Khởi động động cơ hybrid Phoenix Contact ELR W3- 24DC/500AC- 9I - 2297057

Khởi động động cơ hybrid Phoenix Contact ELR W3- 24DC/500AC- 9I - 2297057

175
Nhà sản xuất:

Phoenix Contact

;   

Xuất xứ: Germany

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Khởi động động cơ hybrid Phoenix Contact ELR W3- 24DC/500AC- 9I - 2297057

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.

 

Product properties

Product type Hybrid motor starters
Product family CONTACTRON
Operating mode 100% operating factor
 

Electrical properties

Number of phases 3
Motor starter type Reversing starter
Maximum power dissipation for nominal condition 13.5 W
Switching frequency ≤ 2 Hz (Load-dependent)
Maximum power dissipation 14.6 W
Minimum power dissipation 1.1 W
Supply
Rated control circuit supply voltage US 24 V DC
Control supply voltage range 19.2 V DC ... 30 V DC
Rated control supply current IS 40 mA
Protective circuit Surge protection
Reverse polarity protection
Insulation characteristics
Rated insulation voltage 500 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
Basic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
 

Input data

Control
Input name Control input right/left
Rated actuating voltage UC 24 V DC
Triggering voltage range 19.2 V DC ... 30 V DC
Rated actuating current IC 5 mA
Switching threshold 9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level < 5 V DC (For EMERGENCY STOP)
Typical response time < 35 ms
Typical turn-off time < 40 ms
 

Output data

AC output
Rated operating voltage Ue 500 V AC
Operating voltage range 42 V AC ... 550 V AC
Rated operating current Ie 9 A (AC-51)
6.5 A (AC-53a)
Mains frequency 50/60 Hz
Load current range 1.5 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10A
Cooling time 20 min. (for auto reset)
Leakage current 0 mA
Residual voltage < 0.5 V
Surge current 100 A (t = 10 ms)
Protective circuit Surge protection
Acknowledge output
Note Confirmation: floating change-over contact, signal contact
Contact switching type 1 changeover contact
Switching capacity in accordance with IEC 60947-5-1 3 A (230 V, AC15)
2 A (24 V, DC13)
Residual voltage < 0.5 V
 

Connection data

Control circuits
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Load circuit
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
 

Signaling

Status display Yellow LED
Operating voltage display Green LED
Error indication Red LED
 

Dimensions

Width 22.5 mm
Height 107 mm
Depth 114 mm
 

Material specifications

Flammability rating according to UL 94 V0 (Housing)
 

Environmental and real-life conditions

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m
 

Approvals

ATEX
Identification  II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]
Certificate PTB 07 ATEX 3145
UL approval
Certificate NLDX.E228652
Safety Integrity Level (SIL, IEC 61508)
Identification ≤ 3
Note Safe shutdown
Safety Integrity Level (SIL, IEC 61508)
Identification 2
Note Motor protection
Performance Level (ISO 13849)
Identification ≤ e
Note Safe shutdown
Category (ISO 13849)
Identification ≤ 3
Note Safe shutdown
UL data
SCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA 6.5 A (500 V AC)
Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category code NLDX
 

Standards and regulations

Standards/regulations
Standards/regulations EN 60947
IEC 61508
ISO 13849
 

Mounting

Mounting type DIN rail mounting
Assembly instructions Can be aligned with spacing = 20 mm
Mounting position Vertical (horizontal DIN rail)
 

Commercial data

Item number 2297057
Packing unit 1 pc
Minimum order quantity 1 pc
Product key CK7414
Catalog page Page 19 (C-7-2013)
GTIN 4046356170581
Weight per piece (including packing) 310 g
Weight per piece (excluding packing) 230.62 g
Customs tariff number 85371098
Country of origin DE
 

Classifications

ECLASS

ECLASS-11.0 27370905
ECLASS-12.0 27370905
ECLASS-13.0 27370905
 

ETIM

ETIM 9.0 EC001037
 

UNSPSC

UNSPSC 21.0 25173900
 

Approvals

IECEE CB Scheme

Approval ID: DE1-55728
 

EAC

Approval ID: RU*C-DE.*08.B.00520*
 

DNV GL

Approval ID: TAA00002HK
 

UL Listed

Approval ID: FILE E 323771
 

CCC

Approval ID: 2016010304871315
 

cUL Listed

Approval ID: FILE E 323771
 

cUL Listed

Approval ID: FILE E 228652
 

UL Listed

Approval ID: FILE E 228652
 

ATEX

Approval ID: PTB 07 ATEX 3145
 

Environmental product compliance

EU RoHS
Fulfills EU RoHS substance requirements Yes
Exemption 7(a), 7(c)-I
China RoHS
Environment friendly use period (EFUP) EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
EU REACH SVHC
REACH candidate substance (CAS No.) Lead (CAS: 7439-92-1)
SCIP 34de185b-1e0e-472f-b5a0-0f1ce1f4a753



- Tài liệu kỹ thuật Phoenix Contact ELR W3- 24DC/500AC- 9I - 2297057 ở đây.


Tham khảo thêm các model khác cùng loại:
ELR W3- 24DC/500AC- 2I - Hybrid motor starter
2297031

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection
ELR H5-I-SC- 24DC/500AC-2 - Hybrid motor starter
2900574

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-IES-SC- 24DC/500AC-9 - Hybrid motor starter
2900569

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
ELR H3-I-SC- 24DC/500AC-2 - Hybrid motor starter
2900543

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-IES-SC- 24DC/500AC-2 - Hybrid motor starter
2900567

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and, screw connection.
ELR W3- 24DC/500AC- 9I - Hybrid motor starter
2297057

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR H5-IES-PT- 24DC/500AC-2 - Hybrid motor starter
2903904

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-I-SC- 24DC/500AC-9 - Hybrid motor starter
2900576

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H5-IES-SC- 24DC/500AC-2 - Hybrid motor starter
2900414

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3 / PL e and screw connection
ELR H3-I-PT- 24DC/500AC-2 - Hybrid motor starter
2903922

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT- 24DC/500AC-9 - Hybrid motor starter
2903906

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter
2905139

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H5-I-PT- 24DC/500AC-2 - Hybrid motor starter
2903910

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-SC- 24DC/500AC-9 - Hybrid motor starter
2900421

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
EM-MODBUS-GATEWAY-IFS - Data interface
2901528

Gateway for the connection of up to 32 INTERFACE system devices via Modbus/TCP to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR H3-IES-PT- 24DC/500AC-2 - Hybrid motor starter
2903916

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
EM-PNET-GATEWAY-IFS - Data interface
2904472

Gateway for the connection of up to 32 INTERFACE system devices via PROFINET to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
EM-PSAFE-GATEWAY-IFS - Data interface
1188207

Gateway for connecting up to 15 INTERFACE system devices to a higher-level secure controller via PROFIsafe. The system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H3-I-SC- 24DC/500AC-9 - Hybrid motor starter
2900545

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-IES-PT- 24DC/500AC-9 - Hybrid motor starter
2903918

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H5-I-PT- 24DC/500AC-9 - Hybrid motor starter
2903912

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT-24DC/500AC-2-T - Hybrid motor starter
2906059

Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 2.4 A; connection method: Push-in connection
ELR H5-SC- 24DC/500AC-9 - Hybrid motor starter
2900538

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, and screw connection.
ELR H3-I-PT- 24DC/500AC-9 - Hybrid motor starter
2903924

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-I-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903908

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
EM-PB-GATEWAY-IFS - Data interface
2297620

Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via PROFIBUS DP. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR W3-230AC/500AC- 9I - Hybrid motor starter
2297060

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection
ELR H5-IES-PT-24DC/500AC-9-T - Hybrid motor starter
2906060

Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 9 A; connection method: Push-in connection
ELR W3-230AC/500AC- 2I - Hybrid motor starter
2297044

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2 A output current, with 230 V AC control voltage, adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection
ELR H3-IES-PT/500AC-9-IOL - Hybrid motor starter
2908672

Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IES-PT/500AC-9-IFS - Hybrid motor starter
2905140

Networkable hybrid motor starter for reversing of 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H3-IES-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900566

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
ELR H5-IS-SC- 24DC/500AC-3-P - Hybrid motor starter
2908699

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IS-PT- 24DC/500AC-3-P - Hybrid motor starter
2909570

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT-24DC/500AC-9-T - Hybrid motor starter
2906064

Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 9 A; connection method: Push-in connection
ELR H5-IS-PT- 24DC/500AC-9-P - Hybrid motor starter
2909567

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT/500AC-3-IOL - Hybrid motor starter
2908671

Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-I-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900573

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H5-IES-SC/500AC-3-IFS - Hybrid motor starter
2905152

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection, DIN rail connector provided.
ELR H5-IES-SC/500AC-9-IFS - Hybrid motor starter
2905153

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection, DIN rail connector provided.
ELR H5-IES-SC-230AC/500AC-9 - Hybrid motor starter
2900422

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e
ELR H5-IES-PT- 24DC/500AC-3-P - Hybrid motor starter
2909556

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-SC/500AC-9-IFS - Hybrid motor starter
2905156

Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 9 A, emergency stop function, adjustable overload shutdown, and screw connection, DIN rail connector provided.
ELR H3-SC- 24DC/500AC-9 - Hybrid motor starter
2900530

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage and screw connection.
ELR H5-IES-PT/500AC-3-IOL - Hybrid motor starter
2908669

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IS-SC- 24DC/500AC-9-P - Hybrid motor starter
2908697

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3 / PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903920

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903902

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-IES-SC/500AC-06-IFS - Hybrid motor starter
2905151

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3/PL e and screw connection, DIN rail connector provided.
ELR H5-I-SC-24DC/500AC-2-L - Hybrid motor starter
2905513

Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
ELR H3-IES-SC-230AC/500AC-9 - Hybrid motor starter
2900570

Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 9 A output current, emergency stop function, and adjustable overload shutdown.
ELR H5-IES-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900582

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR H3-IES-PT-24DC/500AC-06-T - Hybrid motor starter
2906061

Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 600 mA; connection method: Push-in connection
ELR H5-IES-PT/500AC-06-IFS - Hybrid motor starter
2905138

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H5-IES-PT-24DC/500AC-06-T - Hybrid motor starter
2906058

Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 600 mA; connection method: Push-in connection
ELR H5-IES-SC-230AC/500AC-2 - Hybrid motor starter
2900420

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 230 V AC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e
ELR H3-IES-SC-230AC/500AC-2 - Hybrid motor starter
2900568

Hybrid motor starter for starting 3~  AC motors up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown.
ELR H5-ES-SC- 24DC/500AC-2 - Hybrid motor starter
2900559

Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, and emergency stop function.
ELR H3-IES-PT/500AC-3-IFS - Hybrid motor starter
2905142

Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
ELR H3-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903914

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H3-I-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900542

Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-I-PT- 24DC/500AC-9-P - Hybrid motor starter
2909561

Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-ES-SC- 24DC/500AC-9 - Hybrid motor starter
2900561

Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 9 A output current, and emergency stop function.
ELR H3-I-SC- 24DC/500AC-3-P - Hybrid motor starter
2908696

Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
EM-ETH-GATEWAY-IFS - Data interface
2901988

Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via EtherNet/IP™. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR H5-I-SC- 24DC/500AC-3-P - Hybrid motor starter
2908695

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-IES-PT/500AC-9-IOL - Hybrid motor starter
2908670

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
EM-CAN-GATEWAY-IFS - Data interface
2901504

Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via CANopen®. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR H3-IS-PT- 24DC/500AC-9-P - Hybrid motor starter
2909568

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT- 24DC/500AC-9-P - Hybrid motor starter
2909555

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT/500AC-9-IFS - Hybrid motor starter
2905143

Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 9 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
ELR H3-IES-PT- 24DC/500AC-3-P - Hybrid motor starter
2909557

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H5-I-PT-24DC/500AC-2-L - Hybrid motor starter
1199926

Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
ELR H3-IES-PT-24DC/500AC-2-T - Hybrid motor starter
2906062

Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 2.4 A; connection method: Push-in connection
ELR H5-IES-PT- 24DC/500AC-9-P - Hybrid motor starter
2909554

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-PT- 24DC/500AC-3-P - Hybrid motor starter
2909563

Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-9-P02 - Hybrid motor starter
1160740

Modular hybrid motor starter for starting and reversing motors incl. motor protection and rotary field monitoring, input: 24 V DC, output: 3~, 500 V AC, 9 A, connection method: Push-in connection
EM-2RSC/21AU-R/L-P - Extension module
2908701

Relay extension module for ELR-...-P hybrid motor starters, feedback of forward and reverse running when control signal is present, screw connection, DIN rail connector included
ELR H5-IS-PT- 24DC/500AC-3-P - Hybrid motor starter
2909569

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-9-P - Hybrid motor starter
2909560

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-SC- 24DC/500AC-9-P - Hybrid motor starter
2908693

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-3-P - Hybrid motor starter
2909562

Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
EM-2RPT/21AU-R/L-P - Extension module
2909573

Relay extension module for ELR-...-P hybrid motor starters, feedback of forward and reverse running when control signal is present, Push-in connection, DIN rail connector included
ELR H3-IS-SC- 24DC/500AC-3-P - Hybrid motor starter
2908700

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-SC/500AC-3-IFS - Hybrid motor starter
2905155

Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and screw connection, DIN rail connector provided.
ELR H3-IS-SC- 24DC/500AC-9-P - Hybrid motor starter
2908698

Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-SC- 24DC/500AC-9-P - Hybrid motor starter
2908694

Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR W1/ 6-24DC - Reversing load relay
2982090

Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 10 - 30 V DC/6 A with a switch-over time of 80 ms
ELR DCR-PT-24DC-10 - Reversing load relay
1291655

Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 24 V DC/10 A with a switch-over time of 100 ms
ELR DCR-PT-24DC-3 - Reversing load relay
1291615

Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 24 V DC/3 A with a switch-over time of 100 ms
PLC-SC-ELR W1/ 2-24DC - Reversing load relay
2980539

PLC-INTERFACE as an electronic reversing load relay, consisting of PLC-BSC.../21 basic terminal block with screw connection and integrated circuit, for driving DC motors, with LED and protective circuit, output: 10 ... 30 V DC/2 A
ELR W1/ 6-24DC/RDT - Reversing load relay
2982757

Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 10 - 30 V DC/6 A with a switch-over time of 1 ms
PLC-PT-ELR W1/ 2-24DC - Reversing load relay
1069556

PLC-INTERFACE as an electronic reversing load relay, consisting of PLC-BPT.../21 basic terminal block with Push-in connection and integrated circuit, for driving DC motors, with LED display and protective circuit, output: 10 ... 30 V DC/2 A
ELR W1/ 2-24DC - Reversing load relay
2963598

Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit, output: 10-30 V DC/2 A
ELR W3/ 9-500 - Reversing load relay
2964186

Electronic reversing load relay, for direct driving of equipment in the 3-phase network, with light indicator and protection circuit, output: 110-550 V AC/3 x 9 A
ELR 1-SC-24DC/600AC-20 - Solid-state contactor
1032919

Single-phase solid-state contactor, input voltage: 24 V DC, output current: 20 A, zero voltage switch
ELR 1-SC-24DC/600AC-30 - Solid-state contactor
1032921

Single-phase solid-state contactor, input voltage: 24 V DC, output current: 30 A, zero voltage switch
ELR 1-SC-24DC/600AC-50 - Solid-state contactor
1032926

Single-phase solid-state contactor, input voltage: 24 V DC, output current: 50 A, zero voltage switch
ELR W2+1- 24DC/500AC-37 - Solid-state reversing contactor
2297374

Three-phase solid-state reversing contactor with 24 V DC input, 37 A output current, zero voltage switch, optionally with thermal fuse
ELR W3- 24DC/500AC- 9 - Solid-state reversing contactor
2297316

Three-phase solid-state reversing contactor with 24 V DC input, 9 A output current, zero voltage switch, optionally with thermal fuse
ELR W3- 24DC/500AC- 2 - Solid-state reversing contactor
2297293

Three-phase solid-state reversing contactor with 24 V DC input, 2 A output current, zero voltage switch, optionally with thermal fuse
ELR 1-SC-230AC/600AC-30 - Solid-state contactor
1032922

Single-phase solid-state contactor, input voltage: 230 V AC, output current: 30 A, zero voltage switch
ELR 1-SC-230AC/600AC-20 - Solid-state contactor
1032920

Single-phase solid-state contactor, input voltage: 230 V AC, output current: 20 A, zero voltage switch
ELR 1-SC-230AC/600AC-50 - Solid-state contactor
1032927

Single-phase solid-state contactor, input voltage: 230 V AC, output current: 50 A, zero voltage switch
CSS 0.55-3/3 - Speed starter
1201694

Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.55 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input
CSS 1.5-1/3-EMC - Speed starter
1201642

Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input, with integrated EMC filter
EM-CSS-SHIELDING-SET-SCC-35 - Shield connection
1451206

Accessories set for simple and reliable connection of cable shields to the CONTACTRON Speed Starter, consisting of a 35 mm shroud, 2 shield connection terminal blocks for the signal lines, and one shield connection terminal block for the motor cable.
CSS 1.5-3/3-EMC - Speed starter
1201696

Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input, with integrated EMC filter
CSS 1.5-3/3 - Speed starter
1201650

Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input
CSS 0.25-3/3-EMC - Speed starter
1201713

Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.25 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input, with integrated EMC filter
CSS 0.55-3/3-EMC - Speed starter
1201828

Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.55 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input, with integrated EMC filter
CSS 0.25-1/3 - Speed starter
1201132

Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 0.25 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input
EM-CSS-SHIELDING-SET-SCC-45 - Shield connection
1451208

Accessories set for simple and reliable connection of cable shields to the CONTACTRON Speed Starter, consisting of a 45 mm shroud, 2 shield connection terminal blocks for the signal lines, and one shield connection terminal block for the motor cable.
CSS 0.75-3/3 - Speed starter
1201695

Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.75 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input
CSS 0.37-1/3 - Speed starter
1201135

Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 0.37 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input
CSS 1.5-1/3 - Speed starter
1201511

Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input
CSS 0.75-3/3-EMC - Speed starter
1201829

Speed starter with soft start and co
Sản phẩm cùng loại
Gọi điện thoại