Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450 là Bộ khuếch đại chuyển mạch cách ly Ex i NAMUR, 2 đầu ra rơle (N/O), cách ly 3 chiều, SIL 2.
- Tài liệu kỹ thuật của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450 ở đây.
Product properties của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Product type |
Isolating switch amplifier |
Product family |
MACX Analog |
Application |
Digital IN |
No. of channels |
1 |
Type |
Ex i signal conditioners with SIL functional safety |
Configuration |
DIP switches |
System properties của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Functionality |
Configuration |
DIP switches |
Electrical properties của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Electrical isolation |
3-way isolation |
Electrical isolation between input and output |
yes |
Electrical isolation Input/output IEC/EN 60079-11 |
Standards/regulations |
IEC/EN 60079-11 |
Rated insulation voltage |
375 VPP |
Overvoltage category |
III |
Pollution degree |
2 |
Electrical isolation Input/supply, DIN rail connector IEC/EN 60079-11 |
Standards/regulations |
IEC/EN 60079-11 |
Rated insulation voltage |
375 VPP |
Overvoltage category |
II |
Pollution degree |
2 |
Electrical isolation Input/supply, DIN rail connector IEC/EN 61010-1 |
Standards/regulations |
IEC/EN 61010-1 |
Rated insulation voltage |
300 Vrms |
Overvoltage category |
II |
Pollution degree |
2 |
Insulation |
Safe isolation |
Electrical isolation Output 1/output 2/input, power supply, DIN rail connector IEC/EN 61010-1 |
Standards/regulations |
IEC/EN 61010-1 |
Rated insulation voltage |
300 Vrms |
Overvoltage category |
III |
Pollution degree |
2 |
Insulation |
Safe isolation |
Electrical isolation Output 1/output 2/input/power supply, DIN rail connector |
Test voltage |
2.5 kV AC (50 Hz, 60 s) |
Overvoltage category |
III |
Pollution degree |
2 |
Supply |
Nominal supply voltage |
24 V DC -20 % ... +25 % |
Supply voltage range |
19.2 V DC ... 30 V DC |
Max. current consumption |
30 mA (24 V DC) |
Power dissipation |
< 1 W |
Power consumption |
< 1 W |
Input data của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Signal: NAMUR |
Description of the input |
Intrinsically safe |
Number of inputs |
1 |
Available input sources |
NAMUR proximity sensors (IEC/EN 60947-5-6) |
Floating switch contacts |
Switch contacts with resistance circuit |
Switching threshold "0" signal current |
< 1.2 mA (blocking) |
Switching threshold "1" signal, current |
> 2.1 mA (conductive) |
Short-circuit current |
8 mA |
Switching hysteresis |
< 0.2 mA |
Line fault detection |
< 0.05 mA ... 0.35 mA (Line break) |
< 100 Ω ... 360 Ω (Short circuit) |
Activated /deactivated via DIP switch |
Non-load voltage |
8 V DC |
Output data của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Switching: Relay |
Contact switching type |
2 N/O contacts |
Contact material |
AgSnO2, hard gold-plated |
Maximum switching voltage |
250 V AC (2 A) |
120 V DC (0.2 A) |
30 V DC (2 A) |
Maximum switching capacity |
500 VA |
Recommended minimum load |
5 V / 10 mA |
Switching frequency |
≤ 20 Hz (without load) |
Signal |
Number of outputs |
2 |
Connection data của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Connection method |
Screw connection |
Stripping length |
7 mm |
Screw thread |
M3 |
Conductor cross section rigid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Tightening torque |
0.5 Nm ... 0.6 Nm |
Test socket |
Max. diameter |
2 mm |
Ex data của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Ex installation (EPL) |
Gc |
Div. 2 |
Ex i circuits (EPL) |
Ga |
Da |
Ma |
Div. 1 |
Safety data |
Max. internal inductance Li |
negligible |
Max. internal capacitance Ci |
11 nF |
Max. output voltage Uo |
9.6 V |
Max. output current Io |
10 mA |
Max. output power Po |
25 mW |
Safety-related maximum voltage Um |
253 V AC |
125 V DC |
IIA/I (simple circuit): Max. external inductivity Lo / Max. external capacitance Co |
1000 mH / 210 µF |
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co |
1000 mH / 26 µF |
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co |
300 mH / 3.6 µF |
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co |
100 mH / 500 nF, 50 mH / 570 nF, 5 mH / 590 nF, 1 mH / 590 nF, 10 µH / 590 nF |
I/IIB/IIA/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co |
100 mH / 1 µF, 5 mH / 1 µF, 1 mH / 1 µF, 10 µH / 1 µF |
Signaling của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Status display |
Green LED (supply voltage) |
LED yellow (switching state) |
Red LED (line errors) |
Dimensions của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Dimensional drawing |
|
Width |
12.5 mm |
Height |
112.5 mm |
Depth |
113.7 mm |
Depth NS 35/7,5 |
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Color |
gray (RAL 7042) |
Flammability rating according to UL 94 |
V0 (Housing) |
Housing material |
PA 6.6-FR |
Environmental and real-life conditions của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Ambient conditions |
Degree of protection |
IP20 (not assessed by UL) |
Ambient temperature (operation) |
-40 °C ... 60 °C (Any mounting position) |
-40 °C ... 70 °C (Derating) |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Permissible humidity (operation) |
10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) |
5 % ... 95 % (non-condensing) |
Altitude range (≤ 2000 m) |
Altitude |
≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
Ambient temperature (operation) |
-40 °C ... 60 °C |
-40 °C ... 70 °C (Derating) |
Rated insulation voltage |
253 V AC (Power supply, input / output) |
125 V DC (Power supply, input / output) |
Altitude range (≤ 3000 m) |
Height range |
> 2000 m ... 3000 m |
Ambient temperature (operation) |
-40 °C ... 54 °C |
-40 °C ... 63 °C (Derating) |
Rated insulation voltage |
190 V AC (Power supply, input / output) |
110 V DC (Power supply, input / output) |
Altitude range (≤ 4000 m) |
Height range |
> 3000 m ... 4000 m |
Ambient temperature (operation) |
-40 °C ... 48 °C |
-40 °C ... 56 °C (Derating) |
Rated insulation voltage |
60 V AC/DC (Power supply, input / output) |
Altitude range (≤ 5000 m) |
Height range |
> 4000 m ... 5000 m |
Ambient temperature (operation) |
-40 °C ... 42 °C |
-40 °C ... 49 °C (Derating) |
Rated insulation voltage |
60 V AC/DC (Power supply, input / output) |
Approvals của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
CE |
Certificate |
CE-compliant |
Note |
and EN 61326 |
ATEX |
Identification |
II (1) G [Ex ia Ga] IIC |
II (1) D [Ex ia Da] IIIC |
II 3 (1) G Ex ec [ia Ga] nC IIC T4 Gc |
I (M1) [Ex ia Ma] I |
Certificate |
IBExU 07 ATEX 1069 X |
IECEx |
Identification |
[Ex ia Ga] IIC |
[Ex ia Da] IIIC |
Ex ec [ia Ga] nC IIC T4 Gc |
[Ex ia Ma] I |
Certificate |
IECEx IBE 08.0001X |
CCC / China-Ex |
Identification |
[Ex ia Ga] IIC |
[Ex ia Da] IIIC |
Ex ec nC [ia Ga] IIC T4 Gc |
Certificate |
2022122316115975 |
UL, USA/Canada |
Identification |
UL 61010 Listed |
Class I, Div. 2, Groups A, B, C, D T4 |
Class I, Div. 2, Groups IIC, IIB, IIA T4 |
Associated apparatus for use in Class I, Division 1, Groups A,B,C,D |
Associated apparatus for use in Class II, Div.1 Groups E,F,G |
Associated apparatus for use in Class III, Division 1 |
Associated apparatus for use in Class I, Zone 0,1,2, Groups IIC,IIB,IIA |
Certificate |
, C.D.-No 83104549 |
UL, USA/Canada |
Identification |
Class I Div 2; IS for Class I, II, III Div 1 |
UL 61010 Listed |
Certificate |
, C.D.-No 83104549 |
KC-s |
Identification |
[Ex ia] IIC/IIB |
Certificate |
17-KA4BO-0409X |
Shipbuilding approval |
Certificate |
DNV GL TAA00000AG |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
2 |
Certificate |
IN-AT-AS-MRL-24-00163 |
Systematic Capability |
Identification |
3 |
INMETRO |
Identification |
[Ex ia Ga] IIC |
[Ex ia Da] IIIC |
Ex ec nC [ia Ga] IIC T4 Gc |
[Ex ia Ma] I |
Certificate |
DNV 18.0114 X |
Shipbuilding data |
Temperature |
B |
Humidity |
B |
Vibration |
A |
EMC |
B |
Enclosure |
Required protection according to the Rules shall be provided upon installation on board |
EMC data của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Electromagnetic compatibility |
Conformance with EMC directive |
Noise immunity |
EN 61000-6-2 |
EN 61326 |
Noise emission |
Standards/regulations |
EN 61000-6-4 |
Standards and regulations của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Electrical isolation |
3-way isolation |
GB Standard |
Standards/regulations |
GB/T 3836.1 |
GB/T 3836.3 |
GB/T 3836.4 |
GB/T 3836.8 |
Mounting của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Mounting type |
DIN rail mounting |
Commercial data của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
Item number |
2865450 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Sales key |
DK1213 |
Product key |
DK1213 |
Catalog page |
Page 155 (C-5-2019) |
GTIN |
4046356160476 |
Weight per piece (including packing) |
183.1 g |
Weight per piece (excluding packing) |
140 g |
Customs tariff number |
85365019 |
Country of origin |
DE |
Classifications của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
ECLASS
ECLASS-11.0 |
27210121 |
ECLASS-12.0 |
27210121 |
ECLASS-13.0 |
27210121 |
ECLASS-14.0 ASSET |
27250101 |
ETIM
UNSPSC
Approvals của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
UL Listed
Approval ID: E330267
cUL Listed
Approval ID: E330267
Functional Safety
Approval ID: 07-06-39 R005 V2R2
DNV
Approval ID: TAA00000AG
EAC Ex
Approval ID: TR TS_S_103.01.00078
IECEx
Approval ID: IECEx IBE 08.0001X
cUL Listed
Approval ID: E199827
UL Listed
Approval ID: E199827
ATEX
Approval ID: IBExU07ATEX1069
INMETRO
Approval ID: DNV 18.0114 X
KC-s
Approval ID: 17-KA4BO-0409X
CCC
Approval ID: 2022122316115975
Environmental product compliance của Bộ khuếch đại chuyển mạch cách ly Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450
EU RoHS |
Fulfills EU RoHS substance requirements |
Yes |
Exemption |
7(a), 7(c)-I |
China RoHS |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
EU REACH SVHC |
REACH candidate substance (CAS No.) |
Lead (CAS: 7439-92-1) |
2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol (CAS: 79-94-7) |
SCIP |
b7380afc-6794-4c77-8a04-f3e9464b8db7 |
Tham khảo thêm các model khác cùng loại với Bộ khuếch đại Phoenix Contact MACX MCR-EX-SL-NAM-2RO - 2865450:
MACX MCR-EX-SL-NAM-R-SP - Isolation switch amplifier
2924045
Ex i NAMUR isolation amplifier. For operating proximity sensors and switches in a potentially explosive area. The signals are transmitted by a relay output (changeover contact) to a safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-RPSSI-I - Power/input isolating amplifier
2865340
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. 3-way electrical isolation, SIL 2 in accordance with IEC 61508, with screw connection
MACX MCR-EX-SL-2NAM-RO - Isolation switch amplifier
2865476
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-2NAM-RO-SP - Isolation switch amplifier
2924087
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-RPSSI-I-SP - Power/input isolating amplifier
2924016
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. 3-way electrical isolation, SIL 2 in accordance with IEC 61508, with Push-in connection
MACX MCR-EX-SL-2NAM-R-UP-SP - Isolation switch amplifier
2924249
2-channel Ex i NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-RTD-I-SP - Temperature measuring transducer
1050252
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, standard configuration.
MACX MCR-EX-IDS-I-I-SP - Output signal conditioner
2908062
Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
MACX MCR-EX-SL-RPSSI-I-UP - Power/input isolating amplifier
2865793
Ex i repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals from the Ex area to a load (active or passive) in the safe area. SIL 2 (1oo1) / SIL 3 (1oo2), wide-range supply.
MACX MCR-EX-SL-2NAM-T-SP - Isolation switch amplifier
2924090
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-TC-I - Temperature measuring transducer
1050233
Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, screw connection, SIL.
MACX MCR-EX-RTD-I - Temperature measuring transducer
1050222
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, SIL, screw connection, standard configuration.
MACX MCR-EX-SL-NAM-2RO - Isolation switch amplifier
2865450
Ex i NAMUR isolating amplifier for operating proximity sensors and switches in the Ex area. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-SD-21-60-LP - Solenoid driver
2865515
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Screw connection.
MACX MCR-EX-SL-RPSS-2I-2I - Repeater power supply
2865382
Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, screw connection, up to SIL 3, PL.
MACX MCR-EX-SL-2NAM-T - Isolation switch amplifier
2865489
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-RPSS-2I-2I-SP - Repeater power supply
2924676
Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL.
2908060
Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.
MACX MCR-EX-SL-SD-21-40-LP-SP - Solenoid driver
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
MACX MCR-EX-SL-SD-24-48-LP - Solenoid driver
2865609
MACX MCR-EX-T-UIREL-UP - Temperature measuring transducer
2865751
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
MACX MCR-EX-IDS-2I-2I-SP - Output signal conditioner
2904931
2-channel Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
2924236
Ex i-Measuring transducer repeater power supply and input signal conditioner transmits supplied or active 0 mA/4 mA ... 20 mA electrically isolated signals from the Ex area to two loads in the safe area. number of channels: 1, HART-transparent, Standard configuration, 3-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Performance Level (ISO 13849): d / KAT 2, Systematic Capability: 3, Push-in connection
MACX MCR-EX-AP-RPSS-I-I-SP - Power/input isolating amplifier
Ex i-Feed and input signal conditioner feeds 2-, 3- and 4-conductor measuring transducer and transmits 1:1 passive or active 0 mA / 4 mA ... 20 mA Ex i input signals as active non Ex i output signal. number of channels: 1, HART-transparent, Standard configuration, 3-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MACX MCR-EX-SL-RPSSI-2I - Repeater power supply
2865366
MINI MCR-EX-RPSS-I-I - Repeater power supply
2908803
Ex i-Repeater power supply and input signal conditioner transmits supplied or active 0 mA/4 mA ... 20 mA signals from the Ex area to a load in the safe area.. HART-transparent, no-load voltage: 15 V DC, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
2865434
Ex i NAMUR isolation amplifier. For operating proximity sensors and switches in a potentially explosive area. The signals are transmitted by a relay output (changeover contact) to a safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-NAM-2T-SP - Isolation switch amplifier
2924074
Ex i NAMUR isolating amplifier for operating proximity sensors and switches in the Ex area. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-SD-21-25-LP-SP - Solenoid driver
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
MINI MCR-EX-NAM-RO - Isolation switch amplifier
1157862
MACX MCR-EX-SL-2NAM-R-UP - Isolation switch amplifier
2865984
2-channel Ex i NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Fault detection (LFD), 3-way isolation, SIL 2.
2865764
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
MACX MCR-EX-SL-NAM-2RO-SP - Isolation switch amplifier
Ex i NAMUR isolating amplifier for operating proximity sensors and switches in the Ex area. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-UI-REL-SP - Limit value switch
2906165
MINI MCR-EX-NAM-2T-PT - Isolation switch amplifier
1157854
Ex i-NAMUR signal conditioner for operating proximity sensors and switches in the Ex area. The signals are transmitted to the safe area via 2 transistor outputs (passive). Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
2908856
Ex i-Measuring transducer repeater power supply and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active electrically isolated signals from the Ex area to two loads. number of channels: 1, HART-transparent, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 2, Performance Level (ISO 13849): d / KAT 2, Systematic Capability: 3, Push-in connection
MACX MCR-EX-SL-UI-REL - Limit value switch
Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.
MINI MCR-EX-NAM-T-PT - Isolation switch amplifier
2908808
MINI MCR-EX-IDS-I-I-PT - Output signal conditioner
2908806
Ex i-Output signal conditioner for isolating and transmitting 0 mA / 4 mA ... 20 mA signals from the controller to an intrinsically safe load in the Ex area. HART-transparent, no-load voltage: 27 V DC, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
2924799
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
MACX MCR-EX-SL-NAM-2T - Isolation switch amplifier
Ex i NAMUR isolating amplifier for operating proximity sensors and switches in the Ex area. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
MACX MCR-EX-SL-SD-21-25-LFD - Solenoid driver
2905669
MACX MCR-EX-T-UI-UP-SP - Temperature measuring transducer
2924689
Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
2865421
2-channel Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection.
MACX MCR-EX-SL-SD-24-48-LFD - Solenoid driver
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.
MACX MCR-EX-SL-RPSSI-I-UP-SP - Power/input isolating amplifier
2924029
MACX MCR-EX-T-UI-UP - Temperature measuring transducer
2865654
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection, SIL, PL.
2924867
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 in accordance with IEC 61508, screw connection
MINI MCR-EX-RPSS-I-I-PT - Repeater power supply
Ex i-Repeater power supply and input signal conditioner transmits supplied or active 0 mA/4 mA ... 20 mA signals from the Ex area to a load in the safe area.. HART-transparent, no-load voltage: 15 V DC, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
In approx. 8 working days available in United Kingdom
MACX MCR-EX-SL-SD-24-48-LP-SP - Solenoid driver
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
In approx. 6 working days available in United Kingdom
MACX MCR-EX-SL-SD-21-60-LP-SP - Solenoid driver
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Push-in connection.
In approx. 6 working days available in United Kingdom
MINI MCR-EX-NAM-RO-PT - Isolation switch amplifier
Ex i-NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 1 solid-state relay at the output (passive). number of channels: 1, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
In approx. 6 working days available in United Kingdom
MACX MCR-EX-SL-SD-21-25-LP - Solenoid driver
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.
In approx. 26 working days available in United Kingdom
MACX MCR-EX-AP-RTD-RTD-SP - Temperature measuring transducer
Ex i-Resistance isolator for intrinsically safe operation of Pt 100 resistance thermometers in 2, 3, or 4-conductor technology and resistance-type sensors. The values measured at the Ex i input are transmitted 1:1 to the non Ex i output. number of channels: 1, Standard configuration, 3-way isolation, Push-in connection
Please contact us for more information.
MACX MCR-EX-TC-I-C - Temperature measuring transducer
Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Order configuration, freely programmable. 3-way isolation, SIL.
Made to order
Product cannot be cancelled or returned
2924809
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
Made to order
MACX MCR-EX-SL-NAM-NAM - Isolation switch amplifier
2866006
Ex i NAMUR isolation amplifier for operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive in accordance with EN 60947-5-6), line fault transparency, up to SIL 2 in accordance with IEC 61508, screw connection
MINI MCR-EX-SD-20-25-LP-PT - Solenoid driver
1157868
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 20 V DC, current limitation: 25 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MINI MCR-EX-SD-21-48-LP - Solenoid driver
2908810
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 21 V DC, current limitation: 48 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-SD-16-50-LFD-PT - Solenoid driver
1175904
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 16 V DC, current limitation: 50 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MINI MCR-EX-SD-20-25-LP - Solenoid driver
1157867
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 20 V DC, current limitation: 25 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-SD-16-50-LP - Solenoid driver
1157869
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 16 V DC, current limitation: 50 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-AP-2REL-2DI-LP - Relay module
1292331
Ex i-Relay module isolates binary Ex i and non Ex i signal and control circuits, and is used for intrinsically safe activation of Ex i field currents via one changeover contact relay per channel. number of channels: 2, Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Screw connection
MACX MCR-EX-AP-2T-2I-SP - Temperature measuring transducer
1290849
Ex i-Temperature transducer, input signals from resistance thermometers in 2, 3, or 4-conductor technology, thermocouples, and mV sources are converted into active 0 mA / 4 mA ... 20 mA non Ex i signals. number of channels: 2, Standard configuration, 5-way isolation, Push-in connection
MACX MCR-EX-RTD-I-SP-C - Temperature measuring transducer
1052652
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, order configuration.
MACX MCR-EX-AP-RPSS-I-IR-SP - Power/input isolating amplifier
1290776
Ex i-Feed and input signal conditioner with 2 limit value relays, feeds 2-, 3-, and 4-conductor measuring transducer, transmits 1:1 passive or active 0 mA/4 mA ... 20 mA input signals and has 2 configurable limit value outputs. number of channels: 1, HART-transparent, Standard configuration, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Push-in connection
MACX MCR-EX-SL-RPSSI-2I-1S - Repeater power supply
2908855
Ex i-Measuring transducer repeater power supply and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active electrically isolated signals from the Ex area to two loads. number of channels: 1, HART-transparent, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 2, Performance Level (ISO 13849): d / KAT 2, Systematic Capability: 3, Screw connection
MINI MCR-EX-SD-16-50-LFD - Solenoid driver
1175902
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 16 V DC, current limitation: 50 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-AP-IDS-2I-2I-LP - Output signal conditioner
1291963
Ex i-Output isolator isolates and transmits 0 mA / 4 mA ... 20 mA signals with intrinsic safety in potentially explosive areas. Suitable for fire and gas detectors. number of channels: 2, HART-transparent, no-load voltage: 25 V, Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-SD-16-50-LP-PT - Solenoid driver
1157870
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 16 V DC, current limitation: 50 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MINI MCR-EX-SD-21-48-LP-PT - Solenoid driver
2908811
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 21 V DC, current limitation: 48 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MINI MCR-EX-SD-23-38-LP-PT - Solenoid driver
1277114
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 23 V DC, current limitation: 38 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MACX MCR-EX-T-UI-UP-SP-C - Temperature measuring transducer
2924692
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
MINI MCR-EX-IDS-I-I - Output signal conditioner
2908805
Ex i-Output signal conditioner for isolating and transmitting 0 mA / 4 mA ... 20 mA signals from the controller to an intrinsically safe load in the Ex area. HART-transparent, no-load voltage: 27 V DC, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-SD-21-48-LFD - Solenoid driver
1175877
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 21 V DC, current limitation: 48 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-SD-20-25-LFD - Solenoid driver
1175891
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 20 V DC, current limitation: 25 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-NAM-2T - Isolation switch amplifier
1157852
Ex i-NAMUR signal conditioner for operating proximity sensors and switches in the Ex area. The signals are transmitted to the safe area via 2 transistor outputs (passive). Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-AP-RTD-RTD - Temperature measuring transducer
1291894
Ex i-Resistance isolator for intrinsically safe operation of Pt 100 resistance thermometers in 2, 3, or 4-conductor technology and resistance-type sensors. The values measured at the Ex i input are transmitted 1:1 to the non Ex i output. number of channels: 1, Standard configuration, 3-way isolation, Screw connection
MINI MCR-EX-SD-20-25-LFD-PT - Solenoid driver
1175897
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 20 V DC, current limitation: 25 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MACX MCR-EX-AP-2SD-25-35-LP - Solenoid driver
1291176
Ex i-Solenoid driver for intrinsically safe activation of Ex i solenoid valves, alarm transmitters, or displays installed in potentially explosive areas. number of channels: 2, Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-AP-2F-2I-SP - Frequency measuring transducer
1290533
Ex i-Frequency transducer, the frequencies measured at the Ex i inputs (0.001 Hz ... 20 kHz) are output as 0 mA / 4 mA ... 20 mA non Ex i signals. number of channels: 2, Standard configuration, 5-way isolation, Push-in connection
MACX MCR-EX-AP-2F-2I - Frequency measuring transducer
1290530
Ex i-Frequency transducer, the frequencies measured at the Ex i inputs (0.001 Hz ... 20 kHz) are output as 0 mA / 4 mA ... 20 mA non Ex i signals. number of channels: 2, Standard configuration, 5-way isolation, Screw connection
MINI MCR-EX-NAM-T - Isolation switch amplifier
2908807
Ex i-NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 1 transistor output (passive). Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-AP-2T-2I - Temperature measuring transducer
1290780
Ex i-Temperature transducer, input signals from resistance thermometers in 2, 3, or 4-conductor technology, thermocouples, and mV sources are converted into active 0 mA / 4 mA ... 20 mA non Ex i signals. number of channels: 2, Standard configuration, 5-way isolation, Screw connection
MINI MCR-EX-SD-23-38-LFD-PT - Solenoid driver
1277119
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 23 V DC, current limitation: 38 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MACX MCR-EX-SL-SD-21-25-LFD-SP - Solenoid driver
2905674
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 21.1 V, current limitation at 25.1 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; Push-in connection.
MACX MCR-EX-AP-RPSS-I-I - Power/input isolating amplifier
1291191
Ex i-Feed and input signal conditioner feeds 2-, 3- and 4-conductor measuring transducer and transmits 1:1 passive or active 0 mA / 4 mA ... 20 mA Ex i input signals as active non Ex i output signal. number of channels: 1, HART-transparent, Standard configuration, 3-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-AP-2REL-2DI-LP-SP - Relay module
1292332
Ex i-Relay module isolates binary Ex i and non Ex i signal and control circuits, and is used for intrinsically safe activation of Ex i field currents via one changeover contact relay per channel. number of channels: 2, Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Push-in connection
MACX MCR-EX-AP-RPSS-I-IR - Power/input isolating amplifier
1290774
Ex i-Feed and input signal conditioner with 2 limit value relays, feeds 2-, 3-, and 4-conductor measuring transducer, transmits 1:1 passive or active 0 mA/4 mA ... 20 mA input signals and has 2 configurable limit value outputs. number of channels: 1, HART-transparent, Standard configuration, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Screw connection
MINI MCR-EX-SD-23-38-LFD - Solenoid driver
1277116
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 23 V DC, current limitation: 38 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MINI MCR-EX-SD-23-38-LP - Solenoid driver
1277111
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 23 V DC, current limitation: 38 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
MACX MCR-EX-SL-NAM-NAM-SP - Isolation switch amplifier
2924883
Ex i NAMUR isolation amplifier for operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive in accordance with EN 60947-5-6), line fault transparency, up to SIL 2 in accordance with IEC 61508, Push-in connection
MINI MCR-EX-SD-21-48-LFD-PT - Solenoid driver
1175884
Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 21 V DC, current limitation: 48 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MACX MCR-EX-SL-SD-23-48-LFD-SP - Solenoid driver
2924870
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 in accordance with IEC 61508, Push-in connection
MACX MCR-EX-SL-SD-24-48-LFD-SP - Solenoid driver
2906156
Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508, Push-in connection.
MACX MCR-EX-AP-2SD-25-35-LP-SP - Solenoid driver
1291186
Ex i-Solenoid driver for intrinsically safe activation of Ex i solenoid valves, alarm transmitters, or displays installed in potentially explosive areas. number of channels: 2, Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
MACX MCR-EX-AP-IDS-2I-2I-LP-SP - Output signal conditioner
1291983
Ex i-Output isolator isolates and transmits 0 mA / 4 mA ... 20 mA signals with intrinsic safety in potentially explosive areas. Suitable for fire and gas detectors. number of channels: 2, HART-transparent, no-load voltage: 25 V, Standard configuration, Loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection