Chi tiết thông tin đặc tính sản phẩm
Protector trip relay - Crompton Instruments - 250 Series - Phase Sequence and Phase Failure
Features
- Three-phase, three or four-wire
- LED trip indication
- Double-pole relay contacts
- Automatic reset
Benefits
- Monitoring of correct phase rotation
- Protection against incorrect phase sequence and loss of phase
- Under-voltage monitoring
- Prevents reverse rotation of motor driven equipment
- Ensures correct engine rotation
- Protects portable electrical equipment
Applications
- Marine panels
- Switchgear
- Distribution systems
- Generator sets
- Control panels
- Process control
- Motor protection
- Transformers
- Overload protection
Operation
Rotating machines are particularly vulnerable to incorrect phase sequence. Three-phase motors can rotate in the wrong direction, potentially leading to physical damage or the risk of injury to personnel, yet voltage and current readings may appear normal. If one phase is lost because of a blown fuse, electric motors can continue to operate (single-phasing) which can result in severe electrical or
mechanical damage. For permanent installations, this relay should be used to monitor the incoming supply, protecting all equipment against incorrect connection at initial installation or after maintenance work. Rotating machines that cannot tolerate reverse rotation or pose significant risk to personnel under this condition should be individually protected with this relay. The possibility of incorrect supply
connection is much more likely in portable equipment or marine applications.
The phase sequence and phase failure protectors continuously monitor the three-phase supply. With the correct phase sequence applied, the front panel LED will illuminate and the output relay will be energised. An incorrect sequence or missing phase will de-energise the relay and the LED will be extinguished. If the supply drops below 85% of its nominal voltage, this condition will also cause a trip.
Note: If one phase is lost due to a blown fuse, some loads can re-generate the missing voltage. This relay can be used as a phase failure relay providing the regenerated voltage in the open phase is less than 70% of the nominal supply voltage. If there is the possibility of a higher regenerated voltage, the phase balance relay 252-PSF should be used.
Product Codes
Relay |
Protection |
ANSI no. |
Cat. no. |
3-phase 3- or 4-wire |
Phase sequence, under-voltage 85% |
47 |
252-PVR |
Please specify system voltage, frequency and required options at time of ordering.
Specification – Phase Sequence and Phase Failure
Nominal voltage |
110V, 120V, 208V, 220V, 230V, 240V, 277V, 380V, 400V, 415V, 440V or 480V |
Nominal frequency |
50, 60 or 400Hz |
Voltage burden |
3VA approx. |
Overload |
1.2 x rating continuously, 1.5 x rating for 10 x seconds to symmetric |
Trip level adjustment |
Trip level adjustment Pre-set at 85% of nominal |
Auxiliary voltage burden |
Auxiliary voltage burden 4VA (max) |
Output relay |
Output relay 2-pole change over |
Relay contact rating |
Relay contact rating AC: 240V 5A, non inductive |
|
DC: 24V 5A resistive |
Relay mechanical life |
Relay mechanical life 0.2 million operations at rated loads |
Relay reset |
Relay reset Automatic |
Operating temperature |
Operating temperature 0°C to +60°C (0°C to +40°C for UL models) |
Storage temperature |
Storage temperature –20°C to +70°C |
Temperature co-efficient |
Temperature co-efficient 0.05% per °C |
Interference immunity |
Electrical stress surge withstand and non-function to ANSI/IEEE C37 90a |
Enclosure style |
DIN-rail with wall mounting facility |
Material |
Flame retardant polycarbonate/ABS |
Enclosure integrity |
IP50 |
Model 252 dimensions |
55mm (2.2") wide x 70mm (2.8") high x 112mm (4.4") deep |
Weight |
0.4Kg approx. |
Dimensions
Model 252
Connections
252-PVR
Note: No neutral connection is required.
Danh mục sản phẩm
System |
Input |
Protection |
Catalog Number |
Phase Sequence & Phase Failure |
3 Phase 3 or 4 Wire |
120V L-L 60 Hz |
Phase Sequence, Under Voltage |
252-PVRU-PQBX-C6 |