MC7511-0NA06-0AA3-Z A31+E01+T21+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0BB1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0CA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BA2-Z E01+T11+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA06-0AA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA10-0GA1-Z C11+E04+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA14-0AA1-Z T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA17-0BA2-Z E00+T30+Y01+Y17+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 345 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point number (TAG) (max. 8 characters) plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA31-0CA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB01-1BB1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BB1-Z E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA04-0BA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-0BB1-Z T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text
 

7MC7511-1CA04-0CA1-Z C11+E04+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA10-0CA1-Z C11+E04+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA10-0GB1-Z C11+E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA20-0CB1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australias
 

7MC7511-1CA25-0AA1-Z E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA27-0CA3-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA88-9BA1-Z E00+N1D+T10+Y01+Y44+Y45+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-1CK03-1BB3-Z C11+E00+T40+Y01+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CK04-1BB2-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA01-0CA2-Z C11+E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA01-0GA2-Z E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1JA01-1BA5-Z C12+E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australias
 

7MC7511-1JA03-1GK1-Z E00+G20+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Requirements non-Ex IECEx) For EU / Australia Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1JA10-0CA1-Z C11+E23+G20+T23+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JK06-1BB2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA51-1BA2-Z E00+T10+Y01+Y17

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point number (TAG) (max. 8 characters) plain texts
 

7MC7511-2AK03-1BB2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0MA3

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435s
 

7MC7512-1CA01-1CA2-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text
 

7MC7512-1CA12-0CA2-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA12-1CA2-Z C11+E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA27-0CA1-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CK03-1CA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CK15-1CB3-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 301 ... 320mm Initial: 315 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1JB01-1CA3-Z T10+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-2AA05-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 161...180 Initial: 180 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA13-1CA2-Z C11+C12+E00+T40+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 261 ... 280mm Initial: 280 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA51-1GA1-Z E03+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-2AB31-9BB2-Z E01+N4D+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 501 ... 550mm Initial: 510 Extension length EU type: X=451 ... 600 mm Initial: 600 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-2CA11-1CA1-Z A03+E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 225 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Accessories: With inner grounding screw Requirements non-Ex IECEx) For EU / Australias
 

7MC7512-4CA02-1CA1-Z C12+E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XA14-1CA2-Z C11+C12+E01+H1Y+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XB17-1BC1-Z C11+E00+H1Y+T20+Y01+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 341 ... 360mm Initial: 345 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Processing number Special design: Specify in plain texts
 

7MC7511-1CB02-1BB1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK04-1CB2-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK14-1CB1-Z E00+T20+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CK15-9BB1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 301 ... 320mm Initial: 315 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1EK04-1AA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA03-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)
 

7MC7511-1JA10-0CA1-Z C11+E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA02-1CB7-Z T45+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Transmitter: SITRANS TH400, FOUNDATION Fieldbus, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA11-1CA1-Z C11+E04+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 225 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-2EA04-1CA1-Z C11+E23+G20+T23+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0AA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0BA3

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435s
 

7MC7512-1CA01-1CA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-1CA2-Z C11+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA01-1CB1-Z E00+T20+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA04-0CA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA14-0CA1-Z T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CB01-1BA1-Z E00+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CK13-1CA2-Z E00+T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 261 ... 280mm Initial: 280 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1EA12-1CA2-Z C11+E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA88-1CA1-Z C12+E01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-4CA01-1CA5-Z C12+E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-4CA06-1CA5-Z C12+E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-4CA32-1CA2-Z C11+E00+G12+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Head cable inlet M12 connector Maximum IP 65/67 Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-0NA12-0AA3-Z A31+E01+T21+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0AA1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 401 ... 420mm Initial: 420 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Transmitter options: Measuring point number (TAG) (max. 8 characters) plain texts
 

7MC7512-9XA27-1CA2-Z C11+H1Y+T10+Y01+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Processing number Special design: Specify in plain texts
 

7MC7512-9XA32-1GA2-Z C11+E03+H1Y+T10+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-1CA01-0BB1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0CA1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australias
 

7MC7511-1CA01-0HB2-Z E01+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BA2-Z E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-9BA1-Z C11+E00+N1D+T10+Y01+Y15+Y33+Y33+Y33+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Carry out factory calibration at one point, specify desired temperature in plain text Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA01-9BA3-Z E01+N1D+T11+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CA03-0BA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-0AA3-Z C20+E01+T21+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Certificates: Functional safety: SIL2 conf. for transmitter TH200/300; SIL2/3+EN 50156-2 certificate for transmitter TH320/420 Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA06-0BB1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA15-1CA1-Z E01+T41+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 301 ... 320mm Initial: 315 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA43-0AA1-Z C11+E00+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 951 ... 1000mm Initial: 1000 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA51-0AA1-Z E00+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CB27-1AA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB36-1AK1-Z C20+E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 751 ... 800mm Initial: 800 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Certificates: Functional safety: SIL2 conf. for transmitter TH200/300; SIL2/3+EN 50156-2 certificate for transmitter TH320/420 Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB36-1AK1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 751 ... 800mm Initial: 800 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK04-1HB2-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK33-1BB2-Z E00+T10+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 601 ... 650mm Initial: 650 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel
 

7MC7511-1EA01-1BA2-Z E01+T11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1EA04-1CA1-Z E04+T41+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain texts
 

7MC7511-1EA24-1CA2-Z C11+E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 421 ... 440mm Initial: 440 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1EB01-1CA1-Z C11+E01+T31+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1EB04-9AA1-Z E00+N1D+Y15+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1JA03-1GK1-Z E01+G20+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1JA04-9BA1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-2AK37-1BB1-Z E01+T41+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 801 ... 850mm Initial: 850 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-2FA03-1AB1-Z C11+E01+T31+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 300 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA32-0BB2-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1JA01-0AB2-Z C34+C35+E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Visual, dimensional, and functional inspection Compliance declaration DIN EN 10204-2.1: Declaration of compliance with the order Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA06-1CA2-Z C11+C12+E00+T10+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA27-1GA1-Z E03+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-2AK36-1BK1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 751 ... 800mm Initial: 800 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Requirements non-Ex IECEx) For EU / Australias
 

7MC7512-2CB22-1BA1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australias
 

7MC7512-2EA02-1CA1-Z E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XA01-1CA2-Z C11+E00+H1Y+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0BA2-Z E01+T31+Y01+Y17+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point number (TAG) (max. 8 characters) plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-0HA1-Z E00+T30+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1CB1-Z E00+T40+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)
 

7MC7511-1CA04-0AA1-Z E00+T30+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA04-0BA1-Z E01+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-1BB1-Z E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA05-0HA1-Z T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 161...180 Initial: 180 Extension: Without Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA10-0CA3-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA44-0BA2-Z E01+T31+Y01+Y17+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 1001 ... 1100mm Initial: 1100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Transmitter options: Measuring point number (TAG) (max. 8 characters) plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CB01-1CA1-Z E01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dusts
 

7MC7511-1CK03-9BB1-Z E00+N1D+T10+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1EB01-1CA1-Z C11+E03+T31+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA04-0CA1-Z C11+E23+G20+T23+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA01-1BA3-Z E01+T11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-2AK51-1BB1-Z E01+T41+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-2EA02-1CA1-Z C11+E23+G20+T23+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH200, 4-20 mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7511-2EA10-1CA1-Z C11+E23+G20+T33+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0CA1-Z E01+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0CA1-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0CA3-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA03-0AA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA04-1CA2-Z C11+E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA12-0CA2-Z E00+T10

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100
 

7MC7512-1CA14-0CA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA32-1BJ1-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.2 -40 ... 750Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1CA32-1BJ2-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.1 -40 ... 750Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1EA03-1CA2-Z C11+E01+T11+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EA03-1CA2-Z C11+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2EK51-1AA2-Z E01+T31+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-4CA01-1CA1-Z C12+E01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XA14-1CA2-Z C11+C12+E00+H1Y+T10+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XA14-1CA2-Z C11+C12+E00+H1Y+T10+Y01+Y15+Y33+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-9XA27-1CA2-Z C11+H1Y+T10+Y01+Y15+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Processing number Special design: Specify in plain texts
 

7MC7512-9XA32-1GA2-Z C11+E03+H1Y+T10+Y01+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-0NA04-0BA2-Z A31+E00+T10+Y01+Y15+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Compression fitting G 1/2" (enclosed) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CA01-0AB1

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571s
 

7MC7511-1CA01-0BA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-1BA1-Z C35+E00+T24+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Compliance declaration DIN EN 10204-2.1: Declaration of compliance with the order Requirements non-Ex IECEx) For EU / Australia Transmitter: Sitrans TH320, Input: 1 x universal, Output: 4 ... 20 mA Current high delivery time! Shortening by selecting TH200 "E20" (N-Ex); "E23" ("i" FM) ; E21 ("i" EU/IECEx) Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA01-1BA2-Z E01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dusts
 

7MC7511-1CA04-0BA2-Z E00+T10

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100s
 

7MC7511-1CA04-0BA2-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-1CB1-Z E00+T40+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA06-0CA1-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel
 

7MC7511-1CA22-1CA1-Z E01+T41+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA25-0AA1-Z E00+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA44-0AA1-Z E00+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 1001 ... 1100mm Initial: 1100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CB03-1CB2-Z E00+T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1EA22-9CC1-Z C11+N1D+T40+Y01+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1JA10-0CA1-Z C11+E23+G20+T33+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: cFMus Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA04-1BA1-Z C11+E01+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA22-1CA1-Z C11+E04+T11+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-2EA01-9GA1-Z E01+N2D+T31+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1CA04-1UC1-Z T40+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AU0; Stainless steel; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA16-0CA3-Z C11+E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 321 ... 340mm Initial: 340 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA22-1CB2-Z C11+E01+T21+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA27-1CA2-Z C11+E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA88-1CB2-Z C11+E00+T20+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-1CB17-1BC1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 341 ... 360mm Initial: 345 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1DB02-9CA1-Z E00+N1D+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 3/4" (3/4"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7512-2AA14-1BA3-Z E01+T31+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AB06-9BB2-Z C11+E01+N1D+T31+Y01+Y33+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-9XA01-1CA2-Z C11+E00+H1Y+T10+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-9XA14-1CA2-Z C11+C12+E00+H1Y+T40+Y01+Y15+Y33+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain text
 

7MC7512-9XA14-1CA2-Z C11+C12+E01+H1Y+T41+Y01+Y15+Y33+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-9XA32-1GA2-Z C11+E03+H1Y+T10+Y01+Y15+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Processing number Special design: Specify in plain texts
 

7MC7512-9XA32-1GA2-Z C11+E03+H1Y+T10+Y01+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Processing number Special design: Specify in plain texts
 

7MC7511-0NA01-0AA3-Z A31+E01+T21+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Compression fitting G 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-0NA36-0CK5-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Without Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 751 ... 800mm Initial: 800 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 2xTC K, Cl.2 -40 ... 1000Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA01-0AA1-Z E00+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA04-0BA1-Z T30+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA04-0BA2-Z E00+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA04-0BA2-Z T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA04-0BB1-Z E01+T21+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA06-0CA1-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australias
 

7MC7511-1CA10-0GA1-Z C11+E03+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA10-0UA2-Z C11+T20+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AU0; Stainless steel; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA12-0BA1-Z T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 241 ... 260mm Initial: 250 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CB11-9BA1-Z E00+N1D+T10+Y01+Y15+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 221 ... 240mm Initial: 225 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CK03-1BA1-Z E00+T20+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK33-1BB2

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571s
 

7MC7511-1CK33-1BB2-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 601 ... 650mm Initial: 650 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CK43-1GB2-Z T30+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 951 ... 1000mm Initial: 1000 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1JA20-0GA2-Z E03+T10+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 341 ... 360mm Initial: 360 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel
 

7MC7511-2AB04-9CC1-Z C11+E04+N1D+T21+Y01+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special length ext. (in spec. area)s
 

7MC7512-0NK07-0BB2-Z A32+E01+T31+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Without Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 201...220 Initial: 220 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Compression fitting NPT 1/2" (enclosed) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA01-0BA1-Z E00+T30+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA05-9CB2-Z E00+N1D+T40+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 161...180 Initial: 180 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-1CA10-0BA3-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Requirements non-Ex IECEx) For EU / Australias
 

7MC7512-1CA22-1BJ1-Z T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.2 -40 ... 750Cel Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1CA22-1CB2-Z C11+E00+T20+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA88-1CB2-Z C11+E01+T21+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U= Special length-less than 80 mm or greather than 1500 mm (Y44, Y99 required in addition) Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-1CK03-1CB3-Z E00+T10+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EA01-1CA2-Z C11+E01+T11+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1EK27-1UA1-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1" (1"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AU0; Stainless steel; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1JA01-1CA2-Z E00+T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1JA01-9AB2-Z C34+C35+E01+N1D+T11+Y01+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Visual, dimensional, and functional inspection Compliance declaration DIN EN 10204-2.1: Declaration of compliance with the order Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-2AA05-1CA2-Z C11+C12+E00+T10+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 161...180 Initial: 180 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2AA14-1GA1-Z E03+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-2AB03-9BB2-Z C11+E01+N1D+T31+Y01+Y33+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-2AB36-9BB2-Z E01+N4D+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 751 ... 800mm Initial: 800 Extension length EU type: X=451 ... 600 mm Initial: 600 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-4CA32-1GA2-Z C11+E03+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-4DB14-9BB2-Z E01+N4D+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 80 PN10-16 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: X=451 ... 600 mm Initial: 600 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7512-9XA14-1CA2-Z C11+C12+E00+H1Y+T40+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)
 

7MC7512-9XA25-1CA2-Z C12+E01+H1Y+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 441 ... 460mm Initial: 460 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-1CA01-0AA1-Z E00+T30+Y01+Y15+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CA01-0BB1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-1CA01-0CA1-Z E81

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (GOST) For EAC Intrinsic safety ia,"ic" gas / dusts
 

7MC7511-1CA01-1AB1-Z E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA03-0BA1-Z E00+T40+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7511-1CA04-0GC1-Z E01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dusts
 

7MC7511-1CA04-0HA2-Z C11+C12+E00+T10+Y01+Y15+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension: Without Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CA10-0GA2-Z C11+T20+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA10-0GA3-Z C11+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 221 ... 240mm Initial: 230 Extension: Without Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.AA 0 ... 150Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CA22-1HA1-Z C12+E00+T30+Y01+Y15+Y33+Y33

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Carry out factory calibration at one point, specify desired temperature in plain texts
 

7MC7511-1CA47-0UA2-Z C11+T20+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 1301 ... 1400mm Initial: 1400 Extension: Without Connection head type: AU0; Stainless steel; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1CB01-9BA1-Z E00+N1D+T20+Y01+Y15+Y44+Y45

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area)s
 

7MC7511-1CB06-1CB2-Z E00+T40+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7511-1JA02-0CB7

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571s
 

7MC7511-1JA22-0HA1-Z E01+T31+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread NPT 1/2" Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension: Without Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH300, HART, 4-20mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain texts
 

7MC7511-2AA02-1CB7-Z T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.AA 0 ... 150Cel; Increased vibration resist. Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7511-2EA04-1CA1-Z E23+G20

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (CSA) For the USA and Canada Non-sparking n/ NI gas Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66s
 

7MC7511-9XA03-9HB1-Z C11+E00+H1Y+N1D+T10+Y01+Y15+Y44+Y45+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 121...140 Initial: 140 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7511-9XK51-9CC1-Z E04+H1Y+N1D+Y44+Y45+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -196 ... 600Cel; Extended measuring range Explosion protection (ATEX, IECEx) For EU / Australia Non-sparking ec gas Length options: Specify special inst. length (in spec. area) Length options: Specify special length ext. (in spec. area) Processing number Special design: Specify in plain text
 

7MC7512-1CA01-0AB2-Z C34+C35+E01+T11+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Visual, dimensional, and functional inspection Compliance declaration DIN EN 10204-2.1: Declaration of compliance with the order Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA01-1CA2-Z C11+E00+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA01-1CB2-Z C11+E00+T20+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA02-0BA2-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 101...120 Initial: 120 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA14-0CA1-Z T10+Y01+Y15

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steels
 

7MC7512-1CA27-0CA1-Z E00+T40+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH400, PROFIBUSPA, universal Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CA36-1CB1-Z E00+T20+Y01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 751 ... 800mm Initial: 800 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CA43-0CB2-Z C11+E00+T20+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 951 ... 1000mm Initial: 1000 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Increased vibration resist. Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CB04-1BA1-Z E00+T10+Y01

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 141...160 Initial: 160 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain texts
 

7MC7512-1CK22-1AB1-Z E00+G01+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 381 ... 400mm Initial: 400 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Increased vibration resist. Requirements non-Ex IECEx) For EU / Australia Special design: Connection form free wire ends (instead of clamping piece) Delivery without screws and springs Length options: Specify special inst. length (in spec. area)s
 

7MC7512-1CK51-1CK2-Z E00

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 3/3G/3F acc. to DIN 43772; D=12 D2= 9 (tapered) Insertion length (mm): U = 1401 ... 1500mm Initial: 1500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.1 -40 ... 1000Cel Requirements non-Ex IECEx) For EU / Australias
 

7MC7512-1DB02-9CA1-Z E00+N1D+T10+Y01+Y15+Y16

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 3/4" (3/4"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Additional information on TAG plate in plain texts
 

7MC7512-1DB02-9CA1-Z E00+N1D+T10+Y01+Y16

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Thread G 3/4" (3/4"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 101...120 Initial: 120 Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Additional information on TAG plate in plain texts
 

7MC7512-2AA06-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 25 PN10-40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 181...200 Initial: 200 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2CA14-1CA2-Z C11+C12+E01+T41+Y01+Y15+Y33+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange DN 50 PN40 According to DIN EN 1092-1 Sealing-face initial: B1 Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Inspection certificate DIN EN 10204-3.1: Material Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH400, PROFIBUSPA, universal Ex: ATEX/FM/CSA Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Carry out factory calibration at one point, specify desired temperature in plain text Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2EB01-1CA1-Z E00+T34+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange 1.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: Sitrans TH320, Input: 1 x universal, Output: 4 ... 20 mA; HART Current high delivery time! Shortening by selecting TH300 E30 (N-Ex); "E33" ("i" FM) ; E31 ("i" EU/IECEx) Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-2JB01-1CA1-Z E00+T34+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Process connection: Flange 2.0 inch, Class 150 According to ASME B16.5 Sealing-face initial: RF Thermowell form: 2/2G/2F acc. to DIN 43772; D=12 Insertion length " mm " : 80...100 Initial: 100 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex IECEx) For EU / Australia Transmitter: Sitrans TH320, Input: 1 x universal, Output: 4 ... 20 mA; HART Current high delivery time! Shortening by selecting TH300 E30 (N-Ex); "E33" ("i" FM) ; E31 ("i" EU/IECEx) Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XA14-1BA2-Z C12+E00+H1Y+T10+Y01+Y15+Y44+Y99

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 281 ... 300mm Initial: 285 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Material Requirements non-Ex IECEx) For EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area) Processing number Special design: Specify in plain texts
 

7MC7512-9XA27-1CA2-Z C11+H1Y+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 481 ... 500mm Initial: 500 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)s
 

7MC7512-9XA32-1GA2-Z C11+E03+H1Y+T10+Y01+Y15+Y44

SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316L/1.4404 or 1.4435 Additional options: P-conn Customer specific process connection (plain text descr.) Thread: type and size Flange: DN, PN, sealing and standard Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length (mm): U = 551 ... 600mm Initial: 600 Extension length EU type: Standard length of selected Thermowell form (DIN); Sensor spring at DIN measuring insert Connection head type: AG0; Aluminum; Screw cover; IP66/68 Ex d in combination with "E03" Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Explosion protection (ATEX, IECEx) For EU / Australia Pressure-resistant encapsulation d, "tb" gas / dust Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)
Sản phẩm cùng loại
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại