Omron ZEN-10C3AR-A-V2 | Programmable Relay -Bộ lập trình điều khiển Relay Timer Counter Time switch 6AC/4Rly LCD 100-240VAC

Omron ZEN-10C3AR-A-V2 | Programmable Relay -Bộ lập trình điều khiển Relay Timer Counter Time switch 6AC/4Rly LCD 100-240VAC

503
Nhà sản xuất:

Omron

;   

Xuất xứ: Japan

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Bộ lập trình điều khiển Omron ZEN-10C3AR-A-V2 | Programmable Relay

(Relay Timer Counter Time switch 6AC/4Rly LCD 100-240VAC)

 

Features

Easy and Simple Programming for Automatic Small-scale Control

Saves Space, Wiring, and Installation Steps
- Versatile functionality in a compact body (70 mm wide × 90 mm high).
- This single Unit easily provides relay, timer, counter, and time switch functions. Wiring work is greatly reduced because separate wiring is not required for devices such as timers and counters.


Easy Programming
The LCD screen comes with 8 operation buttons on the front panel to enable programming in ladder view format. The LCD screen also has a backlight, making it easier to see when the ZEN is used in dark locations.

Note:
Not supported for ZEN-[]C2[][]-[]-V2 models.

Flexible Expansion Enables Up to 44 I/O Points
Up to three Expansion I/O Units can be connected if there are not enough I/O points. Expansion I/O Units are only 35 mm wide.

Note:
CPU Units with 10 I/O points can be expanded to 34 I/O points.
          Expansion I/O Units cannot be connected to Economy-type CPU Units.

Support Software with Simulation Function
- Programs can be easily written, saved, and monitored by personal computer.
- Programs can be simulated on the personal computer without connecting to the ZEN.

Note: 
For notebook computers that do not have an RS-232C serial port, connect the computer to the ZEN by connecting
          an OMRON CS1W-CIF31 USB-Serial Conversion Cable to the ZEN-CIF01 Connecting Cable.

Other Versatile Functions
- Use of a Memory Cassette makes it easy to copy and save programs.
- Equipped with two analog input channels (CPU Units with DC power supply only).
- Password function ensures security. *
- Multi-language display in six languages (English, Japanese, German, French, Spanish, Italian). *
- Display user-set messages or analog-converted values. *

* Not supported for ZEN-[]C2[][]-[]-V2 models.
 

Enhanced Features of V2 CPU Units

Improved Weekly Timer and Calendar Timer Functions
Note:
Not supported for ZEN-[]C2[][]-[]-V2 models.
- The time precision has been increased.
  Conventional model: 2-min difference/month
                                   ↓
  + V2 models: ±15-s difference/month (at 25°C)
- Multiple-day operation and pulse-output operation are now possible.
- These improved functions are convenient for time-controlled applications such as lighting and air conditioning control.


Economy-type Added to the Series
Economy-type CPU Units with a more affordable price have been added to the series, although Expansion I/O Units cannot be added.

12 to 24 VDC Line Voltage Operation
Operation is now possible with 12 VDC.

Expansion I/O Units have been reduced to half-size (35 mm wide).

RS-485 Communications Model Added to Series
Production line conditions can be remotely monitored by monitoring the ZEN control status.


More Precise Analog Input
Conventional model: ± 10% FS → -V2 models: ± 1.5% FS DC power supply models are equipped with two analog inputs (0 to 10 V). There are four analog comparators. The increased precision makes it even easier to use the Unit in simple control applications with voltage, current, temperature, and other analog values.

8-digit Counter, 150-Hz Counter
- An 8-digit counter and 8-digit comparator have been added.
- The maximum count for DC power supply models is 150 Hz.

Twin-timer Operation Added
Twin-timer operation allows you to set ON and OFF times separately, greatly simplifying intermittent operation.
 

Specifications

Rated supply voltage 100 to 240 VAC, 50/60 Hz
Operatingvoltage range 85 to 264 VAC
Power consumption 100 V AC: 5 VA max.
240 V AC: 7 VA max.
Inrush current 4.5 A max.
Ambient temperature 0 to 55°C (-25 to 55°C for ZEN-[]C2[][]-[]-V2 models)
Ambient storage temperature -20 to 75°C (-40 to 75°C for ZEN-[]C2[][]-[]-V2 models)
Ambient humidity 10% to 90% (with no condensation)
Ambient conditions No corrosive gases
Mounting method Surface mounting, DIN track mounting (standard (vertical) installation and horizontal installation) (See notes 1 and 2.)
Terminal block Solid-line terminal block (use solid wire or fine-stranded wire)
Terminal screw tightening torque 0.565 to 0.6 Nm (5 to 5.3 in-lb)
Degree of protection IP20 (Mounted inside a control panel)
 

Characteristics

Item Specification
Control method Stored program control
I/O control method Cyclic scan
Programming language Ladder diagram
Program capacity 96 lines (3 input conditions and 1 output per line)
Max. No. of control I/O
points
44 points *1
CPU Units with 20 I/O points: 12 inputs and 8 outputs
Expansion I/O Units: 4 inputs and 4 outputs each, up to 3 Units.
LCD display *2 12 characters × 4 lines, with backlight
Operation buttons *2 8 (4 cursor buttons and 4 operation buttons)
User program backup Internal EEPROM, Memory Cassette (optional)
Power interruption
hold
Internal holding bit status, holding timer/counter present values, calendar and clock (year,
month, day of month, day of week, time)
• Super capacitor backup time:2 days min. (25°C)
• Life of optional battery: 10 years min. (25°C)
Calendar and clock
function *2
Accuracy: ±15 s/month (at 25°C)
Timer accuracy 0.01 s unit: -0.05% -10 ms max. (rate for set value)
min/s unit: -0.05% -1 s max. (rate for set value)
h/min unit: -0.05% -1 min max. (rate for set value)
Maximum counting
speed
150 Hz: 8-Digit counter (F) set to high-speed operations (CPU Units with DC power supplies
only)
(The counting speed may be less than 150 Hz depending on the cycle time of the program.
See Data Sheet.)
Insulation resistance 20 MΩ (at 500 VDC) min.:
Between power supply terminals and all output terminals.
Between terminals of different output circuits.
Between all terminals of CPU Unit and all terminals of Expansion I/O Unit.
Insulation Reinforced insulation
Between power supply or input terminals and output terminals.
Between terminals of different output circuits.
Between all terminals of CPU Unit and all terminals of Expansion I/O Unit.
No separation
Between power supply and input terminals of the same unit.
Between power supply terminals of CPU Unit and computer connector,
Battery Unit connector, or all Expansion Unit connectors (all interfaces are live parts).
Dielectric strength 2,300 VAC, 50/60 Hz for 1 min (leakage current 1 mA max.):
Between power supply terminals and all output terminals.
Between terminals of different output circuit.
Between all terminals of CPU Unit and all terminals of Expansion I/O Unit.
Vibration resistance Conforms to IEC60068-2-6, 5 to 9 Hz with 3.5-mm single amplitude, 9 to 150 Hz
acceleration 9.8 m/s2, 10 sweeps each in X, Y, and Z directions (1 octave/min)
Shock resistance Conforms to IEC60068-2-27, 147 m/s2, 3 times each in X, Y, and Z directions.
Weight CPU Unit with 10 I/O points: Approx. 300 g max.
CPU Unit with 20 I/O points: Approx. 350 g max.
Expansion I/O Unit: Approx. 120 g max.

*1. Up to 34 points for CPU Units with 10 I/O points. With Communications-type CPU Units, however, the CPU Unit has 6 inputs and 3 outputs, for a maximum of 33 I/O points.

*2. Not provided for LED-type CPU Unit without display (i.e., ZEN-[]C2[][]-[]-V2 models).

 

Communications Specifications (Communications-type CPU Units)

Item ZEN-10C4[]R-[]-V2
Communications RS-485 (two-wire, half duplex)
Synchronization method Start-stop synchronization
Baud rate 4800, 9600, or 19200 bps
Transmission code ASCII
Data bit length 7 or 8 bits
Stop bit length 1 or 2 bits
Error detection Vertical parity (none, even, odd), Block check character (BCC)
Flow control None
Interface RS-485
Retry function None
Node number 0 to 99 (default: 1), XX (broadcasting)
  

Approved Standards

Item Specifications
Safety standards cULus: UL508/CSA C22.2 No.142 (ZEN-PA03024 take Class I Div2)
Conforms to EN/IEC 61131-2 clause 11, excluding 11.7.2.2
(Overvoltage category 2 and Pollution degree II conforms to IEC 60664-1)
EMC
(See note.)
Radiation Field Emission CISPR11 Class A, Group 1
Noise Terminal Voltage Emission CISPR11 Class A, Group 1
Electrostatic Discharge Immunity IEC61000-4-2 In air: 8 kV, In contact: 6 kV
Electromagnetic Field Immunity IEC61000-4-3 10 V/m
Electrical Fast Transient/Burst Immunity IEC61000-4-4
Power line
AC I/O: 2 kV
DC I/O: 1 kV
Surge Immunity IEC61000-4-5
Normal Noise
AC power supply, AC I/O: 1 kV
DC power supply, DC I/O: 0.5 kV
Common Noise
AC power supply, AC I/O: 2 kV
DC power supply: 1 kV
DC I/O: 0.5 kV
Immunity to Conducted Disturbances Induced by Radio-frequency Fields
IEC61000-4-6 3 V
Momentary Power Interruption Immunity IEC61131-2
CPU Units with AC Power Supplies: 10 ms max.
CPU Units with DC Power Supplies: 2 ms max. (level: PS1)

Note:
EMC conforms to EN 61131-2 clause 8 except in the following cases.
- When Expansion I/O Units with DC inputs are connected to a CPU Unit with an AC power supply, the burst immunity between power supplies will be 1 kv.
- When the signal wire for transistor outputs exceeds 10 m, the surge immunity of DC output signal lines will not conform.


Input Specifications

CPU Units

AC Inputs (Not Isolated)

Item Specifications Circuit drawing
Input voltage 100 to 240 VAC +10%, -15%, 50/60 Hz
Input impedance 680 kΩ
Input current 0.15 mA/100 VAC, 0.35 mA/240 VAC
ON voltage 80 VAC min.
OFF voltage 25 VAC max
ON response time 50 ms or 70 ms at 100 VAC (See note.)
100 ms or 120 ms at 240 VAC (See note.)
OFF response time

Note:
Can be selected using the filter settings.
 

DC Inputs: I0 to I3 for Units with 10 I/O points, I0 to I9 for Units with 20 I/O Points (Not Isolated)

Item Specifications Circuit drawing
Input voltage 12 to 24 VDC +20%, -10%
Input impedance 5.3 kΩ
Input current 4.5 mA (typ.)/24 VDC
ON voltage 8 VDC min.
OFF voltage 5 VDC max.
ON response time 15 ms or 50 ms (See note.)
OFF response time

Note:
Can be selected using the input filter settings, except when I0 is being used for an 8-digit counter with a high-speed input.
 

DC Inputs: I4 and I5 for Units with 10 I/O points, Ia and Ib for Units with 20 I/O Points (Not Isolated)

Item Specifications Circuit drawing
DC Inputs Input voltage 12 to 24 VDC +20%, -10%
Input impedance PNP: 5.5 kΩ/14 VDC min.
100 kΩ/14 VDC max.
NPN: 5.2 kΩ
Input current PNP: 4.3 mA (typ.)/24 VDC
NPN: 4.6 mA (typ.)/24 VDC
ON voltage 8 VDC min.
OFF voltage 3 VDC max.
ON response time 15 ms or 50 ms (See note.)
OFF response time
Analog
Inputs
Input range 0 to 10 V
External input impedance 100 kΩ min.
Resolution 0.1 V (1/100 FS)
Accuracy ±1.5% FS (at ambient operating temperature within rated range)
AD conversion data 0 to 10.5 V (in increments of 0.1 V)

Note:
Can be selected using the input filter settings.
 

Expansion I/O Units

AC Inputs (Not Isolated)

Item Specifications Circuit drawing
Input voltage 100 to 240 VAC +10%, -15%, 50/60 Hz
Input impedance 680 kΩ
Input current 0.15 mA/100 VAC, 0.35 mA/240 VAC
ON voltage 80 VAC min.
OFF voltage 25 VAC max.
ON response time 50 ms or 70 ms at 100 VAC (See note.)
100 ms or 120 ms at 240 VAC (See note.)
Off response time

Note:
Can be selected using the input filter settings.
 

DC Inputs (ZEN-8E1DR: Not Isolated, ZEN-8E1DT: Photocoupler Isolated)

Item Specifications Circuit drawing
Input voltage 12 to 24 VDC +20%, -10%
Input impedance 6.5 kΩ
Input current 3.7 mA (typ.)/24 VDC
ON voltage 8 VDC min.
OFF voltage 5 VDC max.
ON response time 15 ms or 50 ms (See note 1.)
OFF response time

Note:

1. Can be selected using the input filter settings.
2. The ZEN-8E1DT has no +/- terminals. There is no need to supply power.

 

Output Specifications (CPU Units and Expansion I/O Units)

Units with Relay Outputs

Item Specifications Circuit drawing
Maximum switching capacity 250 VAC/8 A (resistive load: cosΦ = 1)
24 VDC/5 A (resistive load)
Use the following values for the total of all outputs.
CPU Units with 10 I/O points: 20 A max.
(15 A max. for Communications-type CPU Units)
CPU Units with 20 I/O points: 40 A max.
Expansion I/O Units: 20 A max.
Minimum switching capacity 5 VDC/10 mA (resistive load)
Relay life Electrical Resistive load: 50,000 times (cosΦ = 1)
Inductive load: 50,000 times (cosΦ = 0.4)
Mechanical 10 million times
ON response time 15 ms max.
OFF response time 5 ms max.

The life under the worst conditions, of the output contacts used in ZEN relay outputs is given in the above table.
 

Note:
The switching capacity, switching durability, and applicable load area when actually using the relay depend on the
          type of load, environmental conditions, and switching conditions.
          Therefore, be sure to confirm these conditions for the actual machine before use.

 

Units with Transistor Outputs

Item Specifications Circuit drawing
Maximum switching capacity 24 VDC +20%, 500 mA  
Leakage current 0.1 mA max. Each circuit is configured with an independent common circuit
Residual voltage 1.5 V max.
ON response time 1 ms max.
OFF response time 1 ms max.


- Xem chi tiết Tài liệu kỹ thuật/ Datasheet Omron ZEN-10C3AR-A-V2 ở đây.


Tham khảo thêm các model khác cùng loại:

Model ZEN-10C1AR-A-V2

Unit CPU Units/ Name Standard LCD type/ No. of I/O points 10/ LCD display Yes/ Power supply voltage 100 to 240 VAC/ Inputs 6  100 to 240 VAC/ Outputs 4  Relays/ Buttons, calendar, and clock Yes/ Analog input No
 

Model ZEN-10C1DR-D-V2

Unit CPU Units/ Name Standard LCD type/ No. of I/O points 10/ LCD display Yes/ Power supply voltage 12 to 24 VDC/ Inputs 6  12 to 24 VDC/ Outputs 4  Relays/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-10C1DT-D-V2

Unit CPU Units/ Name Standard LCD type/ No. of I/O points 10/ LCD display Yes/ Power supply voltage 12 to 24 VDC/ Inputs 6  12 to 24 VDC/ Outputs 4  Transistors/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-20C1AR-A-V2

Unit CPU Units/ Name Standard LCD type/ No. of I/O points 20/ LCD display Yes/ Power supply voltage 100 to/ Inputs 12  100 to/ Outputs 8  Relays/ Buttons, calendar, and clock Yes/ Analog input No
 

Model ZEN-20C1DR-D-V2

Unit CPU Units/ Name Standard LCD type/ No. of I/O points 20/ LCD display Yes/ Power supply voltage 12 to/ Inputs 12  12 to/ Outputs 8  Relays/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-20C1DT-D-V2

Unit CPU Units/ Name Standard LCD type/ No. of I/O points 20/ LCD display Yes/ Power supply voltage 24 VDC/ Inputs 12  24 VDC/ Outputs 8  Transistors/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-10C2AR-A-V2

Unit CPU Units/ Name LED type without display *1/ No. of I/O points 10/ LCD display No/ Power supply voltage 100 to 240 VAC/ Inputs 6  100 to 240 VAC/ Outputs 4  Relays/ Buttons, calendar, and clock No/ Analog input No
 

Model ZEN-10C2DR-D-V2

Unit CPU Units/ Name LED type without display *1/ No. of I/O points 10/ LCD display No/ Power supply voltage 12 to 24 VDC/ Inputs 6  12 to 24 VDC/ Outputs 4  Relays/ Buttons, calendar, and clock No/ Analog input Yes
 

Model ZEN-10C2DT-D-V2

Unit CPU Units/ Name LED type without display *1/ No. of I/O points 10/ LCD display No/ Power supply voltage 12 to 24 VDC/ Inputs 6  12 to 24 VDC/ Outputs 4  Transistors/ Buttons, calendar, and clock No/ Analog input Yes
 

Model ZEN-20C2AR-A-V2

Unit CPU Units/ Name LED type without display *1/ No. of I/O points 20/ LCD display No/ Power supply voltage 100 to 240 VAC/ Inputs 12  100 to 240V AC/ Outputs 8  Relays/ Buttons, calendar, and clock No/ Analog input No
 

Model ZEN-20C2DR-D-V2

Unit CPU Units/ Name LED type without display *1/ No. of I/O points 20/ LCD display No/ Power supply voltage 12 to 24 VDC/ Inputs 12  12 to 24 VDC/ Outputs 8  Relays/ Buttons, calendar, and clock No/ Analog input Yes
 

Model ZEN-20C2DT-D-V2

Unit CPU Units/ Name LED type without display *1/ No. of I/O points 20/ LCD display No/ Power supply voltage 12 to 24 VDC/ Inputs 12  12 to 24 VDC/ Outputs 8  Transistors/ Buttons, calendar, and clock No/ Analog input Yes
 

Model ZEN-10C3AR-A-V2

Unit CPU Units/ Name Economy type (Expansion I/O Units cannot be connected)/ No. of I/O points 10/ LCD display Yes/ Power supply voltage 100 to 240 VAC/ Inputs 6  100 to 240 VAC/ Outputs 4  Relays/ Buttons, calendar, and clock Yes/ Analog input No
 

Model ZEN-10C3DR-D-V2

Unit CPU Units/ Name Economy type (Expansion I/O Units cannot be connected)/ No. of I/O points 10/ LCD display Yes/ Power supply voltage 12 to/ Inputs 6  12 to 24 VDC/ Outputs 4  Relays/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-20C3AR-A-V2

Unit CPU Units/ Name Economy type (Expansion I/O Units cannot be connected)/ No. of I/O points 20/ LCD display Yes/ Power supply voltage 100 to/ Inputs 12  100 to/ Outputs 8  Relays/ Buttons, calendar, and clock Yes/ Analog input No
 

Model ZEN-20C3DR-D-V2

Unit CPU Units/ Name Economy type (Expansion I/O Units cannot be connected)/ No. of I/O points 20/ LCD display Yes/ Power supply voltage 12 to/ Inputs 12  12 to/ Outputs 8  Relays/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-10C4AR-A-V2

Unit CPU Units/ Name Communi-type/ No. of I/O points 9/ LCD display Yes/ Power supply voltage 100 to/ Inputs 6  100 to/ Outputs 3  Relays/ Buttons, calendar, and clock Yes/ Analog input No
 

Model ZEN-10C4DR-D-V2

Unit CPU Units/ Name Communi-type/ No. of I/O points 9/ LCD display Yes/ Power supply voltage 12 to/ Inputs 6  12 to/ Outputs 3  Relays/ Buttons, calendar, and clock Yes/ Analog input Yes
 

Model ZEN-KIT01-EV4 *4

Unit ZEN Kit/ Name Communi-type/ No. of I/O points Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual./ LCD display Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual./ Power supply voltage Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual./ Inputs Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual.  Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual./ Outputs Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual.  Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual./ Buttons, calendar, and clock Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual./ Analog input Set containing CPU Unit (ZEN-10C1AR-A-V2), Connecting Cable, ZEN Support Software, and manual.
 

Model ZEN-KIT02-EV4 *4

Unit ZEN Kit/ Name Communi-type/ No. of I/O points Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual./ LCD display Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual./ Power supply voltage Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual./ Inputs Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual.  Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual./ Outputs Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual.  Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual./ Buttons, calendar, and clock Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual./ Analog input Set containing CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software, and manual.
 

Model ZEN-8E1AR *2 *3

Unit Expansion I/O Units/ Name  / No. of I/O points 8/ LCD display ---/ Power supply voltage 100 to/ Inputs 4  100 to/ Outputs 4  Relays/ Buttons, calendar, and clock ---/ Analog input ---
 

Model

Unit Expansion I/O Units/ Name  / No. of I/O points 8/ LCD display ---/ Power supply voltage 240 VAC/ Inputs 4  240 VAC/ Outputs 4  Relays/ Buttons, calendar, and clock ---/ Analog input ---
 

Model ZEN-8E1DR *2

Unit Expansion I/O Units/ Name  / No. of I/O points 8/ LCD display ---/ Power supply voltage 12 to/ Inputs 4  12 to/ Outputs 4  Relays/ Buttons, calendar, and clock ---/ Analog input ---
 

Model

Unit Expansion I/O Units/ Name  / No. of I/O points 8/ LCD display ---/ Power supply voltage 24 VDC/ Inputs 4  24 VDC/ Outputs 4  Relays/ Buttons, calendar, and clock ---/ Analog input ---
 

Model ZEN-8E1DT *2

Unit Expansion I/O Units/ Name  / No. of I/O points 8/ LCD display ---/ Power supply voltage ---/ Inputs 4   / Outputs 4  Transistors/ Buttons, calendar, and clock ---/ Analog input ---
Sản phẩm cùng loại
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Tụ chống sét Varistor (MOVs)là gì? Nguyên lý hoạt động (Wiki)Tụ chống sét ( Varistor hoặc Metal Varistor Oxit (MOV)) là một điện trở đặc biệt được sử dụng để bảo vệ mạch điện chống lại sự đột biến điện áp
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
Sensors In Agriculture (Comming soon)Sensors In Agriculture. Soil moisture sensors, Agricultural temperature sensors, GPS sensors, Weather sensors, Crop health sensors, Electronic sensors, Light
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại