| Width | 68 mm |
| Height | 130 mm |
| Depth | 160 mm |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Degree of pollution | 2 |
| Installation height | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Nominal input voltage range | 100 V AC ... 240 V AC |
| 110 V DC ... 250 V DC | |
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| 99 V DC ... 275 V DC | |
| Dielectric strength maximum | ≤ 300 V AC 15 s |
| AC frequency range | 50 Hz ... 60 Hz ±10 % |
| Discharge current to PE | < 3.5 mA |
| Current consumption | 5.6 A (100 V AC) |
| 5.4 A (120 V AC) | |
| 2.6 A (230 V AC) | |
| 2.4 A (240 V AC) | |
| Nominal power consumption | 34 W |
| Inrush surge current | 20 A (at 25 °C) |
| Mains buffering | > 10 ms (120 V AC) |
| > 15 ms (230 V AC) | |
| Input fuse | 10 A (internal (device protection)) |
| Choice of suitable circuit breakers | 10 A ... 16 A (Characteristics B, C, D, K) |
| Type of protection | Transient surge protection |
| Protective circuit/component | Varistor |
| Nominal output voltage | 48 V DC ±1 % |
| Setting range of the output voltage (USet) | 36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted) |
| Nominal output current (IN) | 10 A |
| Dynamic Boost (IDyn.Boost) | 15 A (5 s) |
| Derating | > 60 °C ... 70 °C (2.5%/K) |
| Connection in parallel | Yes, for redundancy and increased capacity |
| Connection in series | yes |
| Feedback resistance | ≤ 60 V DC |
| Circuit breaker against surge voltage at output by invasive foreign matter | ≤ 60 V DC |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
| < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 50 mVPP (with nominal values) |
| Output power | 480 W |
| Typical response time | < 1 s |
| Peak switching voltages nominal load | < 1000 mVPP |
| Maximum power dissipation in no-load condition | < 5.7 W (230 V) |
| Power loss nominal load max. | < 44 W |
| Net weight | 1.4 kg |
| Efficiency | > 93 % (for 230 V AC and nominal values) |
| Insulation voltage input/output | 3 kV AC |
| 1.5 kV AC | |
| Protection class | I (in closed control cabinet) |
| Degree of protection | IP20 |
| MTBF (IEC 61709, SN 29500) | > 1800000 h (25 °C) |
| > 800000 h (40 °C) | |
| > 480000 h (60 °C) | |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions | Can be aligned: Horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
| Connection method | Push-in connection |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
| Connection method | Push-in connection |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 10 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 6 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 8 |
| Stripping length | 15 mm |
| Connection method | Push-in connection |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Noise emission | EN 55011 (EN 55022) |
| Noise immunity | EN 61000-6-2:2005 |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 4 kV (Test Level 2) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency range | 1.4 GHz ... 2 GHz |
| Test field strength | 3 V/m (Test Level 2) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-5 |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Standards/regulations | EN 61000-6-3 |
| EN 61000-4-6 | |
| Frequency range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V (Test Level 3) |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) |
| Standard - Electrical safety | IEC 60950-1/VDE 0805 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
| UL approvals | UL Listed UL 508 |
| UL/C-UL Recognized UL 60950-1 | |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| 15 Hz ... 150 Hz, 4g, 90 min. | |
| Rail applications | EN 50121-4 |
| Assembly instructions | Can be aligned: Horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| eCl@ss 4.0 | 27040702 |
| eCl@ss 4.1 | 27040702 |
| eCl@ss 5.0 | 27049002 |
| eCl@ss 5.1 | 27049002 |
| eCl@ss 6.0 | 27049002 |
| eCl@ss 7.0 | 27049002 |
| eCl@ss 8.0 | 27049002 |
| eCl@ss 9.0 | 27040701 |
| ETIM 4.0 | EC002540 |
| ETIM 5.0 | EC002540 |
| ETIM 6.0 | EC002540 |
| UNSPSC 13.2 | 39121004 |
Siemens 6EP3310-6SB00-0AY0 | LOGO!POWER 5 V / 3 A Stabilized power supply -BộGiá tốt nhất xem...0909186879 Email
Siemens 6EP3333-7LB00-0AX0 | SITOP PSU6200 3.7 A NEC class II -Bộ nguồnGiá tốt nhất xem...0909186879 Email
Bộ nguồn Phoenix Contact UNO-PS/1AC/24DC/240W - 2904372 | 1-phase 24VDC 240WGiá tốt nhất xem...0909186879 Email
Bộ nguồn Phoenix Contact STEP-PS/ 1AC/24DC/0.5 - 2868596 | 1-phase 24VDC 0.5AGiá tốt nhất xem...0909186879 Email
Bộ nguồn Phoenix Contact STEP-PS/ 1AC/24DC/4.2 - 2868664 | 1-phase 24VDC 0.5AGiá tốt nhất xem...0909186879 Email
Bộ nguồn Phoenix Contact TRIO-PS/1AC/24DC/20 - 2866381 | 1AC 24VDC 20AGiá tốt nhất Xem...0909186879 Email
Bộ nguồn Phoenix Contact TRIO-PS/1AC/24DC/10 - 2866323 | 1AC 24VDC 10A Giá tốt nhất Xem...0909186879 Email
Bộ nguồn Phoenix Contact TRIO-PS/1AC/24DC/ 5 - 2866310 | 1P 24VDC 5AGiá tốt nhất Xem...0909186879 Email
Bộ nguồn 24vDC 10A 1AC 120/230V - Siemens - SITOP PSU100S 24 V/10 A - 6EP1334-2BA20Giá tốt nhất Xem...0909186879 Email
Bộ nguồn Siemens 6EP1336-2BA10 | SITOP PSU100S 20A | 120/230VAC 24VDC 20AGiá tốt nhất Xem...0909186879 Email
Bộ nguồn 24vDC-60W Phoenix Contact Power supply unit - UNO-PS/1AC/24DC/ 60W - 2902992Giá tốt nhất Xem...0909186879 Email
Module chuyển đổi nguồn dự phòng Redundancy module 24vDC 20A - Siemens - 6EP1961-3BA21Giá tốt nhất Xem...0909186879 Email
Bộ nguồn Siemens 6EP1333-2BA20 | SITOP PSU100S 24 V/5 A | 120/230VAC 24VDC 5AGiá tốt nhất Xem...0909186879 Email
Bộ nguồn 24vDC-100W Phoenix Contact Power supply unit - UNO-PS/1AC/24DC/100W - 2902993Giá tốt nhất Xem...0909186879 Email