Phoenix Contact MINI MCR-SL-I-I - 2864406 Signal conditioner - Bộ khuếch đại cách ly tín hiệu Analog (0)4-20mA
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0(4) mA ... 20 mA, output signal: 0(4) mA ... 20 mA
Product Description
- The 6.2 mm wide MINI MCR-SL-RPS-I-I... repeater power supply supplies transmitters in the field and electrically isolates the input signal from the output signal. The module can be used in both isolator and repeater power supply operation.
- Electrically isolated 0...20 mA or 4...20 mA analog standard signals are available on the input and output side.
- The power supply (19.2 V DC to 30 V DC) can be supplied via connection terminal blocks on the modules or in conjunction with the DIN rail connector.
Your advantages
- Power supply possible via the foot element (TBUS)
- Can be used as an isolator with passive input
- Highly-compact repeater power supplies for electrical isolation, amplification, and filtering of standard analog signals
- 3-way isolation
- Supply of 2-wire and passive 3-wire sensors
Bản vẽ kỹ thuật
Block diagram
Dimensional drawing
Note
Utilization restriction |
EMC: class A product, see manufacturer's declaration in the download area |
Dimensions
Width |
6.2 mm |
Height |
93.1 mm |
Depth |
101.2 mm |
Ambient conditions
Ambient temperature (operation) |
-20 °C ... 65 °C |
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
Degree of protection |
IP20 |
Noise immunity |
EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Input data
Number of inputs |
1 |
Configurable/programmable |
no |
Current input signal |
0 mA ... 20 mA |
|
4 mA ... 20 mA |
Max. input current |
50 mA |
Input resistance current input |
approx. 50 Ω |
Output data
Number of outputs |
1 |
Configurable/programmable |
no |
Current output signal |
0 mA ... 20 mA |
|
4 mA ... 20 mA |
Max. output current |
28 mA |
Load/output load current output |
< 500 Ω (at 20 mA) |
Ripple |
< 20 mVPP (at 500 Ω) |
Power supply
Nominal supply voltage |
24 V DC |
Supply voltage range |
19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
Max. current consumption |
< 20 mA |
Power consumption |
< 450 mW |
Connection data
Connection method |
Screw connection |
Stripping length |
12 mm |
Screw thread |
M3 |
Conductor cross section solid |
0.2 mm² ... 2.5 mm² |
Conductor cross section flexible |
0.2 mm² ... 2.5 mm² |
Conductor cross section AWG |
26 ... 12 |
General
No. of channels |
1 |
Maximum transmission error |
≤ 0.1 % (of final value) |
Maximum temperature coefficient |
< 0.01 %/K |
Temperature coefficient, typical |
< 0.002 %/K |
Limit frequency (3 dB) |
approx. 100 Hz |
Step response (10-90%) |
approx. 3.2 ms |
Protective circuit |
Transient protection |
Electrical isolation |
Basic insulation according to EN 61010 |
Overvoltage category |
II |
Degree of pollution |
2 |
Rated insulation voltage |
50 V AC/DC |
Test voltage, input/output/supply |
1.5 kV (50 Hz, 1 min.) |
Electromagnetic compatibility |
Conformance with EMC directive |
Noise emission |
EN 61000-6-4 |
Noise immunity |
EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Color |
green |
Housing material |
PBT |
Mounting position |
any |
Assembly instructions |
The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
Fire protection for rail vehicles (DIN EN 45545-2) R22 |
HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 |
HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 |
HL 1 - HL 2 |
EMC data
Designation |
Electromagnetic RF field |
Standards/regulations |
EN 61000-4-3 |
Typical deviation from the measuring range final value |
10 % |
Designation |
Fast transients (burst) |
Standards/regulations |
EN 61000-4-4 |
Typical deviation from the measuring range final value |
10 % |
Designation |
Conducted interferences |
Standards/regulations |
EN 61000-4-6 |
Typical deviation from the measuring range final value |
10 % |
Standards and Regulations
Electromagnetic compatibility |
Conformance with EMC directive |
Noise emission |
EN 61000-6-4 |
Connection in acc. with standard |
CUL |
Designation |
Electromagnetic RF field |
Standards/regulations |
EN 61000-4-3 |
|
EN 61000-4-4 |
Designation |
Conducted interferences |
Standards/regulations |
EN 61000-4-6 |
Electrical isolation |
Basic insulation according to EN 61010 |
Conformance |
CE-compliant |
ATEX |
II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada |
UL 508 Recognized |
|
Class I, Div. 2, Groups A, B, C, D T5 |
GL |
GL EMC 2 D |
Conformance/approvals
Designation |
CE |
Identification |
CE-compliant |
Designation |
ATEX |
Identification |
II 3 G Ex nA IIC T4 Gc X |
Designation |
UL, USA/Canada |
Identification |
UL 508 Recognized |
|
Class I, Div. 2, Groups A, B, C, D T5 |
Designation |
GL |
Identification |
GL EMC 2 D |
Environmental Product Compliance
REACh SVHC |
Lead 7439-92-1 |
China RoHS |
Environmentally Friendly Use Period = 50 years |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
eCl@ss 4.0 |
27210100 |
eCl@ss 4.1 |
27210100 |
eCl@ss 5.0 |
27210100 |
eCl@ss 5.1 |
27210100 |
eCl@ss 6.0 |
27210100 |
eCl@ss 7.0 |
27210120 |
eCl@ss 8.0 |
27210120 |
eCl@ss 9.0 |
27210120 |
ETIM
ETIM 4.0 |
EC002653 |
ETIM 5.0 |
EC002653 |
ETIM 6.0 |
EC002653 |
ETIM 7.0 |
EC002653 |
UNSPSC
UNSPSC 6.01 |
30211506 |
UNSPSC 7.0901 |
39121008 |
UNSPSC 11 |
39121008 |
UNSPSC 12.01 |
39121008 |
UNSPSC 13.2 |
39121008 |
UNSPSC 18.0 |
39121008 |
UNSPSC 19.0 |
39121008 |
UNSPSC 20.0 |
39121008 |
UNSPSC 21.0 |
39121008 |