Bộ cách ly tín hiệu Phoenix Contact MACX MCR-SL-RPSS-2I-2I | 2904089

Bộ cách ly tín hiệu Phoenix Contact MACX MCR-SL-RPSS-2I-2I | 2904089

255
Nhà sản xuất: Phoenix Contact;    Xuất xứ: Germany
Giá sỉ:Giá tốt nhất xem...0909186879 dienelectrics@gmail.com
Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Bộ cách ly tín hiệu Phoenix Contact MACX MCR-SL-RPSS-2I-2I | 2904089

 

Thông số kỹ thuật

Đặc tính sản phẩm

Product type Repeater power supplies
Application Analog IN
No. of channels 2
Type Signal conditioners with SIL and PL Functional Safety
Insulation characteristics
Overvoltage category II
Pollution degree 2
 

Thông số về điện

No. of channels 2
Signal transmission behavior In = Out
Step response (10-90%) < 1.3 ms (for 4 mA ... 20 mA step)
Maximum temperature coefficient < 0.01 %/K
Maximum transmission error < 0.1 % (of final value)
Transmission error, typical < 0.05 % (of final value)
Electrical isolation Input/output, power supply
Rated insulation voltage 300 Vrms
Test voltage 2.5 kV AC (50 Hz, 60 s)
Insulation Safe isolation in accordance with IEC/EN 61010-1
Electrical isolation Output 1/output 2/ power supply
Test voltage 1.5 kV AC (50 Hz, 60 s)
Supply
Nominal supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption < 100 mA (24 V / 20 mA)
Power dissipation < 1.4 W (at 24 V DC / 20 mA)
 

Thông số đầu vào

Signal: Current
Number of inputs 2
Current input signal 4 mA ... 20 mA
Transmitter supply voltage > 16 V (20 mA)
Underload/overload signal range 0 mA ... 24 mA
 

Thông số đầu ra

Signal
Output description Current output
Number of outputs 2
Current output signal 4 mA ... 20 mA (active)
Load/output load current output ≤ 450 Ω (20 mA)
≤ 375 Ω (24 mA)
Output behavior in the event of an error < 3.6 mA (In the event of cable break at the input (as per NE 43))
> 22.5 mA (In the event of cable short circuit at the input (as per NE 43))
Underload/overload signal range 0 mA ... 24 mA
 

Thông số kết nối

Connection method Screw connection
Stripping length 7 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
 

Thông số giao diện

Data communication (bypass)
HART function Yes
Protocols supported HART-transparent
 

Thông số đèn LED tín hiệu

Status display Green LED (supply voltage)
 

Thông số kích thước

Width 12.5 mm
Height 112.5 mm
Depth 113.7 mm
Depth NS 35/7,5 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)
 

Thông số đặc tính cơ học

Flammability rating according to UL 94 V0 (Housing)
Housing material PA 6.6-FR
 

Thông số môi trường hoạt động và Cấp bảo vệ

Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -40 °C ... 70 °C (Any mounting position)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
 

Approval data

CE
Certificate CE-compliant
Note and EN 61326
ATEX
Identification  II 3 G Ex nA IIC T4 Gc X
UKCA Ex (UKEX)
Identification  II 3 G Ex nA IIC T4 Gc
Certificate PxCIF21UKEX2904089X
UL, USA / Canada
Identification UL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Groups IIC, IIB, IIA T4
UL, USA / Canada
Identification UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
Certificate DNV GL TAA000020C
Safety Integrity Level (SIL, IEC 61508)
Identification 2
Safety Integrity Level (SIL, IEC 61508)
Identification 3
Certificate BVS PB 04-13
Performance Level (ISO 13849)
Identification d
Systematic Capability
Identification 3
DNV GL data
Temperature B
Humidity B
Vibration A
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board
 

EMC data

Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.
 

Lắp đặt

Mounting type DIN rail mounting
 

Thông số thương mại

Item number 2904089
Packing unit 1 pc
Minimum order quantity 1 pc
Product Key CK1111
Catalog Page Page 123 (C-5-2019)
GTIN 4046356772792
Weight per Piece (including packing) 243 g
Weight per Piece (excluding packing) 140 g
Customs tariff number 85437090
Country of origin DE


- Tài liệu kỹ thuật Phoenix Contact MACX MCR-SL-RPSS-2I-2I | 2904089 ở đây.


Tham khảo thêm các model khác cùng loại:
Temperature measuring transducer

MACX MCR-T-UI-UP - 2811394

Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Power/input isolating amplifier

MACX MCR-EX-SL-RPSSI-I - 2865340

Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. 3-way electrical isolation, SIL 2 in accordance with IEC 61508, with screw connection

Isolation amplifier

MACX MCR-EX-SL-2NAM-RO-SP - 2924087

Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Power/input isolating amplifier

MACX MCR-EX-SL-RPSSI-I-SP - 2924016

Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. 3-way electrical isolation, SIL 2 in accordance with IEC 61508, with Push-in connection

Signal conditioner

MACX MCR-UI-UI-NC - 2811446

Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.

Programming adapter

IFS-USB-PROG-ADAPTER - 2811271

Programming adapter with USB interface, for programming with software. The USB driver is included in the software solutions for the products to be programmed, such as measuring transducers or motor managers.

Power and error message module

MACX MCR-PTB-SP - 2924184

Power and fault signaling module with Push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector

Isolation amplifier

MACX MCR-EX-SL-NAM-2RO-SP - 2924061

Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Temperature measuring transducer

MACX MCR-T-UIREL-UP - 2811378

Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Loop-powered isolators

MACX MCR-SL-I-I-ILP - 2905278

1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.

Isolation amplifier

MACX MCR-EX-SL-2NAM-RO - 2865476

Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Power/input isolating amplifier

MACX MCR-SL-RPSSI-I - 2865955

Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 in accordance with IEC 61508.

Signal isolator

MACX MCR-EX-SL-RPSS-2I-2I - 2865382

Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, screw connection, up to SIL 3, PL.

Isolation amplifier

MACX MCR-EX-SL-NAM-2T-SP - 2924074

Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Repeater power supply

MACX MCR-SL-RPSSI-I-UP - 2865968

Repeater power supply for supplying 2- and 3-conductor transmitters with Hart transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), screw connection

Signal conditioner

MACX MCR-UI-UI-UP-NC - 2811297

Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), screw connection, SIL.

Repeater power supply

MACX MCR-SL-RPSSI-2I - 2924825

Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.

Temperature measuring transducer

MACX MCR-EX-1TS-I-OLP - 1145365

Ex i, Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Screw connection

Isolation amplifier

MACX MCR-EX-SL-NAM-R - 2865434

Ex i NAMUR signal conditioner. For operating proximity sensors and switches in a potentially explosive area. The signals are transmitted by a relay output (changeover contact) to a safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Isolation amplifier

MACX MCR-SL-NAM-2RO - 2865010

NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, screw connection.

Isolation amplifier

MACX MCR-EX-SL-NAM-2RO - 2865450

Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Output signal conditioner

MACX MCR-EX-IDS-I-I - 2908060

Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.

Isolation amplifier

MACX MCR-EX-SL-2NAM-T - 2865489

Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Repeater power supply

MACX MCR-SL-RPSSI-I-UP-SP - 2924210

Repeater power supply for supplying 2- and 3-conductor transmitters with HART transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), Push-in connection

Temperature measuring transducer

MACX MCR-EX-RTD-I - 1050222

Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, SIL, screw connection, standard configuration.

Temperature measuring transducer

MACX MCR-EX-RTD-I-SP - 1050252

Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, standard configuration.

Temperature measuring transducer

MACX MCR-RTD-I - 1050192

Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.

Temperature measuring transducer

MACX MCR-1TS-I-OLP - 1145192

Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Screw connection

Signal isolator

MACX MCR-EX-SL-RPSS-2I-2I-SP - 2924676

Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL.

Temperature measuring transducer

MACX MCR-T-UI-UP-C - 2811873

Freely programmable temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Isolation amplifier

MACX MCR-SL-2NAM-RO - 2865049

NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.

Isolation amplifier

MACX MCR-EX-SL-2NAM-R-UP - 2865984

2-channel Ex i NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Fault detection (LFD), 3-way isolation, SIL 2.

Loop-powered isolators

MACX MCR-SL-2I-2I-ILP - 2905280

2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.

Isolation amplifier

MACX MCR-SL-2NAM-RO-SP - 2924294

NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.

Isolation amplifier

MACX MCR-SL-2NAM-R-UP-SP - 2924304

2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.

Limit value switches

MACX MCR-SL-UI-REL - 2906169

Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.

Output signal conditioner

MACX MCR-EX-IDS-I-I-SP - 2908062

Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.

Signal conditioner

MACX MCR-UI-UI - 2811284

Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL.

Temperature measuring transducer

MACX MCR-EX-T-UI-UP-SP - 2924689

Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Temperature measuring transducer

MACX MCR-T-UIREL-UP-SP - 2811828

Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

HART transfer board

MACX MCR-S-MUX-TB - 2308124

The HART transfer board is used to operate the MACX-MCR-S-MUX HART multiplexer. The signals from the HART-compatible signal converters are applied to the terminal strip of the transfer board where they are then transmitted to the multiplexer via an FLK.

Signal isolator

MACX MCR-SL-RPSS-2I-2I-SP - 2904090

2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, Push-in connection, SIL, PL.

Isolation amplifier

MACX MCR-SL-NAM-R - 2865997

NAMUR signal conditioners for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with screw connection.

Repeater power supply

MACX MCR-EX-SL-RPSSI-2I-SP - 2924236

Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4 mA ... 20 mA electrical isolation signals from the Ex area to two loads in the safe area. 4-way electrical isolation, Push-in connection, SIL, PL.

Signal conditioner

MACX MCR-UI-UI-UP-SP-NC - 2811569

Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), spring-cage connection, SIL.

Solenoid driver

MACX MCR-EX-SL-SD-21-40-LP-SP - 2924139

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.

Signal conditioner

MACX MCR-UI-UI-UP - 2811459

Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, screw connection, SIL.

Isolation amplifier

MACX MCR-SL-2NAM-R-UP - 2865052

2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, screw connection, SIL 2.

Repeater power supply

MACX MCR-EX-SL-RPSSI-2I - 2865366

Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4…20 mA electrically isolated signals from the Ex area to two loads in the safe area. 4-way electrical isolation, screw connection, SIL, PL.

Isolation amplifier

MACX MCR-SL-NAM-2RO-SP - 2924265

NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection.

Solenoid driver

MACX MCR-EX-SL-SD-21-60-LP-SP - 2924100

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Push-in connection.

Isolation amplifier

MACX MCR-EX-SL-NAM-2T - 2865463

Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Temperature measuring transducer

MACX MCR-RTD-I-SP - 1050201

Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.

Signal conditioner

MACX MCR-UI-UI-SP-NC - 2811556

Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configuration (IN 0 ... 10 V/OUT 0 ... 20 mA), spring-cage connection, SIL.

Limit value switches

MACX MCR-SL-UI-REL-SP - 2906170

Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.

Isolation amplifier

MACX MCR-SL-NAM-2T - 2865023

NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.

Temperature measuring transducer

MACX MCR-T-UI-UP-SP - 2811860

Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Temperature measuring transducer

MACX MCR-EX-T-UI-UP - 2865654

Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Signal isolator

MACX MCR-SL-RPSS-2I-2I - 2904089

2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digital HART transparency, screw connection, SIL, PL.

Solenoid driver

MACX MCR-EX-SL-SD-23-48-LFD - 2924867

Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 in accordance with IEC 61508, screw connection

Power and error message module

MACX MCR-PTB - 2865625

Power and fault signaling module with screw connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector

Isolation amplifier

MACX MCR-EX-SL-NAM-R-SP - 2924045

Ex i NAMUR signal conditioner. For operating proximity sensors and switches in a potentially explosive area. The signals are transmitted by a relay output (changeover contact) to a safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Isolation amplifier

MACX MCR-SL-2NAM-T - 2865036

NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.

Isolation amplifier

MACX MCR-EX-SL-2NAM-T-SP - 2924090

Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.

Loop-powered isolators

MACX MCR-SL-I-I-HV-ILP-SP - 2907705

1-channel input loop-powered 2-way isolator with increased isolating voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.

Loop-powered isolators

MACX MCR-SL-2I-2I-HV-ILP-SP - 2907707

Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.

Repeater power supply

MACX MCR-SL-RPSSI-2I-SP - 2924838

Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 mA … 20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL.

Isolation amplifier

MACX MCR-EX-SL-2NAM-R-UP-SP - 2924249

2-channel Ex i NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Fault detection (LFD), 3-way isolation, SIL 2.

Solenoid driver

MACX MCR-EX-SL-SD-24-48-LP-SP - 2924126

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.

Power/input isolating amplifier

MACX MCR-EX-SL-RPSSI-I-UP - 2865793

Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. SIL 2 (1oo1) / SIL 3 (1oo2), wide-range supply.

Solenoid driver

MACX MCR-EX-SL-SD-24-48-LP - 2865609

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.

Output signal conditioner

MACX MCR-EX-IDS-2I-2I - 2865421

2-channel Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection.

Loop-powered isolators

MACX MCR-SL-I-I-HV-ILP - 2907704

1-channel input loop-powered 2-way isolator with increased isolating voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology.

Output signal conditioner

MACX MCR-IDS-I-I-SP - 2908064

Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.

DIN rail bus connectors

ME 6,2 TBUS-PR-ADAPTER - 1136500

Power rail adapter (ME 6,2 TBUS-PR-ADAPTER), 2-pos., enables MINI and MACX Analog modules to be adapted for supply via universal power rail UPR-03 and UPR-05.

Isolation amplifier

MACX MCR-SL-NAM-R-SP - 2924252

NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via relay output (changeover contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, with Push-in connection.

Loop-powered isolators

MACX MCR-SL-I-I-ILP-SP - 2905279

1-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.

HART multiplexer

MACX MCR-S-MUX - 2865599

HART Multiplexer for online configuration and diagnostics of HART-compatible field devices, as well as for continuous documentation of process variables and states with a PC or management system for mounting on NS 35/7.5 or NS 32

Solenoid driver

MACX MCR-EX-SL-SD-21-25-LP-SP - 2924113

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.

Temperature measuring transducer

MACX MCR-EX-1TS-I-OLP-SP - 1145207

Ex i, Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Push-in connection

Solenoid driver

MACX MCR-EX-SL-SD-21-60-LP - 2865515

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Screw connection.

Solenoid driver

MACX MCR-EX-SL-SD-21-25-LP - 2865492

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.

Temperature measuring transducer

MACX MCR-EX-TC-I-C - 1052458

Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Order configuration, freely programmable. 3-way isolation, SIL.

Temperature measuring transducer

MACX MCR-EX-T-UIREL-UP-SP-C - 2924809

Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Temperature measuring transducer

MACX MCR-RTD-I-C - 1052472

Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, order configuration.

Temperature measuring transducer

MACX MCR-EX-TC-I - 1050233

Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, screw connection, SIL.

Isolation amplifier

MACX MCR-EX-SL-NAM-NAM - 2866006

Ex i NAMUR signal conditioner for operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive in accordance with EN 60947-5-6), line fault transparency, up to SIL 2 in accordance with IEC 61508, screw connection

Loop-powered isolators

MACX MCR-SL-2I-2I-HV-ILP - 2907706

Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Screw connection technology

Temperature measuring transducer

MACX MCR-RTD-I-SP-C - 1052464

Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, order configuration.

Temperature measuring transducer

MACX MCR-T-UI-UP-SP-C - 2811970

Freely programmable temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Signal conditioner

MACX MCR-UI-UI-UP-SP - 2811585

Configurable 3-way isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL.

Temperature measuring transducer

MACX MCR-EX-RTD-I-C - 1052463

Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, SIL, screw connection, order configuration.

Output signal conditioner

MACX MCR-EX-IDS-2I-2I-SP - 2904931

2-channel Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.

Temperature measuring transducer

MACX MCR-1TS-I-OLP-SP - 1145196

Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Push-in connection

Temperature measuring transducer

MACX MCR-EX-T-UIREL-UP-C - 2865722

Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Loop-powered isolators

MACX MCR-SL-2I-2I-ILP-SP - 2905281

2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.

Temperature measuring transducer

MACX MCR-T-UIREL-UP-SP-C - 2811831

Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Solenoid driver

MACX MCR-EX-SL-SD-21-40-LP - 2865764

Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.

Temperature measuring transducer

MACX MCR-EX-RTD-I-SP-C - 1052652

Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, order configuration.

Repeater power supply

MACX MCR-EX-SL-RPSSI-2I-1S - 2908855

Ex i measuring transducer repeater power supply and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active electrically isolated signals from the Ex area to two loads. SIL 2 in accordance with IEC 61508, screw connection.

Isolation amplifier

MACX MCR-SL-2NAM-T-SP - 2924281

NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.

Limit value switches

MACX MCR-EX-SL-UI-REL-SP - 2906165

Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.

Temperature measuring transducer

MACX MCR-TC-I-C - 1052459

Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Order configuration, freely programmable, 3-way electrical isolation, screw connection, SIL.

Temperature measuring transducer

MACX MCR-EX-T-UI-UP-SP-C - 2924692

Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Repeater power supply

MACX MCR-EX-SL-RPSSI-2I-1S-SP - 2908856

Ex i measuring transducer repeater power supply and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active electrically isolated signals from the Ex area to two loads. SIL 2 in accordance with IEC 61508, Push-in connection.

Isolation amplifier

MACX MCR-SL-NAM-2T-SP - 2924278

NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.

Limit value switches

MACX MCR-EX-SL-UI-REL - 2906164

Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.

Temperature measuring transducer

MACX MCR-EX-T-UIREL-UP-SP - 2924799

Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

Output signal conditioner

MACX MCR-IDS-2I-2I-SP - 2908066

2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.

Temperature measuring transducer

MACX MCR-TC-I - 1050228

Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Freely programmable, 3-way electrical isolation, screw connection, SIL.

Temperature measuring transducer

MACX MCR-EX-TS-I-OLP-C - 1012248

Ex i, Output loop-powered temperature transducer for transmitting up to 2 sensor signals from RTD and TC sensors, as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Order configuration, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Screw connection

Signal conditioner

MACX MCR-UI-UI-SP - 2811572

Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration, spring-cage connection, SIL.

Solenoid driver

MACX MCR-EX-SL-SD-21-25-LFD-SP - 2905674

Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 21.1 V, current limitation at 25.1 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; Push-in connection.

Temperature measuring transducer

MACX MCR-EX-T-UI-UP-C - 2811763

Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Dummy

MACX MCR-EX-DUMMY-ISOLATOR - 2904970

Dummy module with no function for connecting unused intrinsically safe signal cables, with plug-in screw connection terminal blocks.

Dummy

MACX MCR-EX-DUMMY-ISOLATOR-SP - 2905846

Dummy module with no function for connecting unused intrinsically safe signal cables, with plug-in push-in connection terminal blocks.

Output signal conditioner

MACX MCR-IDS-2I-2I - 2908065

2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection.

Solenoid driver

MACX MCR-EX-SL-SD-21-25-LFD - 2905669

Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 21.1 V, current limitation at 25.1 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.

Isolation amplifier

MACX MCR-EX-SL-NAM-NAM-SP - 2924883

Ex i NAMUR signal conditioner for operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive in accordance with EN 60947-5-6), line fault transparency, up to SIL 2 in accordance with IEC 61508, Push-in connection

Solenoid driver

MACX MCR-EX-SL-SD-23-48-LFD-SP - 2924870

Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 in accordance with IEC 61508, Push-in connection

Temperature measuring transducer

MACX MCR-EX-T-UIREL-UP - 2865751

Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Power/input isolating amplifier

MACX MCR-SL-RPSSI-I-SP - 2924207

Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 in accordance with IEC 61508.

Solenoid driver

MACX MCR-EX-SL-SD-24-48-LFD - 2906155

Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.

Power/input isolating amplifier

MACX MCR-EX-SL-RPSSI-I-UP-SP - 2924029

Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. SIL 2 (1oo1) / SIL 3 (1oo2), wide-range supply.

Solenoid driver

MACX MCR-EX-SL-SD-24-48-LFD-SP - 2906156

Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508, Push-in connection.

Temperature measuring transducer

MACX MCR-T-UIREL-UP-C - 2811514

Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.

Output signal conditioner

MACX MCR-IDS-I-I - 2908063

Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.
SẢN PHẨM XEM NHIỀU
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại