| Item/ Model | E2V-X2 - - |
| Size | M12 |
| Sensing distance | 2mm±10% |
| Set distance | 0 to 1.6 mm |
| Differential travel | 10% max. of sensing distance |
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).) |
| Standard sensing object | Aluminum: 12 × 12 × 3 mm |
| Response frequency* | 150Hz |
| Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
| Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) |
| Control output Load current |
Open-collector output, 100 mA max. |
| Control Residual voltage output |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
| Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) |
| Operation mode | B1/C1 Models: NO B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
| Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor |
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) |
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) |
| Temperature influence |
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C |
| ±10% max. | |
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance | 50 MW min. (at 500 VDC) between current-carrying parts and case |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) |
| Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) |
| Weight (packed state) Cable | Approx. 120 g |
| Weight (packed state) Connector | Approx. 30 g |
| Weight (packed state) Pre-wired Connector Models | Approx. 50 g |
| Material Case | Nickel-plated brass |
| Material sensing surface | Heat-resistant ABS |
| Material Clamping nuts | Nickel-plated brass |
| Material Toothed whasher | Zinc-plated iron |
| Accessories | Instruction manual |
| Item/ Model | E2V-X4 - - |
| Size | M12 |
| Sensing distance | 4mm±10% |
| Set distance | 0 to 3.2 mm |
| Differential travel | 10% max. of sensing distance |
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).) |
| Standard sensing object | Aluminum: 12 × 12 × 3 mm |
| Response frequency* | 40Hz |
| Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
| Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) |
| Control output Load current |
Open-collector output, 100 mA max. |
| Control Residual voltage output |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
| Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) |
| Operation mode | B1/C1 Models: NO B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
| Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor |
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) |
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) |
| Temperature influence |
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C |
| ±15% max. | |
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance | 50 MW min. (at 500 VDC) between current-carrying parts and case |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) |
| Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) |
| Weight (packed state) Cable | Approx. 120 g |
| Weight (packed state) Connector | Approx. 30 g |
| Weight (packed state) Pre-wired Connector Models | Approx. 50 g |
| Material Case | Nickel-plated brass |
| Material sensing surface | Heat-resistant ABS |
| Material Clamping nuts | Nickel-plated brass |
| Material Toothed whasher | Zinc-plated iron |
| Accessories | Instruction manual |
| Item/ Model | E2V-X5 - - |
| Size | M18 |
| Sensing distance | 5mm±10% |
| Set distance | 0 to 4.0 mm |
| Differential travel | 10% max. of sensing distance |
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).) |
| Standard sensing object | Aluminum: 18 × 18 × 3 mm |
| Response frequency* | 70Hz |
| Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
| Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) |
| Control output Load current |
Open-collector output, 100 mA max. |
| Control Residual voltage output |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
| Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) |
| Operation mode | B1/C1 Models: NO B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
| Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor |
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) |
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) |
| Temperature influence |
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C |
| ±10% max. | |
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance | 50 MW min. (at 500 VDC) between current-carrying parts and case |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) |
| Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) |
| Weight (packed state) Cable | Approx. 150 g |
| Weight (packed state) Connector | Approx. 45 g |
| Weight (packed state) Pre-wired Connector Models | Approx. 70 g |
| Material Case | Nickel-plated brass |
| Material sensing surface | Heat-resistant ABS |
| Material Clamping nuts | Nickel-plated brass |
| Material Toothed whasher | Zinc-plated iron |
| Accessories | Instruction manual |
| Item/ Model | E2V-X8 - - |
| Size | M18 |
| Sensing distance | 8mm±10% |
| Set distance | 0 to 6.4 mm |
| Differential travel | 10% max. of sensing distance |
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).) |
| Standard sensing object | Aluminum: 24 × 24 × 3 mm |
| Response frequency* | 40Hz |
| Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
| Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) |
| Control output Load current |
Open-collector output, 100 mA max. |
| Control Residual voltage output |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
| Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) |
| Operation mode | B1/C1 Models: NO B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
| Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor |
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) |
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) |
| Temperature influence |
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C |
| ±15% max. | |
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance | 50 MW min. (at 500 VDC) between current-carrying parts and case |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) |
| Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) |
| Weight (packed state) Cable | Approx. 150 g |
| Weight (packed state) Connector | Approx. 45 g |
| Weight (packed state) Pre-wired Connector Models | Approx. 70 g |
| Material Case | Nickel-plated brass |
| Material sensing surface | Heat-resistant ABS |
| Material Clamping nuts | Nickel-plated brass |
| Material Toothed whasher | Zinc-plated iron |
| Accessories | Instruction manual |
| Item/ Model | E2V-X10 - - |
| Size | M30 |
| Sensing distance | 10mm±10% |
| Set distance | 0 to 8.0 mm |
| Differential travel | 10% max. of sensing distance |
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).) |
| Standard sensing object | Aluminum: 30 × 30 × 3 mm |
| Response frequency* | 70Hz |
| Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
| Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) |
| Control output Load current |
Open-collector output, 100 mA max. |
| Control Residual voltage output |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
| Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) |
| Operation mode | B1/C1 Models: NO B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
| Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor |
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) |
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) |
| Temperature influence |
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C |
| ±10% max. | |
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance | 50 MW min. (at 500 VDC) between current-carrying parts and case |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) |
| Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) |
| Weight (packed state) Cable | Approx. 200 g |
| Weight (packed state) Connector | Approx. 120 g |
| Weight (packed state) Pre-wired Connector Models | Approx. 140 g |
| Material Case | Nickel-plated brass |
| Material sensing surface | Heat-resistant ABS |
| Material Clamping nuts | Nickel-plated brass |
| Material Toothed whasher | Zinc-plated iron |
| Accessories | Instruction manual |
| Item/ Model | E2V-X15 - - |
| Size | M30 |
| Sensing distance | 15mm±10% |
| Set distance | 0 to 12.0 mm |
| Differential travel | 10% max. of sensing distance |
| Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).) |
| Standard sensing object | Aluminum: 45 × 45 × 3 mm |
| Response frequency* | 30Hz |
| Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
| Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) |
| Control output Load current |
Open-collector output, 100 mA max. |
| Control Residual voltage output |
2 V max. (Load current: 100 mA, Cable length: 2 m) |
| Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) |
| Operation mode | B1/C1 Models: NO B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
| Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor |
| Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) |
| Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) |
| Temperature influence |
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C |
| ±15% max. | |
| Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
| Insulation resistance | 50 MW min. (at 500 VDC) between current-carrying parts and case |
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions |
| Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) |
| Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) |
| Weight (packed state) Cable | Approx. 200 g |
| Weight (packed state) Connector | Approx. 120 g |
| Weight (packed state) Pre-wired Connector Models | Approx. 140 g |
| Material Case | Nickel-plated brass |
| Material sensing surface | Heat-resistant ABS |
| Material Clamping nuts | Nickel-plated brass |
| Material Toothed whasher | Zinc-plated iron |
| Accessories | Instruction manual |