SINAMICS G120 standard inverters are available in different versions for safety-related applications. The PM240‑2 and PM250 Power Modules are already designed for Safety Integrated. PM240 Power Modules, frame size FSGX (i.e. 160 kW/250 hp and higher) are approved only for the Basic Safety functions (STO, SS1, and SBC). A drive can be combined with a Control Unit with safety functions (see overview) in order to create a Safety Integrated drive. The availability of Safety Integrated functions depends on the type of Control Unit.
Control Unit |
Basic Safety functions |
Extended Safety functions |
||||
---|---|---|---|---|---|---|
|
STO |
SS1 |
SBC 1) |
SLS |
SDI |
SSM |
CU230P‑2 |
– |
– |
– |
– |
– |
– |
CU240E‑2 |
✓ |
– |
– |
– |
– |
– |
CU240E‑2 F |
✓ |
✓ |
– |
✓ |
✓ |
✓ 2) |
CU250S‑2 |
✓ |
✓ |
✓ |
✓ 3) |
✓ 3) |
✓ 3) |
1) The SBC function can be utilized only if a Safe Brake Relay is installed.
2) SSM possible only for CU240E‑2 DP‑F / CU240E‑2 PN‑F Control Units with PROFIsafe.
3) With license for Extended Safety functions.
Basic Safety functions (certified according to IEC 61508 SIL 2, and EN ISO 13849‑1 PL d and Category 3)
- Safe Torque Off (STO)Extended Safety functions (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3)
- Safely Limited Speed (SLS)Basic Safety and Extended Safety functions can be activated via PROFIsafe or by means of the safety inputs.
None of the safety functions require a motor encoder and they are thus cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never accelerate when the inverter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
Additional information is provided in chapter Highlights, section Safety Integrated.
The innovative Efficient Infeed Technology is employed in PM250 Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. For control cabinets, an additional temperature rise can be avoided and the amount of space required can be reduced due to the fact that components such as braking resistors, braking choppers and line reactors can be eliminated. Further, wiring and engineering costs are significantly reduced. At the same time, energy consumption can be reduced and ongoing operating costs noticeably reduced.
Additional information is provided in chapter Highlights, section Efficient Infeed Technology.
The new cooling system and varnishing of the electronic modules significantly increases the service life or useful life of the device.
Integrated technologies help when optimizing the energy usage of the plant or system referred to the particular application:
- Energy-efficient vector control with or without sensorsAdditional information is provided in chapter Highlights, section Energy efficiency.
Voltage |
1/3AC 200 … 240 V +/- 10 % |
Power range |
0.55 kW – 250 kW (LO) |
Degree of protection |
IP20 |
Environmental class |
Class 3C2, (3C3 with SIPLUS) |
Ambient temperature |
0 to 50°C |
EMC |
According to IEC 61800-3 up to Category C2 |
Standards |
CE, UL, cUL, c-Tick |
Safety Technology |
Safety Integrated: STO (SIL 3, PL e, Kat. 3), SS1, SBC, SLS, SDI, SSM, PROFIsafe |
Communication |
PROFINET, PROFIBUS, USS, Modbus, Ethernet IP, BACnet |
Control procedure |
U/f, Flux Current Control, vector control with and without encoder |
Functions |
Basic positioning function with Epos, regenerative capability through efficient infeed technology (Power Modules PM250 only), PROFIenergy, PROFIdrive |
Selecting the Control Unit
The optimum Control Unit is selected first, based on the number of I/Os and any additional functions required such as Safety Integrated or HVAC. The communication options are already integrated and do not have to be additionally ordered or plugged in. Three product series are available corresponding to the particular application.
CU230P‑2 Control Units
The CU230P‑2 Control Units have been specifically designed for pump, fan and compressor applications.
The CU230P‑2 is the Control Unit for the pump, fan and compressor inverters SINAMICS G120P and SINAMICS G120P Cabinet. Detailed information can be found in Catalog D 35.
Control Unit CU240E‑2
The CU240E‑2 Control Unit is suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders.
Description |
Fieldbus |
Profile |
Inputs |
Integrated safety technology |
Fail-safe |
Control Unit |
---|---|---|---|---|---|---|
|
|
|
|
|
|
Article No. |
CU230P‑2 series - the specialist for pumps, fans, compressors, water, buildings Technology functions (selection): Free function blocks (FFB), 4 × PID controller, cascade connection, hibernation mode, essential service mode, multi-zone control |
||||||
CU230P‑2 HVAC |
|
– |
6 DI 3 DO |
– |
– |
6SL3243-0BB30-1HA3 |
CU230P‑2 DP |
|
|
6SL3243-0BB30-1PA3 |
|||
CU230P‑2 PN |
|
|
6SL3243-0BB30-1FA0 |
|||
|
– |
|||||
CU240E‑2 series – for standard applications in general machinery construction, such as conveyor belts, mixers and extruders – without encoder Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake |
||||||
CU240E‑2 |
|
– |
6 DI 3 DO |
STO |
1 F-DI |
6SL3244-0BB12-1BA1 |
CU240E‑2 DP |
|
|
6SL3244-0BB12-1PA1 |
|||
CU240E‑2 PN |
|
|
6SL3244-0BB12-1FA0 |
|||
|
– |
|||||
CU240E‑2 F |
|
– |
STO, SS1, SLS, SDI |
3 F-DI |
6SL3244-0BB13-1BA1 |
|
CU240E‑2 DP‑F |
|
|
STO, SS1, SLS, SSM 1), SDI |
6SL3244-0BB13-1PA1 |
||
CU240E‑2 PN‑F |
|
|
6SL3244-0BB13-1FA0 |
|||
|
– |
|||||
CU250S‑2 series – for complex applications such as extruders and centrifuges – with and without encoder (basic positioner (EPos) optional) Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake |
||||||
CU250S‑2 |
|
– |
11 DI 3 DO 4 DI/DO (DI can be used as high-speed inputs) |
STO, SBC, SS1 |
3 F-DI 1 F-DO |
6SL3246-0BA22-1BA0 |
CU250S‑2 DP |
|
|
6SL3246-0BA22-1PA0 |
|||
CU250S‑2 PN |
|
|
6SL3246-0BA22-1FA0 |
|||
|
– |
|||||
CU250S‑2 CAN |
|
– |
6SL3246-0BA22-1CA0 |
1) SSM is possible only with PROFIsafe.
Description |
Suitable for |
Article No. |
---|---|---|
SINAMICS SD card 512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) |
CU230P‑2 |
6SL3054-7TD00-2BA0 |
Description |
SINAMICS SD card |
SINAMICS SD card |
Licenses (without SD card) |
---|---|---|---|
|
Article No. |
Article No. |
Article No. |
License Extended Functions |
6SL3054-4AG00-2AA0-Z E01 |
6SL3054-7TD00-2BA0-Z E01 |
6SL3074-7AA04-0AA0 |
License Extended Functions |
6SL3054-4AG00-2AA0-Z F01 |
6SL3054-7TD00-2BA0-Z F01 |
6SL3074-0AA10-0AA0 |
Licenses Extended Functions |
6SL3054-4AG00-2AA0-Z E01+F01 |
6SL3054-7TD00-2BA0-Z E01+F01 |
– |
For additional information about firmware V4.7 SP6:
https://support.industry.siemens.com/cs/document/109482094
Description |
Suitable for |
Article No. |
---|---|---|
SINAMICS SD card 512 MB + firmware V4.6 (Multicard V4.6) |
CU230P‑2 |
6SL3054-7EG00-2BA0 |
SINAMICS SD card 512 MB + firmware V4.7 (Multicard V4.7) |
CU230P‑2 |
6SL3054-7EH00-2BA0 |
For an overview and more information on all available firmware versions, see https://support.industry.siemens.com/cs/document/67364620
The optimum power unit can be quickly selected based on the required motor power, the supply voltage and the braking cycles to be expected. Power Modules in degree of protection IP20 are intended for installation in a control cabinet.
PM240‑2 and PM240 Power Modules – IP20 degree of protection
PM240‑2 Power Modules have an integrated braking chopper (four-quadrant applications) and are suitable for a large number of applications in general machinery construction. The same applies for PM240 Power Modules, but the PM240 Power Modules in frame size FSGX do not have an integrated braking chopper. A plug-in Braking Module is optionally available for this purpose.
PM250 Power Modules – degree of protection IP20
PM250 Power Modules are suitable for the same applications as the PM240‑2/PM240. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking resistor is not required).
The Power Modules can be combined with the following Control Units:
Control Units |
Power Modules degree of protection IP20 |
|
---|---|---|
|
PM240‑2/PM240 |
PM250 |
CU230P‑2 |
✓ |
✓ |
CU240E‑2 |
✓ |
✓ |
CU250S‑2 |
✓ |
✓ |