Pepperl Fuchs UB250-F77-E2-V31 là Cảm biến siêu âm phát hiện trực tiếp, 20-250mm IP67 20-30VDC Ripple 10%SS 1xSwitch PNP NO cULus Listed Class 2 Đầu nối M8x1 4-Pin Polycarbonate

 

Datasheet excerpt: Technical data of  UB250-F77-E2-V31

Product Description
Ultrasonic direct detection sensor
General specifications
Sensing range 20 ... 250 mm
Adjustment range 45 ... 250 mm
Dead band 0 ... 20 mm
Standard target plate 20 mm x 20 mm
Transducer frequency approx. 400 kHz
Response delay ≤ 50 ms
Limit data
Permissible cable length max. 300 m
Indicators/operating means
LED yellow switching state and flashing: Teach-In
Electrical specifications
Rated operating voltage 24 V DC
Operating voltage 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %
No-load supply current ≤ 20 mA
Time delay before availability ≤ 150 ms
Input
Input type 1 program input
Level low level : 0 ... 0.7 V (Teach-In active)
high level : UB or open input (Teach-In inactive)
Input impedance 16 kΩ
Pulse length ≥ 3 s
Output
Output type 1 switch output PNP, NO
Rated operating current 200 mA , short-circuit/overload protected
Voltage drop ≤ 2 V
Repeat accuracy ± 1 mm
Switching frequency   10 Hz
Range hysteresis typ. 2.5 mm
Off-state current ≤ 0.01 mA
Temperature influence 0.17 %/K
Compliance with standards and directives
Standard conformity  
  Standards EN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Approvals and certificates
EAC conformity TR CU 020/2011
TR CU 037/2016
UL approval cULus Listed, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Shock resistance 30 g , 11 ms period
Vibration resistance 10 ... 55 Hz , Amplitude ± 1 mm
Mechanical specifications
Connection type M8 x 1 connector , 4-pin
Degree of protection IP67
Material  
  Housing Polycarbonate
  Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Installation position any position
Mass 10 g
Tightening torque, fastening screws max. 0.2 Nm
Factory settings
Output Switching point: 250 mm

 

Classifications

System Classcode
ECLASS 11.0 27272803
ECLASS 10.0.1 27272803
ECLASS 9.0 27272803
ECLASS 8.0 27272803
ECLASS 5.1 27272803
ETIM 8.0 EC001849
ETIM 7.0 EC001849
ETIM 6.0 EC001849
ETIM 5.0 EC001849
UNSPSC 12.1 41111960


- Xem chi tiết Tài liệu kỹ thuật/ Datasheet Pepperl Fuchs UB250-F77-E2-V31 ở đây.


Tham khảo thêm các model khác cùng loại:

UB100-F77-E2-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output PNP, NO, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB250-F77-E2-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output PNP, NO, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB400-F77-E2-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output PNP, NO, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UC2000-L2-E6-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC250-F77-EP-IO-V31

Ultrasonic sensor
Single head system, IO-link interface for service and process data, Programmable via DTM with PACTWARE, Continuous distance value via IO-Link process data, Series: -F77, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC4000-L2-E6-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC800-F77S-EP-IO-V31

Ultrasonic sensor
Single head system, IO-link interface for service and process data, Programmable via DTM with PACTWARE, Continuous distance value via IO-Link process data, Series: -F77, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC4000-L2-U-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 12 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC4000-L2-I-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UB2000-F42-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 17 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB5000-F42-UK-V95

Ultrasonic sensor
Single head system, Relay output for high power, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 22 ... 253 V AC/DC, Output type: 1 relay output, Connection: 5-pin V95 connector (7/8"-16 UN 2A), Housing: PBT
 

UC2000-L2-I-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC400-F77-EP-IO-V31

Ultrasonic sensor
Single head system, IO-link interface for service and process data, Programmable via DTM with PACTWARE, Continuous distance value via IO-Link process data, Series: -F77, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UB2000-F42-E5-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F42-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F42S-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 17 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB4000-F42-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 17 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UC10000-F260-IE8R2

Ultrasonic sensor
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 current output 4 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose
 

UC10000-F260-IE9R2

Ultrasonic sensor
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NC, Output type: 1 current output 4 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose
 

UC2000-L2-E5-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC800-F77S-IU-IO-V31

Ultrasonic sensor
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M8 x 1 , 4-pin, Housing: Polycarbonate
 

UB100-F77-E0-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output E0, NPN, NO, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB100-F77-E1-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output E1, NPN, NC, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB100-F77-E3-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output PNP , NC contact, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB1500-F42-UK-V95

Ultrasonic sensor
Single head system, Relay output for high power, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 22 ... 253 V AC/DC, Output type: 1 relay output, Connection: 5-pin V95 connector (7/8"-16 UN 2A), Housing: PBT
 

UB1500-F42S-UK-V95

Ultrasonic sensor
Single head system, Relay output for high power, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 22 ... 253 V AC/DC, Output type: 1 relay output, Connection: 5-pin V95 connector (7/8"-16 UN 2A), Housing: PBT
 

UB2000-F42-E4-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F42-E6-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F42S-E5-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F42S-E6-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F42S-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F54-E5-V15

Ultrasonic sensor
Single head system, Switch output, 5 different output functions can be set, Program input, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switch output E5, PNP, NO/NC, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F54-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Measuring window adjustable, Program input, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB2000-F54-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Measuring window adjustable, Program input, Series: -F54, Operating voltage: 15 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB250-F77-E0-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output E0, NPN, NO, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB250-F77-E1-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output E1, NPN, NC, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB250-F77-E3-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output PNP , NC contact, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB250-F77-F-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Frequency output, Program input, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: Frequency output , PNP, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB3000-F42-UK-V95

Ultrasonic sensor
Single head system, Relay output for high power, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 22 ... 253 V AC/DC, Output type: 1 relay output, Connection: 5-pin V95 connector (7/8"-16 UN 2A), Housing: PBT
 

UB400-F42-UK-V95

Ultrasonic sensor
Single head system, Relay output for high power, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 22 ... 253 V AC/DC, Output type: 1 relay output, Connection: 5-pin V95 connector (7/8"-16 UN 2A), Housing: PBT
 

UB400-F42S-UK-V95

Ultrasonic sensor
Single head system, Relay output for high power, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 22 ... 253 V AC/DC, Output type: 1 relay output, Connection: 5-pin V95 connector (7/8"-16 UN 2A), Housing: PBT
 

UB400-F77-E0-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output E0, NPN, NO, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB400-F77-E1-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output E1, NPN, NC, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB400-F77-E3-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Program input, Degree of protection IP67, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: 1 switch output PNP , NC contact, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB400-F77-F-V31

Ultrasonic direct detection sensor
Ultrasonic direct detection sensor, Miniature design, Frequency output, Program input, Series: -F77, Rated operating voltage: 24 V DC, Operating voltage: 20 ... 30 V DC , ripple 10 %SS ; 12 ... 20 V DC sensitivity reduced to 90 %, Output type: Frequency output , PNP, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector , 4-pin, Housing: Polycarbonate
 

UB4000-F42-E5-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB4000-F42-E6-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB4000-F42-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 17 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-E4-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-E5-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-E6-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-E6-V15-Y70123089

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, Synchronization options, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NC, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42-E7-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, normally open/close selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42S-E4-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42S-E5-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42S-E6-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42S-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F42S-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 17 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F54-E5-V15

Ultrasonic sensor
Single head system, Switch output, 5 different output functions can be set, Program input, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switch output E5, PNP, NO/NC, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F54-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Measuring window adjustable, Program input, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB500-F54-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Measuring window adjustable, Program input, Series: -F54, Operating voltage: 15 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABS
 

UB6000-F42-E4-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB6000-F42-E5-V15

Ultrasonic sensor
Single head system, Switch output, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB6000-F42-E6-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB6000-F42-E7-V15

Ultrasonic sensor
Single head system, 2 independent switch outputs, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, normally open/close selectable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS

UB6000-F42-I-V1-Y220443
Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, Temperature compensation, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 4-pin, Connection: 4-pin, M12 x 1 connector
 

UB6000-F42-I-V15

Ultrasonic sensor
Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UB6000-F42-U-V15

Ultrasonic sensor
Single head system, Analog output 0 ... 10 V, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 17 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector M12 x 1 , 5-pin, Housing: ABS
 

UC10000-F260-IE8R2-Y250792

Ultrasonic sensor
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 current output 0 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose
 

UC10000-F260-IE9R2-Y250793

Ultrasonic sensor
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NC, Output type: 1 current output 0 ... 20 mA rising ramp  , UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose
 

UC10000-F260-UE8R2

Ultrasonic sensor
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, Output type: 1 voltage output: 0 ... 10 V rising ramp  , UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose
 

UC10000-F260-UE9R2

Ultrasonic sensor
Single head system, Large sensing range, Adjustable Bracket, Programmable by means of Interface (see accessories) and SONPROG, Series: F260, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NC, Output type: 1 voltage output: 0 ... 10 V rising ramp  , UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose
 

UC1500-F65-E8R2-V15

Ultrasonic sensor
Level indication , 2 switch outputs, Program input, Series: F65, Rated operating voltage: 24 V DC, Operating voltage: 12 ... 30 V (including ripple)
In supply voltage interval 12 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PBT
 

UC1500-F65-IE2R2-V15

Ultrasonic sensor
Level indication , 1 analog output, 4-20 mA current source, 1 switch output, Series: F65, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 1 switch output PNP, NO, Output type: 1 current output 4 ... 20 mA , rising ramp, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC1500-F65-UE2R2-V15

Ultrasonic sensor
Level indication , 1 analog output, 0-10 V voltage source, 1 switch output, Series: F65, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 1 switch output PNP, NO, Output type: 1 voltage output 0 ... 10 V , rising ramp, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC2000-L2-E4-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC2000-L2-E7-V15

Ultrasonic sensor
 Add to Watch List
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC2000-L2-U-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 12 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC2000-L2M-E5-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Selectable sound lobe width, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC2000-L2M-E6-T-2M

Ultrasonic sensor
Single head system, Extended temperature range, Cable connection, Rugged metal base, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable , 5-pin, Housing: PA-GF35
 

UC2000-L2M-E7-T-2M

Ultrasonic sensor
Single head system, Extended temperature range, Cable connection, Rugged metal base, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable , 5-pin, Housing: PA-GF35
 

UC2000-L2M-I-T-2M

Ultrasonic sensor
Single head system, Extended temperature range, Cable connection, Rugged metal base, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable , 5-pin, Housing: PA-GF35
 

UC2000-L2M-U-T-2M

Ultrasonic sensor
Single head system, Extended temperature range, Cable connection, Rugged metal base, Series: -L2, Operating voltage: 12 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 0 ... 10 V, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable , 5-pin, Housing: PA-GF35
 

UC250-F77-EP-IO-0,2M-V31

Ultrasonic sensor
Single head system, IO-link interface for service and process data, Programmable via DTM with PACTWARE, Continuous distance value via IO-Link process data, Series: -F77, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC250-F77-IU-IO-2M

Ultrasonic sensor
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable PUR , 2 m, Housing: Polycarbonate
 

UC250-F77-IU-IO-5M

Ultrasonic sensor
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: cable PUR , 5 m, Housing: Polycarbonate
 

UC250-F77-IU-IO-V31

Ultrasonic sensor
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M8 x 1 , 4-pin, Housing: Polycarbonate
 

UC2500-F65-E8R2-V15

Ultrasonic sensor
Level indication , 2 switch outputs, Program input, Series: F65, Rated operating voltage: 24 V DC, Operating voltage: 12 ... 30 V (including ripple)
In supply voltage interval 12 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 2 switch outputs PNP, NO, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PBT
 

UC2500-F65-IE2R2-V15

Ultrasonic sensor
Level indication , 1 analog output, 4-20 mA current source, 1 switch output, Series: F65, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 1 switch output PNP, NO, Output type: 1 current output 4 ... 20 mA , rising ramp, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC2500-F65-UE2R2-V15

Ultrasonic sensor
Level indication , 1 analog output, 0-10 V voltage source, 1 switch output, Series: F65, Rated operating voltage: 24 V DC, Operating voltage: 15 ... 30 V (including ripple)
In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0%, Output type: 1 switch output PNP, NO, Output type: 1 voltage output 0 ... 10 V , rising ramp, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V
 

UC400-F77-IU-IO-0,2M-V1

Ultrasonic sensor
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Cable connector M12 x 1 , 4-pin , L = 200 mm, Housing: Polycarbonate
 

UC400-F77-IU-IO-V31

Ultrasonic sensor
Single head system, IO-Link interface for parameterization, Programmable via DTM with PACTWARE, Selectable sound lobe width, Series: -F77, Operating voltage: 18 ... 30 V DC , ripple 10 %SS
, Output type: 1 analog output 0 (4) ... 20 mA or
1 analog output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M8 x 1 , 4-pin, Housing: Polycarbonate
 

UC4000-L2-E4-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E4, NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC4000-L2-E5-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC4000-L2-E7-V15

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, NO/NC, programmable, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC4000-L2-I-V15-Y263652

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC4000-L2-I-V15-Y305489

Ultrasonic sensor
Single head system, Sensor head bidirectional and rotatable, Function indicators visible from all directions, Quick mounting bracket, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: PA-GF35
 

UC4000-L2M-E6-T-2M

Ultrasonic sensor
Single head system, Extended temperature range, Cable connection, Rugged metal base, Series: -L2, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, UL approval: cULus Listed, General Purpose
Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Gọi điện thoại