Thông tin nổi bật

Cảm biến chuyển động điều khiển đèn pha Merrytek MC090S E | Floodlight motion sensor

 

Basic Information

Place of Origin: Shenzhen
Brand Name: MERRYTEK
Certification: CE, TUV & RED
Model Number: MC090S E
Warranty: 5 years


 

Detail Information

- Operating Voltage Range: 198-264VAC 50/60Hz
Stand-by Power: <0.5W
Operating Frequency: 5.8 GHz ±74.9 MHz. ISM Wave Band
Hold Time: 5S/30S/1min/3min/5min/10min/20min/30min
Stand-by Period: 0s/10S/1min/3min/5min/10min/30min/+∞
Detection Area: 25%/50%/75%/100%
High Light: microwave sensors for lighting, floodlight motion sensor
 

Product Description

Cost-effective Microwave Motion Sensor with Patented Low Impedance Antenna MC090S E
 

Features

 1. Microwave motion detection version.

2. Eight DIP switch setting, distance, time, daylight sensor, multi-speed adjustable.

3. Ultra-small mounting size, multiple mounting options, support for top and bottom mounting options.

4. Super cost-effective, support a variety of lamps,tri-proof lamps, ceiling lamps.

5. The infrared sensor is used to filter out the light sensor, and the light sensitivity value is more accurate, and is not affected by cloudy and sunny days.

6. Low impedance 5.8G antenna for superior immunity to interference.

7. Batch over RED, TUV certification.


 

Parameter

Input
Operating Voltage Range: 198-264VAC 50/60Hz
DC Input Voltage: N/A
Rated Voltage: 220-240VAC 50/60Hz
No-load Power: ≤1.0W
Stand-by Power: ≤0.5W
Surge Test: Between L and N: 1KV

Output
Working Mode: ON/OFF
Type of Load: Resistive or Capacitive
Load Capacity: 800W (Resistive) or 400W (Capacitive)
Current of Load: N/A
Load surge current: 30A relay - 30A (test twidth 500us @230Vac at 50% Ipeak, cold start at full load) or 60A (test twidth 200us @230Vac at 50% Ipeak, cold start at full load)

Interface
1-10V dimmer: N/A
Synchronization control interface: N/A
High and Low Level Interface: N/A
PWM control interface: N/A
Interface terminal wiring mode: N/A


Sensor
Operating Frequency: 5.8 GHz ±74.9 MHz.ISM wave band
Transmitting power: 0.5mW Max.
Hold time: 5s/ 30s/ 60s/ 3min/ 5min/ 10min/ 20min/ 30min
DIM down: N/A
Cut off: N/A
Detection Area: 100% / 75% / 50% / 25%
Daylight Sensor: 2Lux/ 10Lux/ 25Lux/ 50Lux/ Disable
Daylight on/off: N/A
Detecting Radius: 4-7m (Installed at 3m high )
Mounting Height: 2.5-6 m(Suction Top Installation)
Detecting Angle: Ceiling mount 150°

Wireless module
Operating Frequency: N/A
Transmitting power: N/A
Transmission distance: N/A
Modulation mode: N/A
Coding group number: N/A

Operating Environment 
Operating Temperature: -20℃…+60℃ Humidity: 85% (non-condensing)
Storage Temperature: -40℃…+80℃
Certificate Standards: Safety standards EN61058-1
EMC standards: EN300440, EN301489-1, EN55015, EN61547, EN61000-3-2, EN61000-3-3, EN62479
Environmental Requirement: RoHS
Certificate: CE, TUV & RED

Others
Input/ output terminal specifications: 0.5-0.75mm2
IP Rating: IP20
Protection Class: Class II
Installation: Built-in installation
Dimension: 62*36*25mm
Package: Bubble bag + partition + outer box (K=A)
Net Weight: 36g
Lifetime: 50,000h @ Ta Full load

Note
1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s.
 

Function

On/OFF Function


With sufficient light, the lamp doesn't switch on.


With insufficient ambient light, the sensor switches on the lamp when motion is tectected


After hold time, the sensor switches off the lamp when no motion is detected
 

Dimension (mm)




 

Wiring


*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
 

Structure


 

Radiation Pattern

Ceiling mounting





*50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 25% sensitivity is not able to detect motion signal.
 

Wall mounting


 

Function Dialing Settings

Detection Area


Hold Time


Daylight Sensor


*When set to Disable gear, the sensor will turn on the light as long as the motion of the object is detected, regardless of whether the illumination is adequate or not.
 

Override Function

Quick switch ON/OFF 3 times within 2sec to override sensor function. Lights will switch on all the time. Power off and on again to recover sensor function.
 

Initialization

After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.
 

Factory settings

Detection Area: 100%, Hold Time: 5S, Daylight Sensor: Disable
 

Use Caution

1. Be sure to cut off the power supply before installing or adjusting the setting of the dial switch.
2. The microwave cannot pass through the metal, make sure there are no metal above the sensor.
3. It has to be at least 3.5mm away from metal around the microwave antenna. It is not allowed to place antenna and metal on the same horizontal.

Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Gọi điện thoại