Cảm biến mức siêu âm Siemens 7ML5110-1DD07-4AF3 | SITRANS Probe LU240 Ultrasonic level transmitter
(12m HART 4-20mA đo đo mức, âm lượng và lưu lượng thể tích cho chất lỏng, bùn và vật liệu rời)
Product |
Article Number (Market Facing Number) |
7ML5110-1DD07-4AF3 |
Product Description |
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft). . Communications: HART (4 ... 20 mA) level, volume, volume flow Ingress protection: IP66, IP68, TYPE 4X, 6 Measurement range/ wetted parts: 200 ... 6000 mm (7.87 ... 236.22 inch), PVDF Copolymer Process connection: 2" NPT [(Taper), ASME B1.20.1] . Non wetted parts: Plastic (PBT/PC material) Enclosure Type of protection: Non Ex (ordinary locations) cCSAus, CE, UKCA, KC, RCM, EAC Electrical connections/ cable entries: 2 x M20 x 1.5 (one general purpose Polyamide cable gland and one Polyamide blocking plug provided) Local HMI: With display (clear lid of PC material) |
Product family |
SITRANS Probe LU240 |
Product Lifecycle (PLM) |
PM300:Active Product |
Price data |
Price Group / Headquarter Price Group |
8L1 |
List Price (w/o VAT) |
Show prices |
Customer Price |
Show prices |
Metal Factor |
None |
Delivery information |
Export Control Regulations |
ECCN : EAR99 / AL : N |
Factory Production Time |
1 Day/Days |
Net Weight (kg) |
1.250 Kg |
Package size unit of measure |
Not available |
Quantity Unit |
1 Piece |
Packaging Quantity |
1 |
Additional Product Information |
EAN |
Not available |
UPC |
Not available |
Commodity Code |
9031800090 |
LKZ_FDB/ CatalogID |
FI01-4 |
Product Group |
4710 |
Group Code |
R3P5 |
Country of origin |
Canada |
Compliance with the substance restrictions according to RoHS directive |
Since: 2003.01.10 |
Product class |
C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
WEEE (2012/19/EU) Take-Back Obligation |
Yes |
REACH Art. 33 Duty to inform according to the current list of candidates |
|
Classifications |
|
|
Version |
Classification |
eClass |
1.2 |
27-20-05-06 |
eClass |
6 |
27-20-05-06 |
eClass |
7.1 |
27-20-05-06 |
eClass |
8 |
27-20-05-06 |
eClass |
9 |
27-20-05-06 |
eClass |
9.1 |
27-20-05-06 |
|
Tham khảo các Thành phần khác liên quan:
7ML5110-1DD07-4CF3-Z E31
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft). . Communications: HART (4 ... 20 mA) level, volume, volume flow Ingress protection: IP66, IP68, TYPE 4X, 6 Measurement range/ wetted parts: 200 ... 6000 mm (7.87 ... 236.22 inch), PVDF Copolymer Process connection: 2" NPT [(Taper), ASME B1.20.1] . Non wetted parts: Plastic (PBT/PC material) Enclosure Type of protection: Ex i (ia) (Ex-Zone 0/Div 1) /IS, FM NI (Class I, Div 2) Electrical connections/ cable entries: 2 x M20 x 1.5 (one general purpose Polyamide cable gland and one Polyamide blocking plug provided) Local HMI: With display (clear lid of PC material) Approvals: ATEX II 1G Ex ia IIC T4 Ga, Ta= -40ºC...+80ºC; UKEX II 1G Ex ia IIC T4 Ga, Ta= -40ºC...+80ºC; IECEx Ex ia IIC T4 Ga, Ta = -40ºc...+80ºC; EAC Ex 0Ex ia IIC T4 Ga, IP67/IP68; SABA Ex ia IIC T4 Ga, Ta = -40ºC...+80ºC
7ME3480-3AE00-2BD1
SITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 10 L/Pulse, max. flow rate 3600 m3/h (with option L05: 10 gal/p., max. flow rate 60000 GPM). For combined heating/cooling, Flowmeter placed at hot temperture (MID conform for heating). Without sensor, Set-up: PT500 No thermowells included. Power supply Mains powered with 230 VAC module (incl. back-up battery). Module 1 M-Bus. MWh, kW, m3, m3/h - 1 digit resolution. Calculator variant for China according to EU type approval Suitable for billing of heat quantities (also combined) if national approvals exist. Not for use in Europe.
7MC5512-1JA04-0HA1-Z E54+T10+Y01+Y44
Temperature sensor SITRANS TS500 with welded thermowell 316L Process connection: NPT 1/2" thread; for TW type 2N/2G/3G Thermowell form: Form 2/2G/2F; 9mm Insertion length " mm " : 141...160 Initial: 160 Extension: Without Neck Type 2/2N Head type: AH0; Aluminum; suitable for Ex d; Display; IP screw-in lid; Type AH0 Meas. range:- 50...400DegC.; Sensor:1xPt 100 Cl. B IEC 60751; BA Explosion protection (NEPSI) For China Requirements non-Ex Transmitter: TH100; Pt 100; 4-20mA configurable Transmitter options: Specify customized measuring range in plain text Length options: specify special insertion length "U" ( within specified range) in plain text
7ME3570-1JA40-0FQ1-Z S30
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Meter power: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 304 - 9144 mm (12 - 360"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, Ulc, CE Enable Mass storage device function for SD-card by USB (outside USA mandatory)
7ME5610-4HC15-2AA1
SITRANS FM Transmag 911/E Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 1000 (1/2" to 40"), AC-excited. Suitable for volume flow measurement of liquids (conductive), for use in heavy-duty applications like pulp & paper stock over 3%, mining slurries with magnetic particles. Remote DN150, 6 Inch EN 1092-1, PN 16 (DN 65 - 1000 (2 1/2 Inch - 40 Inch)) Flange material: Mild steel 1.0460 / 1.0570) Liner material: Linatex Hastelloy C276 / 2.4819 . . Metric:Polyamid Terminalbox
7ML5110-1DD07-4AF3
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft).
7ML5110-1DD07-4AK3
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft).
7ML5110-1GD07-4AK3
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft).
7ML51..-.....-....
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft).
7ML5110-1DE07-4AF3
SITRANS Probe LU240 Ultrasonic level transmitter ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (40 ft).
7ML5110-1DD07-4BK3