Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414 là Khởi động động cơ 3AC-500V 2.4A 24VDC SIL3-PL
- Tài liệu kỹ thuật Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414 ở đây.
Technical data của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Product properties của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Product type |
Hybrid motor starters |
Product family |
CONTACTRON |
Operating mode |
100% operating factor |
Electrical properties của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Number of phases |
3 |
Motor starter type |
Reversing starter |
Switching frequency |
≤ 2 Hz (Load-dependent) |
Maximum power dissipation for nominal condition |
2.2 W |
Switching frequency |
≤ 2 Hz (Load-dependent) |
Maximum power dissipation |
3.3 W |
Minimum power dissipation |
1.1 W |
Coordination type |
1 |
Supply |
Rated control circuit supply voltage US |
24 V DC |
Control supply voltage range |
19.2 V DC ... 30 V DC |
Rated control supply current IS |
40 mA |
Protective circuit |
Surge protection |
Reverse polarity protection |
Insulation characteristics |
Rated insulation voltage |
500 V |
Rated surge voltage |
6 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC |
Basic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC |
Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Input data của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Control |
Input name |
Control input right/left |
Rated actuating voltage UC |
24 V DC |
Triggering voltage range |
19.2 V DC ... 30 V DC |
Rated actuating current IC |
5 mA (Input type 1) |
Switching threshold |
9.6 V (“0” signal) |
19.2 V (“1” signal) |
Switching level |
< 5 V DC (For EMERGENCY STOP) |
Typical turn-off time |
< 30 ms |
Protective circuit |
Reverse polarity protection |
Output data của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
AC output |
Rated operating voltage Ue |
500 V AC |
Operating voltage range |
42 V AC ... 550 V AC |
Rated operating current Ie |
2.4 A (AC-51) |
2.4 A (AC-53a) |
Mains frequency |
50/60 Hz |
Load current range |
180 mA ... 2.4 A (see to derating) |
Trigger characteristic in acc. with IEC 60947-4-2 |
Class 10A |
Cooling time |
20 min (for auto reset) |
Leakage current |
0 mA |
Protective circuit |
Surge protection |
Acknowledge output |
Note |
Confirmation: floating change-over contact, signal contact |
Contact switching type |
1 changeover contact |
Switching capacity in accordance with IEC 60947-5-1 |
3 A (230 V, AC15) |
2 A (24 V (DC13)) |
Connection data của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Control circuits |
Connection method |
Screw connection |
Stripping length |
8 mm |
Screw thread |
M3 |
Conductor cross section rigid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Tightening torque |
0.5 Nm ... 0.6 Nm |
5 lbf-in. ... 7 lbf-in. |
Load circuit |
Connection method |
Screw connection |
Stripping length |
8 mm |
Screw thread |
M3 |
Conductor cross section rigid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Tightening torque |
0.5 Nm ... 0.6 Nm |
5 lbf-in. ... 7 lbf-in. |
Signaling của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Status display |
LED (yellow) |
Operating voltage display |
Green LED |
Error indication |
Red LED |
Dimensions của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Width |
22.5 mm |
Height |
107 mm |
Depth |
114 mm |
Material specifications của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Flammability rating according to UL 94 |
V0 (Housing) |
Environmental and real-life conditions của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Ambient conditions |
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C ... 70 °C (observe derating) |
Ambient temperature (storage/transport) |
-40 °C ... 80 °C |
Altitude |
≤ 2000 m |
Approvals của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
UKCA |
Certificate |
UKCA-compliant |
ATEX |
Identification |
II (2) G [Ex e] [Ex d] [Ex px] |
II (2) D [Ex t] [Ex p] |
Certificate |
PTB 07 ATEX 3145 |
UL approval |
Certificate |
NLDX.E228652 |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
≤ 3 |
Note |
Safe shutdown |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
2 |
Note |
Motor protection |
Performance Level (ISO 13849) |
Identification |
≤ e |
Note |
Safe shutdown |
Category (ISO 13849) |
Identification |
≤ 3 |
Note |
Safe shutdown |
UL data |
SCCR |
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) |
FLA |
2.4 A (500 V AC) |
Group installation |
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) |
Category code |
NLDX |
Standards and regulations của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Standards/regulations |
Standards/regulations |
IEC 60947-1 |
IEC 60947-4-2 |
IEC 61508 |
ISO 13849 |
Mounting của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Mounting type |
DIN rail mounting |
Assembly note |
alignable, for spacing see derating |
Mounting position |
vertical (horizontal DIN rail, motor output below) |
Commercial data của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
Item number |
2900414 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Product key |
DK7412 |
Catalog page |
Page 28 (C-5-2019) |
GTIN |
4046356504058 |
Weight per piece (including packing) |
323.1 g |
Weight per piece (excluding packing) |
269.6 g |
Customs tariff number |
85371098 |
Country of origin |
DE |
Classifications của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
ECLASS
ECLASS-12.0 |
27370905 |
ECLASS-13.0 |
27370905 |
ETIM
UNSPSC
Approvals của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
IECEE CB Scheme
Approval ID: DE1-55728
EAC
Approval ID: RU*C-DE.*08.B.00520*
DNV GL
Approval ID: TAA00002HK
UL Listed
Approval ID: FILE E 323771
CCC
Approval ID: 2016010304871315
cUL Listed
Approval ID: FILE E 323771
cUL Listed
Approval ID: E228652
UL Listed
Approval ID: E228652
ATEX
Approval ID: PTB 07 ATEX 3145
Environmental product compliance của Khởi động động cơ Phoenix Contact ELR H5-IES-SC- 24DC/500AC-2 - 2900414
EU RoHS |
Fulfills EU RoHS substance requirements |
Yes |
Exemption |
7(a), 7(c)-I |
China RoHS |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
EU REACH SVHC |
REACH candidate substance (CAS No.) |
Lead (CAS: 7439-92-1) |
SCIP |
da3d2eb7-11ad-4a29-b238-1d9ed791a85f |
Tham khảo thêm các model khác cùng loại với :
Bộ khởi động động cơ hybrid
Bộ khởi động động cơ lai (hybrid) của Phoenix Contact thay thế contactor đảo chiều thông thường và bảo vệ động cơ bằng một thiết bị duy nhất. Chuyển đổi động cơ một cách an toàn và đáng tin cậy bằng bộ khởi động động cơ lai. Sử dụng các thiết bị ở bất cứ nơi nào cần đảo chiều và bảo vệ động cơ không đồng bộ ba pha. Dòng sản phẩm bộ khởi động động cơ lai bao gồm bộ khởi động trực tiếp và đảo chiều, có nhiều chức năng khác nhau như dừng khẩn cấp.
ELR W3- 24DC/500AC- 2I - Hybrid motor starter
2297031
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection
ELR H5-IES-SC- 24DC/500AC-2 - Hybrid motor starter
2900414
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3 / PL e and screw connection
ELR H5-I-SC- 24DC/500AC-2 - Hybrid motor starter
2900574
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-I-SC- 24DC/500AC-2 - Hybrid motor starter
2900543
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR W3- 24DC/500AC- 9I - Hybrid motor starter
2297057
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR H3-IES-SC- 24DC/500AC-2 - Hybrid motor starter
2900567
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and, screw connection.
ELR H5-IES-SC- 24DC/500AC-9 - Hybrid motor starter
2900421
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR W3-230AC/500AC- 2I - Hybrid motor starter
2297044
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2 A output current, with 230 V AC control voltage, adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection
ELR H5-IES-PT- 24DC/500AC-9 - Hybrid motor starter
2903906
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-I-PT- 24DC/500AC-2 - Hybrid motor starter
2903910
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter
2905139
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR W3-230AC/500AC- 9I - Hybrid motor starter
2297060
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and screw connection
ELR H5-IES-PT- 24DC/500AC-2 - Hybrid motor starter
2903904
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
EM-PSAFE-GATEWAY-IFS - Data interface
1188207
Gateway for the connection of up to 15 Interface system devices to a higher-level safe controller via PROFIsafe. The system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H3-IES-SC- 24DC/500AC-9 - Hybrid motor starter
2900569
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
ELR H5-ES-SC- 24DC/500AC-2 - Hybrid motor starter
2900559
Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, and emergency stop function.
ELR H5-I-SC- 24DC/500AC-9 - Hybrid motor starter
2900576
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H3-I-PT- 24DC/500AC-2 - Hybrid motor starter
2903922
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H3-IES-PT- 24DC/500AC-2 - Hybrid motor starter
2903916
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H5-IES-PT-24DC/500AC-2-T - Hybrid motor starter
2906059
Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages, ATEX; input: 24 V DC; output: 3~, 500 V AC, 2.4 A; Push-in connection
ELR H3-I-SC- 24DC/500AC-9 - Hybrid motor starter
2900545
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H5-SC- 24DC/500AC-9 - Hybrid motor starter
2900538
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, and screw connection.
EM-PNET-GATEWAY-IFS - Data interface
2904472
Gateway for the connection of up to 32 Interface system devices to a higher-level controller via PROFINET. The Interface system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H3-I-PT- 24DC/500AC-9 - Hybrid motor starter
2903924
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H3-IES-PT- 24DC/500AC-9 - Hybrid motor starter
2903918
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H51-IESSC-24DC500AC-9 - Hybrid motor starter
2902745
Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 9 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD adapter, EM-RI adapter or power distribution board.
ELR H5-I-PT- 24DC/500AC-9 - Hybrid motor starter
2903912
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
EM-MODBUS-GATEWAY-IFS - Data interface
2901528
Gateway for the connection of up to 32 Interface system devices to a higher-level controller via Modbus/TCP. The Interface system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H3-IES-PT/500AC-3-IOL - Hybrid motor starter
2908671
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IES-PT-24DC/500AC-9-T - Hybrid motor starter
2906060
Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages, ATEX; input: 24 V DC; output: 3~, 500 V AC, 9 A; Push-in connection
ELR H5-IES-PT/500AC-9-IFS - Hybrid motor starter
2905140
Networkable hybrid motor starter for reversing of 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H3-IES-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900566
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
ELR H3-IES-SC-230AC/500AC-9 - Hybrid motor starter
2900570
Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 9 A output current, emergency stop function, and adjustable overload shutdown.
ELR H3-IS-PT- 24DC/500AC-3-P - Hybrid motor starter
2909570
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT-24DC/500AC-9-T - Hybrid motor starter
2906064
Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages, ATEX; input: 24 V DC; output: 3~, 500 V AC, 9 A; Push-in connection
ELR H5-I-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900573
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H5-IES-SC-230AC/500AC-9 - Hybrid motor starter
2900422
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 230 V AC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e
ELR H3-SC- 24DC/500AC-9 - Hybrid motor starter
2900530
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage and screw connection.
ELR H3-IES-PT-24DC/500AC-06-T - Hybrid motor starter
2906061
Hybrid motor starter; functions: Start motor, Motor protection: (class 10A), Emergency stop to SIL 3/PL e, Underload detection, Higher resistance to transient voltages, ATEX; input: 24 V DC; output: 3~, 500 V AC, 600 mA; Push-in connection
ELR H5-IES-PT/500AC-06-IFS - Hybrid motor starter
2905138
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
ELR H51-IESSC-24DC500AC-2 - Hybrid motor starter
2902744
Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board.
ELR H5-ES-SC- 24DC/500AC-9 - Hybrid motor starter
2900561
Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 9 A output current, and emergency stop function.
ELR H5-IES-PT-24DC/500AC-06-T - Hybrid motor starter
2906058
Hybrid motor starter; functions: Start motor, Reverse motor, Motor protection, Emergency stop, Higher resistance to transient voltages, ATEX; input: 24 V DC; output: 3~, 500 V AC, 600 mA; Push-in connection
EM-ETH-GATEWAY-IFS - Data interface
2901988
Gateway for the connection of up to 32 Interface system devices to a higher-level controller via EtherNet/IP™. The Interface system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H5-IES-PT/500AC-9-IOL - Hybrid motor starter
2908670
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IES-SC-230AC/500AC-2 - Hybrid motor starter
2900420
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 2.4 A output current, with 230 V AC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e
ELR H5-IS-PT- 24DC/500AC-9-P - Hybrid motor starter
2909567
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H5-IES-PT- 24DC/500AC-3-P - Hybrid motor starter
2909556
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT/500AC-9-IOL - Hybrid motor starter
2908672
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-IES-PT/500AC-3-IOL - Hybrid motor starter
2908669
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
ELR H5-I-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903908
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
ELR H5-IS-PT- 24DC/500AC-3-P - Hybrid motor starter
2909569
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-I-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903920
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.
EM-PB-GATEWAY-IFS - Data interface
2297620
Gateway for the connection of up to 32 Interface system devices to a higher-level controller via PROFIBUS DP. The Interface system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H5-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903902
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
ELR H5-I-SC-24DC/500AC-2-L - Hybrid motor starter
2905513
Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
ELR H5-IES-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900582
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.
ELR H3-IES-SC-230AC/500AC-2 - Hybrid motor starter
2900568
Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown.
ELR H3-IES-PT/500AC-3-IFS - Hybrid motor starter
2905142
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
ELR H3-IES-PT- 24DC/500AC-0,6 - Hybrid motor starter
2903914
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
ELR H3-I-SC- 24DC/500AC-0,6 - Hybrid motor starter
2900542
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and screw connection.
ELR H51-IES-24DC500AC-9-IFS - Hybrid motor starter
1151587
Hybrid motor starter; functions: start motor, reverse motor, motor protection, emergency stop, network capable, short-circuit protection; input: 24 V DC; output: 3~, 500 V AC, 9 A; connection method: screw and Push-in connection; connection to the Interface system
ELR H3-I-PT- 24DC/500AC-9-P - Hybrid motor starter
2909561
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
EM-CAN-GATEWAY-IFS - Data interface
2901504
Gateway for the connection of up to 32 Interface system devices to a higher-level controller via CANopen®. The Interface system devices are connected to the gateway via DIN rail connectors. The DIN rail connectors are provided.
ELR H3-IS-PT- 24DC/500AC-9-P - Hybrid motor starter
2909568
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection and emergency stop up to SIL 3/PL e. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H3-IES-PT- 24DC/500AC-9-P - Hybrid motor starter
2909555
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H51-IES-24DC500AC-9-IOL - Hybrid motor starter
1151610
Hybrid motor starter; functions: start motor, reverse motor, motor protection, emergency stop, network capable, short-circuit protection; input: 24 V DC; output: 3~, 500 V AC, 9 A; connection method: screw and Push-in connection; connection to the IO-Link system
ELR H3-IES-PT/500AC-9-IFS - Hybrid motor starter
2905143
Networkable hybrid motor starter for starting 3~ AC motors up to 500 V AC, output current: 9 A, emergency stop function, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
ELR H3-IES-PT- 24DC/500AC-3-P - Hybrid motor starter
2909557
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H5-I-PT-24DC/500AC-2-L - Hybrid motor starter
1199926
Hybrid motor starter, for reversing 3~ AC motors up to 550 V AC/2.4 A, 24 V DC input, class 10 tripping characteristic, overload function, without symmetry monitoring, and without phase failure and underload detection. 1-phase motors can be switched.
ELR H3-IES-PT-24DC/500AC-2-T - Hybrid motor starter
2906062
Hybrid motor starter; functions: Start motor, Motor protection, Emergency stop, Higher resistance to transient voltages, ATEX; input: 24 V DC; output: 3~, 500 V AC, 2.4 A; Push-in connection
ELR H5-IES-PT- 24DC/500AC-9-P - Hybrid motor starter
2909554
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, provides motor protection, ATEX, and emergency stop up to SIL 3. Group shut-down, supply, and relay extension possible via DIN rail connector.
ELR H51-IES-24DC500AC-3-IOL - Hybrid motor starter
1151617
Hybrid motor starter; functions: start motor, reverse motor, motor protection, emergency stop, network capable, short-circuit protection; input: 24 V DC; output: 3~, 500 V AC, 3 A; connection method: screw and Push-in connection; connection to the IO-Link system
ELR H3-I-PT- 24DC/500AC-3-P - Hybrid motor starter
2909563
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H51-IES-24DC500AC-3-IFS - Hybrid motor starter
1151618
Hybrid motor starter; functions: start motor, reverse motor, motor protection, emergency stop, network capable, short-circuit protection; input: 24 V DC; output: 3~, 500 V AC, 3 A; connection method: screw and Push-in connection; connection to the Interface system
ELR H5-I-PT- 24DC/500AC-9-P02 - Hybrid motor starter
1160740
Modular hybrid motor starter for starting and reversing motors incl. motor protection and rotary field monitoring, input: 24 V DC, output: 3~, 500 V AC, 9 A, connection method: Push-in connection
ELR H5-I-PT- 24DC/500AC-9-P - Hybrid motor starter
2909560
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
ELR H5-I-PT- 24DC/500AC-3-P - Hybrid motor starter
2909562
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
EM-2RPT/21AU-R/L-P - Extension module
2909573
Relay extension module for ELR-...-P hybrid motor starters, feedback of forward and reverse running when control signal is present, Push-in connection, DIN rail connector included
ELR H51-IESSC-24DC500AC-06 - Hybrid motor starter
2902746
Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 0.6 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board.