Khởi động động cơ hybrid Phoenix Contact ELR W3- 24DC/500AC- 9I - 2297057
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
Product properties
Product type |
Hybrid motor starters |
Product family |
CONTACTRON |
Operating mode |
100% operating factor |
Electrical properties
Number of phases |
3 |
Motor starter type |
Reversing starter |
Maximum power dissipation for nominal condition |
13.5 W |
Switching frequency |
≤ 2 Hz (Load-dependent) |
Maximum power dissipation |
14.6 W |
Minimum power dissipation |
1.1 W |
Supply |
Rated control circuit supply voltage US |
24 V DC |
Control supply voltage range |
19.2 V DC ... 30 V DC |
Rated control supply current IS |
40 mA |
Protective circuit |
Surge protection |
Reverse polarity protection |
Insulation characteristics |
Rated insulation voltage |
500 V |
Rated surge voltage |
6 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC |
Basic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC |
Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Input data
Control |
Input name |
Control input right/left |
Rated actuating voltage UC |
24 V DC |
Triggering voltage range |
19.2 V DC ... 30 V DC |
Rated actuating current IC |
5 mA |
Switching threshold |
9.6 V (“0” signal) |
19.2 V (“1” signal) |
Switching level |
< 5 V DC (For EMERGENCY STOP) |
Typical response time |
< 35 ms |
Typical turn-off time |
< 40 ms |
Output data
AC output |
Rated operating voltage Ue |
500 V AC |
Operating voltage range |
42 V AC ... 550 V AC |
Rated operating current Ie |
9 A (AC-51) |
6.5 A (AC-53a) |
Mains frequency |
50/60 Hz |
Load current range |
1.5 A ... 9 A (see to derating) |
Trigger characteristic in acc. with IEC 60947-4-2 |
Class 10A |
Cooling time |
20 min. (for auto reset) |
Leakage current |
0 mA |
Residual voltage |
< 0.5 V |
Surge current |
100 A (t = 10 ms) |
Protective circuit |
Surge protection |
Acknowledge output |
Note |
Confirmation: floating change-over contact, signal contact |
Contact switching type |
1 changeover contact |
Switching capacity in accordance with IEC 60947-5-1 |
3 A (230 V, AC15) |
2 A (24 V, DC13) |
Residual voltage |
< 0.5 V |
Connection data
Control circuits |
Connection method |
Screw connection |
Stripping length |
8 mm |
Screw thread |
M3 |
Conductor cross section rigid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Tightening torque |
0.5 Nm ... 0.6 Nm |
5 lbf-in. ... 7 lbf-in. |
Load circuit |
Connection method |
Screw connection |
Stripping length |
8 mm |
Screw thread |
M3 |
Conductor cross section rigid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Tightening torque |
0.5 Nm ... 0.6 Nm |
5 lbf-in. ... 7 lbf-in. |
Signaling
Status display |
Yellow LED |
Operating voltage display |
Green LED |
Error indication |
Red LED |
Dimensions
Width |
22.5 mm |
Height |
107 mm |
Depth |
114 mm |
Material specifications
Flammability rating according to UL 94 |
V0 (Housing) |
Environmental and real-life conditions
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C ... 70 °C (observe derating) |
Ambient temperature (storage/transport) |
-40 °C ... 80 °C |
Altitude |
≤ 2000 m |
Approvals
ATEX |
Identification |
II (2) G [Ex e] [Ex d] [Ex px] |
II (2) D [Ex t] [Ex p] |
Certificate |
PTB 07 ATEX 3145 |
UL approval |
Certificate |
NLDX.E228652 |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
≤ 3 |
Note |
Safe shutdown |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
2 |
Note |
Motor protection |
Performance Level (ISO 13849) |
Identification |
≤ e |
Note |
Safe shutdown |
Category (ISO 13849) |
Identification |
≤ 3 |
Note |
Safe shutdown |
UL data |
SCCR |
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) |
FLA |
6.5 A (500 V AC) |
Group installation |
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) |
Category code |
NLDX |
Standards and regulations
Standards/regulations |
Standards/regulations |
EN 60947 |
IEC 61508 |
ISO 13849 |
Mounting
Mounting type |
DIN rail mounting |
Assembly instructions |
Can be aligned with spacing = 20 mm |
Mounting position |
Vertical (horizontal DIN rail) |
Commercial data
Item number |
2297057 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product key |
CK7414 |
Catalog page |
Page 19 (C-7-2013) |
GTIN |
4046356170581 |
Weight per piece (including packing) |
310 g |
Weight per piece (excluding packing) |
230.62 g |
Customs tariff number |
85371098 |
Country of origin |
DE |
Classifications
ECLASS
ECLASS-11.0 |
27370905 |
ECLASS-12.0 |
27370905 |
ECLASS-13.0 |
27370905 |
ETIM
UNSPSC
Approvals
IECEE CB Scheme
Approval ID: DE1-55728
EAC
Approval ID: RU*C-DE.*08.B.00520*
DNV GL
Approval ID: TAA00002HK
UL Listed
Approval ID: FILE E 323771
CCC
Approval ID: 2016010304871315
cUL Listed
Approval ID: FILE E 323771
cUL Listed
Approval ID: FILE E 228652
UL Listed
Approval ID: FILE E 228652
ATEX
Approval ID: PTB 07 ATEX 3145
Environmental product compliance
EU RoHS |
Fulfills EU RoHS substance requirements |
Yes |
Exemption |
7(a), 7(c)-I |
China RoHS |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
EU REACH SVHC |
REACH candidate substance (CAS No.) |
Lead (CAS: 7439-92-1) |
SCIP |
34de185b-1e0e-472f-b5a0-0f1ce1f4a753 |
- Tài liệu kỹ thuật Phoenix Contact ELR W3- 24DC/500AC- 9I - 2297057
ở đây.
Tham khảo thêm các model khác cùng loại:
ELR W3- 24DC/500AC- 2I - Hybrid motor starter
2297031
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection
ELR H5-I-SC- 24DC/500AC-2 - Hybrid motor starter
2900574
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-IES-SC- 24DC/500AC-9 - Hybrid motor starter
2900569
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
ELR H3-I-SC- 24DC/500AC-2 - Hybrid motor starter
2900543
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-IES-SC- 24DC/500AC-2 - Hybrid motor starter
2900567
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and, screw connection.
ELR W3- 24DC/500AC- 9I - Hybrid motor starter
2297057
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR H5-IES-PT- 24DC/500AC-2 - Hybrid motor starter
2903904
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-I-SC- 24DC/500AC-9 - Hybrid motor starter
2900576
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H5-IES-SC- 24DC/500AC-2 - Hybrid motor starter
2900414
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3 / PL e and screw connection
ELR H3-I-PT- 24DC/500AC-2 - Hybrid motor starter
2903922
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT- 24DC/500AC-9 - Hybrid motor starter
2903906
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter
2905139
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H5-I-PT- 24DC/500AC-2 - Hybrid motor starter
2903910
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-SC- 24DC/500AC-9 - Hybrid motor starter
2900421
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
EM-MODBUS-GATEWAY-IFS - Data interface
2901528
Gateway for the connection of up to 32 INTERFACE system devices via Modbus/TCP to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR H3-IES-PT- 24DC/500AC-2 - Hybrid motor starter
2903916
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
EM-PNET-GATEWAY-IFS - Data interface
2904472
Gateway for the connection of up to 32 INTERFACE system devices via PROFINET to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
EM-PSAFE-GATEWAY-IFS - Data interface
1188207
Gateway for connecting up to 15 INTERFACE system devices to a higher-level secure controller via PROFIsafe. The system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H3-I-SC- 24DC/500AC-9 - Hybrid motor starter
2900545
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-IES-PT- 24DC/500AC-9 - Hybrid motor starter
2903918
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H5-I-PT- 24DC/500AC-9 - Hybrid motor starter
2903912
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT-24DC/500AC-2-T - Hybrid motor starter
2906059
Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 2.4 A; connection method: Push-in connection
ELR H5-SC- 24DC/500AC-9 - Hybrid motor starter
2900538
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, and screw connection.
ELR H3-I-PT- 24DC/500AC-9 - Hybrid motor starter
2903924
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-I-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903908
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
EM-PB-GATEWAY-IFS - Data interface
2297620
Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via PROFIBUS DP. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR W3-230AC/500AC- 9I - Hybrid motor starter
2297060
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection
ELR H5-IES-PT-24DC/500AC-9-T - Hybrid motor starter
2906060
Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 9 A; connection method: Push-in connection
ELR W3-230AC/500AC- 2I - Hybrid motor starter
2297044
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2 A output current, with 230 V AC control voltage, adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection
ELR H3-IES-PT/500AC-9-IOL - Hybrid motor starter
2908672
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IES-PT/500AC-9-IFS - Hybrid motor starter
2905140
Networkable hybrid motor starter for reversing of 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H3-IES-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900566
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
ELR H5-IS-SC- 24DC/500AC-3-P - Hybrid motor starter
2908699
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IS-PT- 24DC/500AC-3-P - Hybrid motor starter
2909570
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT-24DC/500AC-9-T - Hybrid motor starter
2906064
Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 9 A; connection method: Push-in connection
ELR H5-IS-PT- 24DC/500AC-9-P - Hybrid motor starter
2909567
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT/500AC-3-IOL - Hybrid motor starter
2908671
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-I-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900573
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H5-IES-SC/500AC-3-IFS - Hybrid motor starter
2905152
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection, DIN rail connector provided.
ELR H5-IES-SC/500AC-9-IFS - Hybrid motor starter
2905153
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection, DIN rail connector provided.
ELR H5-IES-SC-230AC/500AC-9 - Hybrid motor starter
2900422
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e
ELR H5-IES-PT- 24DC/500AC-3-P - Hybrid motor starter
2909556
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-SC/500AC-9-IFS - Hybrid motor starter
2905156
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 9 A, emergency stop function, adjustable overload shutdown, and screw connection, DIN rail connector provided.
ELR H3-SC- 24DC/500AC-9 - Hybrid motor starter
2900530
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage and screw connection.
ELR H5-IES-PT/500AC-3-IOL - Hybrid motor starter
2908669
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IS-SC- 24DC/500AC-9-P - Hybrid motor starter
2908697
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3 / PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903920
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903902
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-IES-SC/500AC-06-IFS - Hybrid motor starter
2905151
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3/PL e and screw connection, DIN rail connector provided.
ELR H5-I-SC-24DC/500AC-2-L - Hybrid motor starter
2905513
Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
ELR H3-IES-SC-230AC/500AC-9 - Hybrid motor starter
2900570
Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 9 A output current, emergency stop function, and adjustable overload shutdown.
ELR H5-IES-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900582
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR H3-IES-PT-24DC/500AC-06-T - Hybrid motor starter
2906061
Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 600 mA; connection method: Push-in connection
ELR H5-IES-PT/500AC-06-IFS - Hybrid motor starter
2905138
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H5-IES-PT-24DC/500AC-06-T - Hybrid motor starter
2906058
Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 600 mA; connection method: Push-in connection
ELR H5-IES-SC-230AC/500AC-2 - Hybrid motor starter
2900420
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 230 V AC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e
ELR H3-IES-SC-230AC/500AC-2 - Hybrid motor starter
2900568
Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown.
ELR H5-ES-SC- 24DC/500AC-2 - Hybrid motor starter
2900559
Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, and emergency stop function.
ELR H3-IES-PT/500AC-3-IFS - Hybrid motor starter
2905142
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
ELR H3-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903914
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H3-I-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900542
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-I-PT- 24DC/500AC-9-P - Hybrid motor starter
2909561
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-ES-SC- 24DC/500AC-9 - Hybrid motor starter
2900561
Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 9 A output current, and emergency stop function.
ELR H3-I-SC- 24DC/500AC-3-P - Hybrid motor starter
2908696
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
EM-ETH-GATEWAY-IFS - Data interface
2901988
Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via EtherNet/IP™. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR H5-I-SC- 24DC/500AC-3-P - Hybrid motor starter
2908695
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-IES-PT/500AC-9-IOL - Hybrid motor starter
2908670
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
EM-CAN-GATEWAY-IFS - Data interface
2901504
Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via CANopen®. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
ELR H3-IS-PT- 24DC/500AC-9-P - Hybrid motor starter
2909568
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT- 24DC/500AC-9-P - Hybrid motor starter
2909555
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT/500AC-9-IFS - Hybrid motor starter
2905143
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 9 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
ELR H3-IES-PT- 24DC/500AC-3-P - Hybrid motor starter
2909557
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H5-I-PT-24DC/500AC-2-L - Hybrid motor starter
1199926
Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
ELR H3-IES-PT-24DC/500AC-2-T - Hybrid motor starter
2906062
Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages; input: 24 V DC; output: 3~, 500 V AC, 2.4 A; connection method: Push-in connection
ELR H5-IES-PT- 24DC/500AC-9-P - Hybrid motor starter
2909554
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-PT- 24DC/500AC-3-P - Hybrid motor starter
2909563
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-9-P02 - Hybrid motor starter
1160740
Modular hybrid motor starter for starting and reversing motors incl. motor protection and rotary field monitoring, input: 24 V DC, output: 3~, 500 V AC, 9 A, connection method: Push-in connection
EM-2RSC/21AU-R/L-P - Extension module
2908701
Relay extension module for ELR-...-P hybrid motor starters, feedback of forward and reverse running when control signal is present, screw connection, DIN rail connector included
ELR H5-IS-PT- 24DC/500AC-3-P - Hybrid motor starter
2909569
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-9-P - Hybrid motor starter
2909560
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-SC- 24DC/500AC-9-P - Hybrid motor starter
2908693
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-3-P - Hybrid motor starter
2909562
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
EM-2RPT/21AU-R/L-P - Extension module
2909573
Relay extension module for ELR-...-P hybrid motor starters, feedback of forward and reverse running when control signal is present, Push-in connection, DIN rail connector included
ELR H3-IS-SC- 24DC/500AC-3-P - Hybrid motor starter
2908700
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-SC/500AC-3-IFS - Hybrid motor starter
2905155
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and screw connection, DIN rail connector provided.
ELR H3-IS-SC- 24DC/500AC-9-P - Hybrid motor starter
2908698
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-SC- 24DC/500AC-9-P - Hybrid motor starter
2908694
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR W1/ 6-24DC - Reversing load relay
2982090
Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 10 - 30 V DC/6 A with a switch-over time of 80 ms
ELR DCR-PT-24DC-10 - Reversing load relay
1291655
Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 24 V DC/10 A with a switch-over time of 100 ms
ELR DCR-PT-24DC-3 - Reversing load relay
1291615
Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 24 V DC/3 A with a switch-over time of 100 ms
PLC-SC-ELR W1/ 2-24DC - Reversing load relay
2980539
PLC-INTERFACE as an electronic reversing load relay, consisting of PLC-BSC.../21 basic terminal block with screw connection and integrated circuit, for driving DC motors, with LED and protective circuit, output: 10 ... 30 V DC/2 A
ELR W1/ 6-24DC/RDT - Reversing load relay
2982757
Electronic reversing load relay, for controlling DC motors, with LED display and protective circuit, output: 10 - 30 V DC/6 A with a switch-over time of 1 ms
PLC-PT-ELR W1/ 2-24DC - Reversing load relay
1069556
PLC-INTERFACE as an electronic reversing load relay, consisting of PLC-BPT.../21 basic terminal block with Push-in connection and integrated circuit, for driving DC motors, with LED display and protective circuit, output: 10 ... 30 V DC/2 A
ELR W1/ 2-24DC - Reversing load relay
2963598
Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit, output: 10-30 V DC/2 A
ELR W3/ 9-500 - Reversing load relay
2964186
Electronic reversing load relay, for direct driving of equipment in the 3-phase network, with light indicator and protection circuit, output: 110-550 V AC/3 x 9 A
ELR 1-SC-24DC/600AC-20 - Solid-state contactor
1032919
Single-phase solid-state contactor, input voltage: 24 V DC, output current: 20 A, zero voltage switch
ELR 1-SC-24DC/600AC-30 - Solid-state contactor
1032921
Single-phase solid-state contactor, input voltage: 24 V DC, output current: 30 A, zero voltage switch
ELR 1-SC-24DC/600AC-50 - Solid-state contactor
1032926
Single-phase solid-state contactor, input voltage: 24 V DC, output current: 50 A, zero voltage switch
ELR W2+1- 24DC/500AC-37 - Solid-state reversing contactor
2297374
Three-phase solid-state reversing contactor with 24 V DC input, 37 A output current, zero voltage switch, optionally with thermal fuse
ELR W3- 24DC/500AC- 9 - Solid-state reversing contactor
2297316
Three-phase solid-state reversing contactor with 24 V DC input, 9 A output current, zero voltage switch, optionally with thermal fuse
ELR W3- 24DC/500AC- 2 - Solid-state reversing contactor
2297293
Three-phase solid-state reversing contactor with 24 V DC input, 2 A output current, zero voltage switch, optionally with thermal fuse
ELR 1-SC-230AC/600AC-30 - Solid-state contactor
1032922
Single-phase solid-state contactor, input voltage: 230 V AC, output current: 30 A, zero voltage switch
ELR 1-SC-230AC/600AC-20 - Solid-state contactor
1032920
Single-phase solid-state contactor, input voltage: 230 V AC, output current: 20 A, zero voltage switch
ELR 1-SC-230AC/600AC-50 - Solid-state contactor
1032927
Single-phase solid-state contactor, input voltage: 230 V AC, output current: 50 A, zero voltage switch
CSS 0.55-3/3 - Speed starter
1201694
Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.55 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input
CSS 1.5-1/3-EMC - Speed starter
1201642
Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input, with integrated EMC filter
EM-CSS-SHIELDING-SET-SCC-35 - Shield connection
1451206
Accessories set for simple and reliable connection of cable shields to the CONTACTRON Speed Starter, consisting of a 35 mm shroud, 2 shield connection terminal blocks for the signal lines, and one shield connection terminal block for the motor cable.
CSS 1.5-3/3-EMC - Speed starter
1201696
Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input, with integrated EMC filter
CSS 1.5-3/3 - Speed starter
1201650
Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input
CSS 0.25-3/3-EMC - Speed starter
1201713
Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.25 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input, with integrated EMC filter
CSS 0.55-3/3-EMC - Speed starter
1201828
Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.55 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input, with integrated EMC filter
CSS 0.25-1/3 - Speed starter
1201132
Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 0.25 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input
EM-CSS-SHIELDING-SET-SCC-45 - Shield connection
1451208
Accessories set for simple and reliable connection of cable shields to the CONTACTRON Speed Starter, consisting of a 45 mm shroud, 2 shield connection terminal blocks for the signal lines, and one shield connection terminal block for the motor cable.
CSS 0.75-3/3 - Speed starter
1201695
Speed starter with soft start and configurable speed for starting and reversing motors up to 480 V AC and 0.75 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, three-phase load input
CSS 0.37-1/3 - Speed starter
1201135
Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 0.37 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input
CSS 1.5-1/3 - Speed starter
1201511
Speed starter with soft start and configurable speed for starting and reversing motors up to 230 V AC and 1.5 kW, configurable motor protection, analog input, STO function up to SIL 3/PL e, single-phase load input
CSS 0.75-3/3-EMC - Speed starter
1201829
Speed starter with soft start and co