Bộ khởi động động cơ lai Phoenix Contact ELR H5-IES-SC- 24DC/500AC-9 - 2900421 | Hybrid motor starter
(đảo chiều 3AC 500VAC 9A 24VDC SIL 3/PL e)
Drawings
Block diagram
Diagram
Derating diagram
Circuit diagram
Conventional structure
Main current path for reversing contactor according to category 3
K1 + K2 = Emergency stop contactor
K3 = Left contactor
K4 = Right contactor
F4 = Motor protection relay
Circuit diagram
Conventional structure
Control current path reversing contactor according to category 3
K1 + K2 = Emergency stop contactor
K3 = Left contactor
K4 = Right contactor
K5 = PSR SCP-24DC.../Safety relay
T1 = Right, T2 = Left, T3 = Reset
S2 = Emergency stop
F4 = Motor protection relay
Circuit diagram
Structure with CONTACTRON
Main and control current path for ,4 in 1, hybrid motor starter with reversing function according to category 3
K1 = ,4 in 1, hybrid motor starter with reversing function
K5 = PSR SCP-24DC.../Safety relay
T1 = Right, T2 = Left, T3 = Reset
S2 = Emergency stop
Dimensions
Width |
22.5 mm |
Height |
107 mm |
Depth |
114 mm |
Ambient conditions
Ambient temperature (operation) |
-25 °C ... 70 °C (observe derating) |
Ambient temperature (storage/transport) |
-40 °C ... 80 °C |
Maximum altitude |
≤ 2000 m |
Degree of protection |
IP20 |
Device supply
Rated control circuit supply voltage US |
24 V DC |
Control supply voltage range |
19.2 V DC ... 30 V DC |
Rated control supply current IS |
40 mA |
Type of protection |
Surge protection |
|
Reverse polarity protection |
Input data
Input name |
Control input right/left |
Rated actuating voltage UC |
24 V DC |
Triggering voltage range |
19.2 V DC ... 30 V DC |
Rated actuating current IC |
5 mA (Input type 1) |
Switching threshold |
9.6 V (“0” signal) |
|
19.2 V (“1” signal) |
Switching level |
< 5 V DC (For EMERGENCY STOP) |
Typical turn-off time |
< 30 ms |
Type of protection |
Reverse polarity protection |
Output data load output
Output name |
AC output |
Rated operating voltage Ue |
500 V AC |
Operating voltage range |
42 V AC ... 550 V AC |
Rated operating current Ie |
9 A (AC-51) |
|
6.5 A (AC-53a) |
Mains frequency |
50/60 Hz |
Load current range |
1.5 A ... 9 A (see to derating) |
Trigger characteristic in acc. with IEC 60947-4-2 |
Class 10A |
Cooling time |
20 min. (for auto reset) |
Leakage current |
0 mA |
Type of protection |
Surge protection |
Output data reply output
Output name |
Acknowledge output |
Note |
Confirmation: floating change-over contact, signal contact |
Contact type |
1 changeover contact |
Switching capacity according to IEC 60947-5-1 |
3 A (230 V, AC15) |
|
2 A (24 V, DC13) |
Overspeed tripping
Operate threshold |
> 45 A |
Response time |
< 2 s |
General
Motor starter type |
Reversing starter |
Switching frequency |
≤ 2 Hz (Load-dependent) |
Mounting position |
vertical (horizontal DIN rail, motor output below) |
Mounting type |
DIN rail mounting |
Assembly instructions |
alignable, for spacing see derating |
Operating mode |
100% operating factor |
Maximum power dissipation |
14.6 W |
Minimum power dissipation |
1.1 W |
Operating voltage display |
Green LED |
Status display |
Yellow LED |
Indication |
Red LED |
Connection data
Connection name |
Control circuits |
Connection method |
Screw connection |
Stripping length |
8 mm |
Screw thread |
M3 |
Conductor cross section solid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Torque |
0.5 Nm ... 0.6 Nm |
|
5 lbf-in. ... 7 lbf-in. |
Connection data 2
Connection name |
Load circuit |
Connection method |
Screw connection |
Stripping length |
8 mm |
Screw thread |
M3 |
Conductor cross section solid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
24 ... 14 |
Torque |
0.5 Nm ... 0.6 Nm |
|
5 lbf-in. ... 7 lbf-in. |
Insulation characteristics
Rated insulation voltage |
500 V |
Rated surge voltage |
6 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Designation |
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
Insulation |
Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC |
|
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC |
|
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC |
Designation |
Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
Insulation |
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
|
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
Standards and Regulations
Designation |
Standards/regulations |
Standards/regulations |
IEC 60947-1 |
|
IEC 60947-4-2 |
|
IEC 61508 |
|
ISO 13849 |
Conformance/approvals
Designation |
ATEX |
Identification |
II (2) G [Ex e] [Ex d] [Ex px] |
|
II (2) D [Ex t] [Ex p] |
Certificate |
PTB 07 ATEX 3145 |
Designation |
UL approval |
Certificate |
NLDX.E228652 |
Designation |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
≤ 3 |
Additional text |
Safe shutdown |
Designation |
Safety Integrity Level (SIL, IEC 61508) |
Identification |
2 |
Additional text |
Motor protection |
Designation |
Performance Level (ISO 13849) |
Identification |
≤ e |
Additional text |
Safe shutdown |
Designation |
Category (ISO 13849) |
Identification |
≤ 3 |
Additional text |
Safe shutdown |
UL data
SCCR |
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
|
5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) |
FLA |
6.5 A (500 V AC) |
Group installation |
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
|
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) |
Category code |
NLDX |
Environmental Product Compliance
REACh SVHC |
Lead 7439-92-1 |
China RoHS |
Environmentally Friendly Use Period = 50 years |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
ECLASS
ECLASS 10.0.1 |
27370905 |
ECLASS 11.0 |
27370905 |
ECLASS 4.0 |
27021100 |
ECLASS 4.1 |
27021100 |
ECLASS 5.0 |
27024000 |
ECLASS 5.1 |
27024000 |
ECLASS 6.0 |
27024000 |
ECLASS 7.0 |
27024002 |
ECLASS 9.0 |
27370905 |
ETIM
ETIM 2.0 |
EC001037 |
ETIM 3.0 |
EC001037 |
ETIM 4.0 |
EC001037 |
ETIM 6.0 |
EC001037 |
ETIM 7.0 |
EC001037 |
UNSPSC
UNSPSC 6.01 |
30211915 |
UNSPSC 7.0901 |
39121514 |
UNSPSC 11 |
39121514 |
UNSPSC 12.01 |
39121514 |
UNSPSC 13.2 |
25173902 |
UNSPSC 18.0 |
25173902 |
UNSPSC 19.0 |
25173902 |
UNSPSC 20.0 |
25173902 |
UNSPSC 21.0 |
25173902 |