Bộ cách ly tín hiệu Phoenix Contact MACX MCR-SL-RPSS-2I-2I | 2904089
Thông số kỹ thuật
Đặc tính sản phẩm
Product type |
Repeater power supplies |
Application |
Analog IN |
No. of channels |
2 |
Type |
Signal conditioners with SIL and PL Functional Safety |
Insulation characteristics |
Overvoltage category |
II |
Pollution degree |
2 |
Thông số về điện
No. of channels |
2 |
Signal transmission behavior |
In = Out |
Step response (10-90%) |
< 1.3 ms (for 4 mA ... 20 mA step) |
Maximum temperature coefficient |
< 0.01 %/K |
Maximum transmission error |
< 0.1 % (of final value) |
Transmission error, typical |
< 0.05 % (of final value) |
Electrical isolation Input/output, power supply |
Rated insulation voltage |
300 Vrms |
Test voltage |
2.5 kV AC (50 Hz, 60 s) |
Insulation |
Safe isolation in accordance with IEC/EN 61010-1 |
Electrical isolation Output 1/output 2/ power supply |
Test voltage |
1.5 kV AC (50 Hz, 60 s) |
Supply |
Nominal supply voltage |
24 V DC |
Supply voltage range |
19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) |
Max. current consumption |
< 100 mA (24 V / 20 mA) |
Power dissipation |
< 1.4 W (at 24 V DC / 20 mA) |
Thông số đầu vào
Signal: Current |
Number of inputs |
2 |
Current input signal |
4 mA ... 20 mA |
Transmitter supply voltage |
> 16 V (20 mA) |
Underload/overload signal range |
0 mA ... 24 mA |
Thông số đầu ra
Signal |
Output description |
Current output |
Number of outputs |
2 |
Current output signal |
4 mA ... 20 mA (active) |
Load/output load current output |
≤ 450 Ω (20 mA) |
≤ 375 Ω (24 mA) |
Output behavior in the event of an error |
< 3.6 mA (In the event of cable break at the input (as per NE 43)) |
> 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) |
Underload/overload signal range |
0 mA ... 24 mA |
Thông số kết nối
Connection method |
Screw connection |
Stripping length |
7 mm |
Screw thread |
M3 |
Conductor cross section solid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Tightening torque |
0.5 Nm ... 0.6 Nm |
Thông số giao diện
Data communication (bypass) |
HART function |
Yes |
Protocols supported |
HART-transparent |
Thông số đèn LED tín hiệu
Status display |
Green LED (supply voltage) |
Thông số kích thước
Width |
12.5 mm |
Height |
112.5 mm |
Depth |
113.7 mm |
Depth NS 35/7,5 |
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Thông số đặc tính cơ học
Flammability rating according to UL 94 |
V0 (Housing) |
Housing material |
PA 6.6-FR |
Thông số môi trường hoạt động và Cấp bảo vệ
Ambient conditions |
Degree of protection |
IP20 (not assessed by UL) |
Ambient temperature (operation) |
-40 °C ... 70 °C (Any mounting position) |
Ambient temperature (storage/transport) |
-40 °C ... 80 °C |
Altitude |
≤ 2000 m |
Permissible humidity (operation) |
10 % ... 95 % (non-condensing) |
Approval data
CE |
Certificate |
CE-compliant |
Note |
and EN 61326 |
ATEX |
Identification |
II 3 G Ex nA IIC T4 Gc X |
UKCA Ex (UKEX) |
Identification |
II 3 G Ex nA IIC T4 Gc |
Certificate |
PxCIF21UKEX2904089X |
UL, USA / Canada |
Identification |
UL 508 Listed |
UL 61010 Listed |
Class I, Div. 2, Groups A, B, C, D T4 |
Class I, Zone 2, Groups IIC, IIB, IIA T4 |
UL, USA / Canada |
Identification |
UL 61010 Listed |
Class I, Div. 2, Groups A, B, C, D T4 |
Class I, Zone 2, Group IIC T4 |
Shipbuilding approval |
Certificate |
DNV GL TAA000020C |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
2 |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
3 |
Certificate |
BVS PB 04-13 |
Performance Level (ISO 13849) |
Identification |
d |
Systematic Capability |
Identification |
3 |
DNV GL data |
Temperature |
B |
Humidity |
B |
Vibration |
A |
EMC |
A |
Enclosure |
Required protection according to the Rules shall be provided upon installation on board |
EMC data
Electromagnetic compatibility |
Conformance with EMC directive |
Noise emission |
EN 61000-6-4 |
Noise immunity |
EN 61000-6-2 |
Note |
When being exposed to interference, there may be minimal deviations. |
Lắp đặt
Mounting type |
DIN rail mounting |
Thông số thương mại
Item number |
2904089 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product Key |
CK1111 |
Catalog Page |
Page 123 (C-5-2019) |
GTIN |
4046356772792 |
Weight per Piece (including packing) |
243 g |
Weight per Piece (excluding packing) |
140 g |
Customs tariff number |
85437090 |
Country of origin |
DE |
- Tài liệu kỹ thuật Phoenix Contact MACX MCR-SL-RPSS-2I-2I | 2904089
ở đây.
Tham khảo thêm các model khác cùng loại:
Temperature measuring transducer
MACX MCR-T-UI-UP - 2811394
Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Power/input isolating amplifier
MACX MCR-EX-SL-RPSSI-I - 2865340
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. 3-way electrical isolation, SIL 2 in accordance with IEC 61508, with screw connection
Isolation amplifier
MACX MCR-EX-SL-2NAM-RO-SP - 2924087
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Power/input isolating amplifier
MACX MCR-EX-SL-RPSSI-I-SP - 2924016
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. 3-way electrical isolation, SIL 2 in accordance with IEC 61508, with Push-in connection
Signal conditioner
MACX MCR-UI-UI-NC - 2811446
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.
Programming adapter
IFS-USB-PROG-ADAPTER - 2811271
Programming adapter with USB interface, for programming with software. The USB driver is included in the software solutions for the products to be programmed, such as measuring transducers or motor managers.
Power and error message module
MACX MCR-PTB-SP - 2924184
Power and fault signaling module with Push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector
Isolation amplifier
MACX MCR-EX-SL-NAM-2RO-SP - 2924061
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Temperature measuring transducer
MACX MCR-T-UIREL-UP - 2811378
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Loop-powered isolators
MACX MCR-SL-I-I-ILP - 2905278
1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
Isolation amplifier
MACX MCR-EX-SL-2NAM-RO - 2865476
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Power/input isolating amplifier
MACX MCR-SL-RPSSI-I - 2865955
Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 in accordance with IEC 61508.
Signal isolator
MACX MCR-EX-SL-RPSS-2I-2I - 2865382
Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, screw connection, up to SIL 3, PL.
Isolation amplifier
MACX MCR-EX-SL-NAM-2T-SP - 2924074
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Repeater power supply
MACX MCR-SL-RPSSI-I-UP - 2865968
Repeater power supply for supplying 2- and 3-conductor transmitters with Hart transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), screw connection
Signal conditioner
MACX MCR-UI-UI-UP-NC - 2811297
Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.
Repeater power supply
MACX MCR-SL-RPSSI-2I - 2924825
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.
Temperature measuring transducer
MACX MCR-EX-1TS-I-OLP - 1145365
Ex i, Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Screw connection
Isolation amplifier
MACX MCR-EX-SL-NAM-R - 2865434
Ex i NAMUR signal conditioner. For operating proximity sensors and switches in a potentially explosive area. The signals are transmitted by a relay output (changeover contact) to a safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Isolation amplifier
MACX MCR-SL-NAM-2RO - 2865010
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, screw connection.
Isolation amplifier
MACX MCR-EX-SL-NAM-2RO - 2865450
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Output signal conditioner
MACX MCR-EX-IDS-I-I - 2908060
Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.
Isolation amplifier
MACX MCR-EX-SL-2NAM-T - 2865489
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Repeater power supply
MACX MCR-SL-RPSSI-I-UP-SP - 2924210
Repeater power supply for supplying 2- and 3-conductor transmitters with HART transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), Push-in connection
Temperature measuring transducer
MACX MCR-EX-RTD-I - 1050222
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, SIL, screw connection, standard configuration.
Temperature measuring transducer
MACX MCR-EX-RTD-I-SP - 1050252
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, standard configuration.
Temperature measuring transducer
MACX MCR-RTD-I - 1050192
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.
Temperature measuring transducer
MACX MCR-1TS-I-OLP - 1145192
Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Screw connection
Signal isolator
MACX MCR-EX-SL-RPSS-2I-2I-SP - 2924676
Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL.
Temperature measuring transducer
MACX MCR-T-UI-UP-C - 2811873
Freely programmable temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Isolation amplifier
MACX MCR-SL-2NAM-RO - 2865049
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
Isolation amplifier
MACX MCR-EX-SL-2NAM-R-UP - 2865984
2-channel Ex i NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Fault detection (LFD), 3-way isolation, SIL 2.
Loop-powered isolators
MACX MCR-SL-2I-2I-ILP - 2905280
2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
Isolation amplifier
MACX MCR-SL-2NAM-RO-SP - 2924294
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Isolation amplifier
MACX MCR-SL-2NAM-R-UP-SP - 2924304
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
Limit value switches
MACX MCR-SL-UI-REL - 2906169
Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.
Output signal conditioner
MACX MCR-EX-IDS-I-I-SP - 2908062
Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
Signal conditioner
MACX MCR-UI-UI - 2811284
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL.
Temperature measuring transducer
MACX MCR-EX-T-UI-UP-SP - 2924689
Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Temperature measuring transducer
MACX MCR-T-UIREL-UP-SP - 2811828
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
HART transfer board
MACX MCR-S-MUX-TB - 2308124
The HART transfer board is used to operate the MACX-MCR-S-MUX HART multiplexer. The signals from the HART-compatible signal converters are applied to the terminal strip of the transfer board where they are then transmitted to the multiplexer via an FLK.
Signal isolator
MACX MCR-SL-RPSS-2I-2I-SP - 2904090
2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, Push-in connection, SIL, PL.
Isolation amplifier
MACX MCR-SL-NAM-R - 2865997
NAMUR signal conditioners for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with screw connection.
Repeater power supply
MACX MCR-EX-SL-RPSSI-2I-SP - 2924236
Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4 mA ... 20 mA electrical isolation signals from the Ex area to two loads in the safe area. 4-way electrical isolation, Push-in connection, SIL, PL.
Signal conditioner
MACX MCR-UI-UI-UP-SP-NC - 2811569
Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), spring-cage connection, SIL.
Solenoid driver
MACX MCR-EX-SL-SD-21-40-LP-SP - 2924139
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
Signal conditioner
MACX MCR-UI-UI-UP - 2811459
Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL.
Isolation amplifier
MACX MCR-SL-2NAM-R-UP - 2865052
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, screw connection, SIL 2.
Repeater power supply
MACX MCR-EX-SL-RPSSI-2I - 2865366
Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4…20 mA electrically isolated signals from the Ex area to two loads in the safe area. 4-way electrical isolation, screw connection, SIL, PL.
Isolation amplifier
MACX MCR-SL-NAM-2RO-SP - 2924265
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection.
Solenoid driver
MACX MCR-EX-SL-SD-21-60-LP-SP - 2924100
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Push-in connection.
Isolation amplifier
MACX MCR-EX-SL-NAM-2T - 2865463
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Temperature measuring transducer
MACX MCR-RTD-I-SP - 1050201
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.
Signal conditioner
MACX MCR-UI-UI-SP-NC - 2811556
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), spring-cage connection, SIL.
Limit value switches
MACX MCR-SL-UI-REL-SP - 2906170
Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.
Isolation amplifier
MACX MCR-SL-NAM-2T - 2865023
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
Temperature measuring transducer
MACX MCR-T-UI-UP-SP - 2811860
Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Temperature measuring transducer
MACX MCR-EX-T-UI-UP - 2865654
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Signal isolator
MACX MCR-SL-RPSS-2I-2I - 2904089
2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, screw connection, SIL, PL.
Solenoid driver
MACX MCR-EX-SL-SD-23-48-LFD - 2924867
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 in accordance with IEC 61508, screw connection
Power and error message module
MACX MCR-PTB - 2865625
Power and fault signaling module with screw connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector
Isolation amplifier
MACX MCR-EX-SL-NAM-R-SP - 2924045
Ex i NAMUR signal conditioner. For operating proximity sensors and switches in a potentially explosive area. The signals are transmitted by a relay output (changeover contact) to a safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Isolation amplifier
MACX MCR-SL-2NAM-T - 2865036
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
Isolation amplifier
MACX MCR-EX-SL-2NAM-T-SP - 2924090
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Loop-powered isolators
MACX MCR-SL-I-I-HV-ILP-SP - 2907705
1-channel input loop-powered 2-way isolator with increased isolating voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Loop-powered isolators
MACX MCR-SL-2I-2I-HV-ILP-SP - 2907707
Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Repeater power supply
MACX MCR-SL-RPSSI-2I-SP - 2924838
Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 mA … 20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL.
Isolation amplifier
MACX MCR-EX-SL-2NAM-R-UP-SP - 2924249
2-channel Ex i NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Fault detection (LFD), 3-way isolation, SIL 2.
Solenoid driver
MACX MCR-EX-SL-SD-24-48-LP-SP - 2924126
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
Power/input isolating amplifier
MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. SIL 2 (1oo1) / SIL 3 (1oo2), wide-range supply.
Solenoid driver
MACX MCR-EX-SL-SD-24-48-LP - 2865609
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
Output signal conditioner
MACX MCR-EX-IDS-2I-2I - 2865421
2-channel Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection.
Loop-powered isolators
MACX MCR-SL-I-I-HV-ILP - 2907704
1-channel input loop-powered 2-way isolator with increased isolating voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.
Output signal conditioner
MACX MCR-IDS-I-I-SP - 2908064
Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
DIN rail bus connectors
ME 6,2 TBUS-PR-ADAPTER - 1136500
Power rail adapter (ME 6,2 TBUS-PR-ADAPTER), 2-pos., enables MINI and MACX Analog modules to be adapted for supply via universal power rail UPR-03 and UPR-05.
Isolation amplifier
MACX MCR-SL-NAM-R-SP - 2924252
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with Push-in connection.
Loop-powered isolators
MACX MCR-SL-I-I-ILP-SP - 2905279
1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
HART multiplexer
MACX MCR-S-MUX - 2865599
HART Multiplexer for online configuration and diagnostics of HART-compatible field devices, as well as for continuous documentation of process variables and states with a PC or management system for mounting on NS 35/7.5 or NS 32
Solenoid driver
MACX MCR-EX-SL-SD-21-25-LP-SP - 2924113
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
Temperature measuring transducer
MACX MCR-EX-1TS-I-OLP-SP - 1145207
Ex i, Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Push-in connection
Solenoid driver
MACX MCR-EX-SL-SD-21-60-LP - 2865515
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Screw connection.
Solenoid driver
MACX MCR-EX-SL-SD-21-25-LP - 2865492
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
Temperature measuring transducer
MACX MCR-EX-TC-I-C - 1052458
Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Order configuration, freely programmable. 3-way isolation, SIL.
Temperature measuring transducer
MACX MCR-EX-T-UIREL-UP-SP-C - 2924809
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Temperature measuring transducer
MACX MCR-RTD-I-C - 1052472
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, order configuration.
Temperature measuring transducer
MACX MCR-EX-TC-I - 1050233
Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, screw connection, SIL.
Isolation amplifier
MACX MCR-EX-SL-NAM-NAM - 2866006
Ex i NAMUR signal conditioner for operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive in accordance with EN 60947-5-6), line fault transparency, up to SIL 2 in accordance with IEC 61508, screw connection
Loop-powered isolators
MACX MCR-SL-2I-2I-HV-ILP - 2907706
Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology
Temperature measuring transducer
MACX MCR-RTD-I-SP-C - 1052464
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, order configuration.
Temperature measuring transducer
MACX MCR-T-UI-UP-SP-C - 2811970
Freely programmable temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Signal conditioner
MACX MCR-UI-UI-UP-SP - 2811585
Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL.
Temperature measuring transducer
MACX MCR-EX-RTD-I-C - 1052463
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, SIL, screw connection, order configuration.
Output signal conditioner
MACX MCR-EX-IDS-2I-2I-SP - 2904931
2-channel Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
Temperature measuring transducer
MACX MCR-1TS-I-OLP-SP - 1145196
Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Push-in connection
Temperature measuring transducer
MACX MCR-EX-T-UIREL-UP-C - 2865722
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Loop-powered isolators
MACX MCR-SL-2I-2I-ILP-SP - 2905281
2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Temperature measuring transducer
MACX MCR-T-UIREL-UP-SP-C - 2811831
Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Solenoid driver
MACX MCR-EX-SL-SD-21-40-LP - 2865764
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
Temperature measuring transducer
MACX MCR-EX-RTD-I-SP-C - 1052652
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, order configuration.
Repeater power supply
MACX MCR-EX-SL-RPSSI-2I-1S - 2908855
Ex i measuring transducer repeater power supply and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active electrically isolated signals from the Ex area to two loads. SIL 2 in accordance with IEC 61508, screw connection.
Isolation amplifier
MACX MCR-SL-2NAM-T-SP - 2924281
NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Limit value switches
MACX MCR-EX-SL-UI-REL-SP - 2906165
Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.
Temperature measuring transducer
MACX MCR-TC-I-C - 1052459
Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Order configuration, freely programmable, 3-way electrical isolation, screw connection, SIL.
Temperature measuring transducer
MACX MCR-EX-T-UI-UP-SP-C - 2924692
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Repeater power supply
MACX MCR-EX-SL-RPSSI-2I-1S-SP - 2908856
Ex i measuring transducer repeater power supply and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active electrically isolated signals from the Ex area to two loads. SIL 2 in accordance with IEC 61508, Push-in connection.
Isolation amplifier
MACX MCR-SL-NAM-2T-SP - 2924278
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Limit value switches
MACX MCR-EX-SL-UI-REL - 2906164
Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.
Temperature measuring transducer
MACX MCR-EX-T-UIREL-UP-SP - 2924799
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Output signal conditioner
MACX MCR-IDS-2I-2I-SP - 2908066
2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
Temperature measuring transducer
MACX MCR-TC-I - 1050228
Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Freely programmable, 3-way electrical isolation, screw connection, SIL.
Temperature measuring transducer
MACX MCR-EX-TS-I-OLP-C - 1012248
Ex i, Output loop-powered temperature transducer for transmitting up to 2 sensor signals from RTD and TC sensors, as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Order configuration, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Screw connection
Signal conditioner
MACX MCR-UI-UI-SP - 2811572
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL.
Solenoid driver
MACX MCR-EX-SL-SD-21-25-LFD-SP - 2905674
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 21.1 V, current limitation at 25.1 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; Push-in connection.
Temperature measuring transducer
MACX MCR-EX-T-UI-UP-C - 2811763
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Dummy
MACX MCR-EX-DUMMY-ISOLATOR - 2904970
Dummy module with no function for connecting unused intrinsically safe signal cables, with plug-in screw connection terminal blocks.
Dummy
MACX MCR-EX-DUMMY-ISOLATOR-SP - 2905846
Dummy module with no function for connecting unused intrinsically safe signal cables, with plug-in push-in connection terminal blocks.
Output signal conditioner
MACX MCR-IDS-2I-2I - 2908065
2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection.
Solenoid driver
MACX MCR-EX-SL-SD-21-25-LFD - 2905669
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 21.1 V, current limitation at 25.1 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.
Isolation amplifier
MACX MCR-EX-SL-NAM-NAM-SP - 2924883
Ex i NAMUR signal conditioner for operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive in accordance with EN 60947-5-6), line fault transparency, up to SIL 2 in accordance with IEC 61508, Push-in connection
Solenoid driver
MACX MCR-EX-SL-SD-23-48-LFD-SP - 2924870
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 in accordance with IEC 61508, Push-in connection
Temperature measuring transducer
MACX MCR-EX-T-UIREL-UP - 2865751
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Power/input isolating amplifier
MACX MCR-SL-RPSSI-I-SP - 2924207
Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 in accordance with IEC 61508.
Solenoid driver
MACX MCR-EX-SL-SD-24-48-LFD - 2906155
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.
Power/input isolating amplifier
MACX MCR-EX-SL-RPSSI-I-UP-SP - 2924029
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. SIL 2 (1oo1) / SIL 3 (1oo2), wide-range supply.
Solenoid driver
MACX MCR-EX-SL-SD-24-48-LFD-SP - 2906156
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508, Push-in connection.
Temperature measuring transducer
MACX MCR-T-UIREL-UP-C - 2811514
Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
Output signal conditioner
MACX MCR-IDS-I-I - 2908063
Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.