Bộ nguồn 1AC 24VDC 20A Phoenix Contact UNO2-PS/1AC/24DC/480W - 2910105
Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 20 A, adjustable from 24 V DC ... 28 V DC
Thông số kỹ thuật
Input data
| AC operation |
| Supply system configuration |
Star network (TN, TT, IT (PE)) |
| Nominal input voltage range |
100 V AC ... 240 V AC |
| Input voltage range |
100 V AC ... 240 V AC -15 % ... +10 % |
| Derating |
< 90 V AC (1 %/V) |
| Typical national grid voltage |
120 V AC |
| 230 V AC |
| Voltage type of supply voltage |
AC |
| Inrush current |
typ. 15 A (at 25 °C) |
| Inrush current integral (I2t) |
< 1 A2s |
| Frequency range (fN) |
50 Hz ... 60 Hz ±10 % |
| Mains buffering time |
typ. 17 ms (120 V AC) |
| typ. 18 ms (230 V AC) |
| Current consumption |
5.4 A (100 V AC) |
| 4.4 A (120 V AC) |
| 2.3 A (230 V AC) |
| 2.2 A (240 V AC) |
| Protective circuit |
Transient surge protection; Varistor, gas-filled surge arrester |
| Switch-on time |
typ. 1 s |
| Device mains fuse |
8 A internal (device protection), fast-blow |
| Recommended breaker for input protection |
10 A ... 16 A (Characteristic B, C, D, K or comparable) |
| Discharge current to PE |
< 3.5 mA |
Output data
| Efficiency |
typ. 93 % (120 V AC) |
| typ. 94.6 % (230 V AC) |
| Nominal output voltage |
24 V DC |
| Setting range of the output voltage (USet) |
24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) |
20 A |
| Short-circuit-proof |
yes |
| No-load proof |
yes |
| Derating |
55 °C ... 70 °C |
| Crest factor |
typ. 1.667 (120 V AC) |
| typ. 1.75 (230 V AC) |
| Output power (PN) |
480 W |
| Connection in parallel |
yes, for redundancy |
| Connection in series |
yes, for increased output voltage |
| Feedback voltage resistance |
≤ 35 V DC |
| Protection against overvoltage at the output (OVP) |
≤ 35 V DC |
| Residual ripple |
typ. 70 mVPP (with nominal values) |
| Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
| < 3 % (change in load, dynamic 10 % ... 90 %) |
| < 0.1 % (change in input voltage ±10 %) |
| Rise time |
< 1 s (UOut = 10 % ... 90 %) |
| Minimum no-load power dissipation |
< 2.9 W (120 V AC) |
| Maximum no-load power dissipation |
< 3 W (230 V AC) |
| Minimum nominal load power dissipation |
< 37 W (120 V AC) |
| Power loss nominal load max. |
< 28 W (230 V AC) |
| Signal relay 13/14 |
| Connection level |
3.x |
| Connection labeling |
3.1 (13), 3.2 (14) |
| Switch contact (floating) |
OptoMOS |
| Switching voltage |
max. 30 V AC/DC |
| max. 60 V DC |
| Current carrying capacity |
max. 50 mA |
| State condition |
UOUT > 0,9 x UN (Contact closed) |
| UOUT < 0,9 x UN (Contact open) |
Connection data
| Input |
| Position |
1.x |
| Identification |
1.1 (), 1.2 (L), 1.3 (N) |
| Conductor connection |
| Connection method |
Screw connection |
| rigid |
0.2 mm² ... 6 mm² |
| flexible |
0.2 mm² ... 4 mm² |
| flexible with ferrule without plastic sleeve |
0.25 mm² ... 4 mm² |
| flexible with ferrule with plastic sleeve |
0.25 mm² ... 4 mm² |
| rigid (AWG) |
24 ... 10 (Cu) |
| Stripping length |
8 mm |
| Tightening torque |
0.5 Nm ... 0.6 Nm |
| 4 lbf-in. ... 5 lbf-in. |
| Drive form screw head |
Slotted L |
| Output |
| Position |
2.x |
| Identification |
2.1, 2.2 (+), 2.3, 2.4 (-) |
| Conductor connection |
| Connection method |
Screw connection |
| rigid |
0.2 mm² ... 6 mm² |
| flexible |
0.2 mm² ... 4 mm² |
| flexible with ferrule without plastic sleeve |
0.25 mm² ... 4 mm² |
| flexible with ferrule with plastic sleeve |
0.25 mm² ... 4 mm² |
| rigid (AWG) |
24 ... 10 (Cu) |
| Stripping length |
8 mm |
| Tightening torque |
0.5 Nm ... 0.6 Nm |
| 4 lbf-in. ... 5 lbf-in. |
| Drive form screw head |
Slotted L |
| Signal |
| Position |
3.x |
| Identification |
3.1 (13), 3.2 (14) |
| Conductor connection |
| Connection method |
Screw connection |
| rigid |
0.2 mm² ... 6 mm² |
| flexible |
0.2 mm² ... 4 mm² |
| flexible with ferrule without plastic sleeve |
0.25 mm² ... 4 mm² |
| flexible with ferrule with plastic sleeve |
0.25 mm² ... 4 mm² |
| rigid (AWG) |
24 ... 10 (Cu) |
| Stripping length |
8 mm |
| Tightening torque |
0.5 Nm ... 0.6 Nm |
| 4 lbf-in. ... 5 lbf-in. |
| Drive form screw head |
Slotted L |
Signaling
| LED signaling |
| Types of signaling |
LED DC OK – signal state operation (UN = 24 V DC, IOut = IN) |
| Function |
Visual operating state display |
| Color |
green |
| LED off |
Supply voltage input AC not present (Off) |
| LED on (green), DC OK |
UOUT > 0,9 x UN (On (green), DC OK) |
| LED on (flashing green) DC OK < 0.9 x UN |
UOUT < 0,9 x UN (on (flashing green)) |
Electrical properties
| Number of phases |
1.00 |
| Insulation voltage input/output |
4 kV AC (type test) |
| 3 kV AC (routine test) |
| Insulation voltage input / PE |
3.5 kV AC (type test) |
| 2.4 kV AC (routine test) |
Product properties
| Product type |
Power supply |
| Product family |
UNO POWER |
| MTBF (IEC 61709, SN 29500) |
> 900000 h (25 °C) |
| > 530000 h (40 °C) |
| > 280000 h (55 °C) |
| Environmental protection directive |
RoHS Directive 2011/65/EU |
| WEEE |
| Reach |
| Insulation characteristics |
| Protection class |
I |
| Degree of pollution |
2 |
Dimensions
| Item dimensions |
| Width |
59 mm |
| Height |
130 mm |
| Depth |
129 mm |
| 125 mm (Device depth (DIN rail mounting)) |
| Installation dimensions |
| Installation distance right/left (active, passive) |
0 mm / 0 mm (POut ≥50% ) |
| Installation distance top/bottom (active, passive) |
30 mm / 30 mm (POut ≥50% ) |
Mounting
| Mounting type |
DIN rail mounting |
| Assembly instructions |
alignable: 0 mm horizontally, 30 mm vertically |
| Mounting position |
horizontal DIN rail NS 35, EN 60715 |
| With protective coating |
No |
Material specifications
| Flammability rating according to UL 94 |
V0 (Housing, terminal blocks) |
| Housing material |
Metal |
| Hood version |
Stainless steel |
| Side element version |
Aluminum |
| Foot latch material |
Sheet steel, zinc-plated |
| Housing material |
Aluminum (AlMg3) / sheet steel, zinc-plated |
Environmental and real-life conditions
| Ambient conditions |
| Degree of protection |
IP20 |
| Ambient temperature (operation) |
-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K) |
| Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
| Ambient temperature (start-up type tested) |
-40 °C |
| Maximum altitude |
≤ 3000 m (> 2000 m, Derating: 10 %/1000 m) |
| Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
| Shock (operation) |
18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Vibration (operation) |
10 Hz ... 50 Hz, amplitude ±0.2 mm |
| 50 Hz to 150 Hz, 2.3 g, 90 min. |
Standards and regulations
| Overvoltage category |
| EN 61010-1 |
II (≤ 3000 m) |
| Overvoltage category |
| EN 62477-1 |
III (≤3000 m) |
| Safety of power supply units up to 1100 V (insulation distances) |
| Standard designation |
Safety of power supply units up to 1100 V (insulation distances) |
| Standards/specifications |
DIN EN 61558-2-16 |
| Electrical safety |
| Standard designation |
Electrical safety |
| Standards/specifications |
IEC 61010-2-201 (SELV) |
| Electronic equipment for use in power installations |
| Standard designation |
Equipping high voltage installations with electronic equipment |
| Standards/specifications |
EN 50178/VDE 0160 (PELV) |
| Safety for measurement, control, and laboratory equipment |
| Standard designation |
Safety for equipment for measurement, control, and laboratory use |
| Standards/specifications |
IEC 61010-1 |
| Protective extra-low voltage |
| Standard designation |
Protective extra-low voltage |
| Standards/specifications |
IEC 61010-1 (SELV) |
| IEC 61010-2-201 (PELV) |
| Safe isolation |
| Standard designation |
Safe isolation |
| Standards/specifications |
IEC 61558-2-16 |
| IEC 61010-2-201 |
| Limitation of harmonic line currents |
| Standard designation |
Limitation of harmonic line currents |
| Standards/specifications |
EN 61000-3-2 |
| Mains voltage dips |
| Standard designation |
Requirement of the semiconductor industry with regard to mains voltage dips |
| Standards/specifications |
SEMI F47 - 0706 (185 V AC) |
Approvals
| UL |
| Identification |
UL/C-UL Listed UL 61010-1 |
| UL |
| Identification |
UL/C-UL Listed UL 61010-2-201 |
| UL |
| Identification |
UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
| SIQ |
| Identification |
CB scheme (IEC 61010-1, IEC 61010-2-201) |
EMC data
| Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
| Interference emission |
Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| EMC requirements for noise immunity |
EN 61000-6-2 |
| Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
| Conducted noise emission |
EN 55016 |
| EN 61000-6-3 (Class B) |
| Noise emission |
EN 55016 |
| EN 61000-6-3 (Class B) |
| Harmonic currents |
| Standards/regulations |
EN 61000-3-2 |
| EN 61000-3-2 (Class A) |
| Frequency range |
0 kHz ... 2 kHz |
| Flicker |
| Standards/regulations |
EN 61000-3-3 |
| Frequency range |
0 kHz ... 2 kHz |
| Electrostatic discharge |
| Standards/regulations |
EN 61000-4-2 |
| Electrostatic discharge |
| Contact discharge |
6 kV (Test Level 3) |
| Discharge in air |
8 kV (Test Level 3) |
| Comments |
Criterion A |
| Electromagnetic HF field |
| Standards/regulations |
EN 61000-4-3 |
| Electromagnetic HF field |
| Frequency range |
80 MHz ... 1 GHz |
| Test field strength |
10 V/m (Test Level 3) |
| Frequency range |
1 GHz ... 6 GHz |
| Test field strength |
10 V/m (Test Level 3) |
| Comments |
Criterion A |
| Fast transients (burst) |
| Standards/regulations |
EN 61000-4-4 |
| Fast transients (burst) |
| Input |
4 kV (Test Level 4 - asymmetrical) |
| Output |
2 kV (Test Level 3 - asymmetrical) |
| Comments |
Criterion A |
| Surge voltage load (surge) |
| Standards/regulations |
EN 61000-4-5 |
| Input |
2 kV (Test Level 4 - symmetrical) |
| 4 kV (Test Level 4 - asymmetrical) |
| Output |
1 kV (Test Level 3 - symmetrical) |
| 2 kV (Test Level 3 - asymmetrical) |
| Comments |
Criterion A |
| Conducted interference |
| Standards/regulations |
EN 61000-4-6 |
| Conducted interference |
| Input/Output |
asymmetrical |
| Frequency range |
0.15 MHz ... 80 MHz |
| Comments |
Criterion A |
| Voltage |
10 V (Test Level 3) |
| Voltage dips |
| Standards/regulations |
EN 61000-4-11 |
| Voltage |
230 V AC |
| Frequency |
50 Hz |
| Voltage dip |
70 % |
| Number of periods |
25 / 30 periods |
| Comments |
Criterion A |
| Voltage dip |
40 % |
| Number of periods |
12 periods |
| Additional text |
Test Level 2 |
| Comments |
Criterion A |
| Voltage dip |
0 % |
| Number of periods |
1 period |
| Additional text |
Test Level 2 |
| Comments |
Criterion B |
| Criteria |
| Criterion A |
Normal operating behavior within the specified limits. |
| Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Commercial data
| Item number |
2910105 |
| Packing unit |
1 pc |
| Minimum order quantity |
1 pc |
| Sales key |
CM15 |
| Product key |
CMPV13 |
| Catalog page |
Page 268 (C-4-2019) |
| GTIN |
4055626456652 |
| Weight per piece (including packing) |
1,252.4 g |
| Weight per piece (excluding packing) |
1,084 g |
| Customs tariff number |
85044095 |
| Country of origin |
TH |
Classifications
ECLASS
| ECLASS-11.0 |
27040701 |
| ECLASS-13.0 |
27040701 |
| ECLASS-12.0 |
27040701 |
ETIM
UNSPSC
Approvals
IECEE CB Scheme
Approval ID: SI-8862
UL Listed
Approval ID: FILE E 123528
cUL Listed
Approval ID: FILE E 123528
EAC
Approval ID: RU S-DE.BL08.W.00764
cUL Listed
Approval ID: FILE E 199827
UL Listed
Approval ID: FILE E 199827
cULus Listed
cULus Listed
Environmental product compliance
| |
| REACh SVHC |
Lead 7439-92-1 |
| |
| China RoHS |
Environmentally Friendly Use Period = 25; |
| For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |
- Tài liệu kỹ thuật Phoenix Contact UNO2-PS/1AC/24DC/480W - 2910105
ở đây.
Tham khảo thêm các model khác cùng loại:
UNO2-PS/1AC/24DC/480W - Power supply unit
2910105
Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 20 A, adjustable from 24 V DC ... 28 V DC
UNO2-PS/1AC/24DC/240W - Power supply unit
1096432
Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 10 A, adjustable from 24 V DC ... 28 V DC
UNO2-PS/1AC/24DC/120W - Power supply unit
1110466
Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 5 A, adjustable from 24 V DC ... 28 V DC
UNO2-PS/1AC/48DC/240W - Power supply unit
1110155
Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 48 V DC / 5 A, adjustable from 42 V DC ... 56 V DC
UNO2-PS/1AC/24DC/960W - Power supply unit
1110043
Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 40 A, adjustable from 24 V DC ... 28 V DC
UNO-PS/1AC/24DC/ 60W - Power supply unit
2902992
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/60 W
UNO-PS/1AC/24DC/ 30W - Power supply unit
2902991
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/30 W
UNO-PS/1AC/24DC/150W - Power supply unit
2904376
Primary-switched UNO power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/150 W
UNO-PS/1AC/24DC/100W - Power supply unit
2902993
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W
UNO-PS/2AC/24DC/90W/C2LPS - Power supply unit
2904371
Primary-switched UNO POWER power supply for DIN rail mounting, input: 2-phase, output: 24 V DC/90 W
UNO-PS/1AC/24DC/90W/C2LPS - Power supply unit
2902994
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/90 W
UNO-PS/1AC/12DC/ 30W - Power supply unit
2902998
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/30 W
UNO-PS/1AC/ 5DC/ 25W - Power supply unit
2904374
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 5 V DC/25 W
UNO-PS/1AC/12DC/ 55W - Power supply unit
2902999
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/55 W
UNO-PS/1AC/12DC/100W - Power supply unit
2902997
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/100 W
UNO-PS/1AC/ 5DC/ 40W - Power supply unit
2904375
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 5 V DC/40 W
UNO-PS/1AC/15DC/30W - Power supply unit
2903000
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/30 W
UNO-PS/1AC/48DC/100W - Power supply unit
2902996
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 48 V DC/100 W
UNO-PS/1AC/15DC/ 55W - Power supply unit
2903001
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/55 W
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W
UNO-PS/1AC/48DC/ 60W - Power supply unit
2902995
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 48 V DC/60 W
UNO-PS/1AC/12DC/ 55W/H - Power supply unit
1088850
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/55 W
UNO-PS/1AC/15DC/100W - Power supply unit
2903002
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/100 W