Phoenix Contact UNO-DIODE/5-24DC/2X10/1X20 - 2905489 Redundancy module - Bộ chuyển nguồn dự phòng 5-24VDC 2x10A 1x20A

Phoenix Contact UNO-DIODE/5-24DC/2X10/1X20 - 2905489 Redundancy module - Bộ chuyển nguồn dự phòng 5-24VDC 2x10A 1x20A

1,321
Nhà sản xuất:

Phoenix Contact

;   

Xuất xứ: Germany

Giá sỉ:

Giá tốt nhất xem...0909186879 dienelectrics@gmail.com

Khuyến mãi:Có Discount
Bảo hành:12 Tháng (Chính hãng)
Thanh toán:C.O.D / Bảo lãnh TT / Link hoạt
Vận chuyển:Miễn phí Tp.HCM, vùng lân cận
Thông tin nổi bật

Chi tiết thông tin đặc tính sản phẩm

Phoenix Contact UNO-DIODE/5-24DC/2X10/1X20 - 2905489 Redundancy module - Bộ chuyển nguồn dự phòng 5-24VDC 2x10A 1x20A

 

Product Description

A safe redundant system is the result of the parallel connection of two power supply units which are decoupled from one another. To further increase system availability, UNO DIODE provides the solution: decoupling with diode.

 

Your advantages

- Flexible mounting by simply snapping onto the DIN rail
- Save energy
- Rugged design
- Permanent monitoring of redundancy
- Consistent redundancy up to the load

 

Bản vẽ kỹ thuật


Block diagram


 

Dimensions

Width 22.5 mm
Height 90 mm
Depth 84 mm
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 30 mm / 30 mm


 

Ambient conditions

Degree of protection IP20
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2


 

Input data

Nominal input voltage range 5 V DC ... 24 V DC
Input voltage range 4.5 V DC ... 30 V DC
Nominal input current 2x 10 A (-25 °C ... 55 °C)
  1x 20 A (-25 °C ... 55 °C)


 

Output data

Nominal output current (IN) 20 A
Derating 55 °C ... 70 °C (2.5%/K)
Connection in series No
Power loss nominal load max. 5 W (IOUT = 10 A)


 

General

Net weight 0.2 kg
Efficiency > 97 %
MTBF (IEC 61709, SN 29500)  
  > 60600000 h (40 °C)
   
Insulation voltage input/output 1 kV AC (type test)
  0.5 kV AC (routine test)
Degree of protection IP20
Protection class III
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Housing material Polycarbonate
Foot latch material POM (Polyoxymethylen)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: 0 mm horizontally, 30 mm vertically


 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 8 mm
Screw thread M3


 

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 8 mm
Screw thread M3


 

Standards

Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)


 

Conformance/approvals

UL approvals UL/C-UL listed UL 508
  UL/C-UL Recognized UL 60950-1


 

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 4 kV (Test Level 3)
Discharge in air 8 kV (Test Level 3)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m
Frequency range 2 GHz ... 3 GHz
Test field strength 10 V/m
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Comments Criterion B
Surge voltage load (surge) EN 61000-4-5
Input 1 kV (Test Level 3 - symmetrical)
  2 kV (Test Level 4 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
  2 kV (Test Level 3 - asymmetrical)
Comments Criterion B
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Voltage dips EN 61000-4-11
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.


 

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


 

Classifications

eCl@ss

eCl@ss 10.0.1 27371010
eCl@ss 5.0 27371000
eCl@ss 5.1 27371000
eCl@ss 6.0 27371000
eCl@ss 7.0 27371010
eCl@ss 8.0 27371010
eCl@ss 9.0 27371010


 

ETIM

ETIM 4.0 EC002540
ETIM 5.0 EC002540
ETIM 6.0 EC002540
ETIM 7.0 EC002540


 

UNSPSC

UNSPSC 13.2 39121004
UNSPSC 18.0 32151504
UNSPSC 19.0 32151504
UNSPSC 20.0 32151504
UNSPSC 21.0 32151504
 

- Xem chi tiết Tài liệu kỹ thuật, Hướng dẫn sử dụng/ Datasheet, Manual, Catalogue Redundancy module UNO-DIODE/5-24DC/2X10/1X20 - 2905489 Phoenix Contact


Sản phẩm cùng loại
Gọi điện thoại