Height |
95 mm |
Width |
71.2 mm |
Depth |
71.5 mm |
Horizontal pitch |
4 Div. |
Degree of protection |
IP20 (only when all terminal points are used) |
Ambient temperature (operation) |
-40 °C ... 80 °C |
Ambient temperature (storage/transport) |
-40 °C ... 80 °C |
Altitude |
≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) |
5 % ... 95 % |
Shock (operation) |
25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) |
5g (5 - 500 Hz/2.5 h/X, Y, Z) |
IEC test classification |
I + II |
|
T1 + T2 |
EN type |
T1 + T2 |
IEC power supply system |
TN-S |
|
TT |
Mode of protection |
L-N |
|
L-PE |
|
N-PE |
Mounting type |
DIN rail: 35 mm |
Color |
gray/blue |
|
black |
Housing material |
PBT |
Degree of pollution |
2 |
Flammability rating according to UL 94 |
V-0 |
Type |
DIN rail module, two-section, divisible |
Number of positions |
2 |
Arrester can be tested with CHECKMASTER from software version: |
From SW rev. 3.00 |
Surge protection fault message |
Optical, remote indicator contact |
Nominal voltage UN |
240 V AC (TN-S) |
|
240 V AC (TT) |
Nominal frequency fN |
50 Hz (60 Hz) |
Maximum continuous operating voltage UC (L-N) |
350 V AC |
Maximum continuous voltage UC (N-PE) |
350 V AC |
Rated load current IL |
125 A (< 55 °C) |
Residual current IPE |
≤ 0.01 mA |
Standby power consumption PC |
≤ 100 mVA |
Nominal discharge current In (8/20) µs (L-N) |
25 kA |
Nominal discharge current In (8/20) µs (L-PE) |
25 kA |
Nominal discharge current In (8/20) µs (N-PE) |
100 kA |
Impulse discharge current (10/350) µs (L-N), charge |
12.5 As |
Impulse discharge current (10/350) µs (L-N), specific energy |
160 kJ/Ω |
Impulse discharge current (10/350) µs (L-N), peak current value Iimp |
25 kA |
Impulse discharge current (10/350) µs (L-PE), charge |
12.5 As |
Impulse discharge current (10/350) µs (L-PE), specific energy |
160 kJ/Ω |
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp |
25 kA |
Impulse discharge current (10/350) µs (N-PE), charge |
50 As |
Impulse discharge current (10/350) µs (N-PE), specific energy |
2500 kJ/Ω |
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp |
100 kA |
Follow current interrupt rating Ifi (L-N) |
25 kA (264 V AC) |
|
3 kA (350 V AC) |
Follow current interrupt rating Ifi (N-PE) |
100 A (350 V AC) |
Short-circuit current rating ISCCR |
25 kA (264 V AC) |
|
3 kA (350 V AC) |
Voltage protection level Up (L-N) |
≤ 1.5 kV |
Voltage protection level Up (L-PE) |
≤ 2.2 kV |
Voltage protection level Up (N-PE) |
≤ 1.5 kV |
Residual voltage Ures (L-N) |
≤ 1.5 kV (at In) |
|
≤ 1.2 kV (at 10 kA) |
|
≤ 1 kV (at 5 kA) |
|
≤ 0.9 kV (at 3 kA) |
Residual voltage Ures (L-PE) |
≤ 2.2 kV (at In) |
|
≤ 2 kV (at 10 kA) |
|
≤ 1.8 kV (at 5 kA) |
|
≤ 1.6 kV (at 3 kA) |
Residual voltage Ures (N-PE) |
≤ 1.5 kV (at In) |
|
≤ 1 kV (at 10 kA) |
|
≤ 0.9 kV (at 5 kA) |
|
≤ 0.8 kV (at 3 kA) |
TOV behavior at UT (L-N) |
415 V AC (5 s / withstand mode) |
|
457 V AC (120 min / safe failure mode) |
TOV behavior at UT (N-PE) |
1200 V AC (200 ms / withstand mode) |
Response time tA (L-N) |
≤ 25 ns |
Response time tA (N-PE) |
≤ 100 ns |
Max. backup fuse with branch wiring |
315 A (gG) |
Max. backup fuse with V-type through wiring |
125 A (gG) |
Switching function |
PDT contact |
Operating voltage |
12 V AC ... 250 V AC |
|
125 V DC (200 mA DC) |
Operating current |
10 mA AC ... 1 A AC |
|
1 A DC (30 V DC) |
Connection method |
Plug-in/screw connection via COMBICON |
Screw thread |
M2 |
Tightening torque |
0.25 Nm |
Stripping length |
7 mm |
Conductor cross section flexible |
0.14 mm² ... 1.5 mm² |
Conductor cross section solid |
0.14 mm² ... 1.5 mm² |
Conductor cross section AWG |
28 ... 16 |
Connection method |
Screw terminal blocks |
Screw thread |
M5 |
Tightening torque |
4.5 Nm |
Stripping length |
18 mm |
Conductor cross section flexible |
2.5 mm² ... 25 mm² |
Conductor cross section solid |
2.5 mm² ... 35 mm² |
Conductor cross section AWG |
13 ... 2 |
SPD Type |
4CA |
Maximum continuous operating voltage MCOV (L-N) |
264 V AC |
Maximum continuous operating voltage MCOV (L-G) |
528 V AC |
Maximum continuous operating voltage MCOV (N-G) |
264 V AC |
Nom. voltage |
240 V AC |
Mode of protection |
L-N |
|
L-G |
|
N-G |
Power distribution system |
1S |
Nominal frequency |
50/60 Hz |
Measured limiting voltage MLV (L-N) |
1340 V |
Measured limiting voltage MLV (L-G) |
1550 V |
Measured limiting voltage MLV (N-G) |
1080 V |
Nominal discharge current In (L-N) |
20 kA |
Nominal discharge current In (L-G) |
20 kA |
Nominal discharge current In (N-G) |
20 kA |
REACh SVHC |
UV -328 25973-55-1 |
China RoHS |
Environmentally Friendly Use Period = 50 |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 4.0 |
27140201 |
eCl@ss 4.1 |
27130801 |
eCl@ss 5.0 |
27130801 |
eCl@ss 5.1 |
27130801 |
eCl@ss 6.0 |
27130808 |
eCl@ss 7.0 |
27130808 |
eCl@ss 8.0 |
27130808 |
eCl@ss 9.0 |
27130808 |
ETIM 2.0 |
EC001457 |
ETIM 3.0 |
EC001457 |
ETIM 4.0 |
EC001457 |
ETIM 5.0 |
EC001457 |
ETIM 6.0 |
EC001457 |
UNSPSC 6.01 |
30212010 |
UNSPSC 7.0901 |
39121610 |
UNSPSC 11 |
39121610 |
UNSPSC 12.01 |
39121610 |
UNSPSC 13.2 |
39121620 |