Unless explicitly specified otherwise, the following technical specifications are valid for all components of the SINAMICS S120 booksize drive system.
Note:
When engineering the complete SINAMICS S120 drive, the system data of the associated Control Units, supplementary system components, DC link components and Sensor Modules must be taken into consideration.
Electrical specifications |
|||
Line voltage |
380 ... 480 V 3 AC ±10 % (-15 % <1 min) |
||
Line system configurations |
Grounded TN/TT systems and non-grounded IT systems |
||
Line frequency |
47 ... 63 Hz |
||
Electronics power supply |
24 V DC -15 %/+20 %1), safety extra low-voltage (PELV/SELV) |
||
Short-circuit current rating (SCCR) (Short Circuit Current Rating) |
1.1 ... 447 kW: 65 kA |
||
Electromagnetic compatibility According to EN 61800‑3 |
Second environment, Category C2/C3 For further information, see section Configuration notes |
||
Overvoltage category According to IEC/EN 61800‑5‑1 |
III |
||
Mechanical specifications |
|||
Degree of protection |
|
||
|
IP20 |
||
|
Open type |
||
Protection class |
|
||
|
I |
||
|
Safety extra low-voltage PELV/SELV |
||
Ambient conditions |
|||
|
Storage |
Transport |
Operation |
In product packaging |
In transport packaging |
|
|
Climatic environmental conditions |
Class 1K4 |
Class 2K4 |
Class 3K3 3) Relative humidity 5 ... 95 % |
Environmental class/harmful chemical substances |
Class 1C2 |
Class 2C2 |
Class 3C2 |
Organic/biological influences |
Class 1B1 |
Class 2B1 |
Class 3B1 |
Pollution degree 2) acc. to IEC/EN 61800‑5‑1 |
2 |
||
Installation altitude |
|
||
|
Without derating |
||
|
|
||
|
|
||
|
and additionally:
|
||
|
|
||
Mechanical strength |
|||
|
Storage |
Transport |
Operation |
In product packaging |
In transport packaging |
|
|
Vibratory load |
Class 1M2 |
Class 2M3 |
Class 3M1 |
Shock load |
Class 1M2 |
Class 2M3 |
Class 3M1 |
Certificates |
|||
Declarations of conformity |
CE (Low Voltage, EMC and Machinery Directive) |
||
Certificates of suitability |
cULus |
1) When using a motor holding brake, restricted voltage tolerances (24 V ±10 %) might need to be taken into account.
2) The components must be protected against conductive pollution, e.g. by installing them in a control cabinet with degree of protection IP54 according to IEC 60529 or NEMA 12. If conductive pollution can be excluded at the installation site, a lower degree of cabinet protection is permissible.
3) Better than 3K3 through increased ruggedness regarding the temperature range and humidity. Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing water and water jets are not permitted.
4) Also carefully observe the permissible temperatures for the Control Unit and operator panel.
Smart Line Modules are stall-protected, line-commutated infeed/regenerative feedback units (diode bridge for incoming supply; stall-protected, line-commutated regenerative feedback via IGBTs) with 100 % continuous regenerative feedback power. The regenerative feedback capability of the modules can be deactivated by means of a digital input (Smart Line Modules 5 kW and 10 kW) or by means of parameterization (Smart Line Modules 16 kW, 36 kW and 55 kW). Smart Line Modules are designed for connection to grounded TN/TT systems and non-grounded IT systems.
The DC link is pre-charged via integrated precharging resistors.
The associated line reactor is required for operating a Smart Line Module.
The Smart Line Modules in booksize format feature the following connections and interfaces as standard:
The status of the Smart Line Modules is indicated via two multi-color LEDs.
The signal cable shield can be connected to the Line Module by means of a shield connection terminal, e.g. Weidmüller type KLBÜ 3-8 SC.
The scope of supply of the Smart Line Modules includes:
Connection example of 5 kW and 10 kW Smart Line Modules in booksize format
Connection example of 16 kW, 36 kW and 55 kW Smart Line Modules in booksize format
|
Smart Line Module in booksize format 6SL313... |
---|---|
Line voltage (up to 2000 m (6562 ft) above sea level) |
380 ... 480 V 3 AC ±10 % (in operation -15 % <1 min) |
Line frequency |
47 ... 63 Hz |
SCCR (short-circuit current rating) |
65 kA in conjunction with the recommended Class J fuse, or circuit breaker according to UL489 / CSA 22.2 No. 5-02 see recommended line-side components |
Line power factor at rated power |
|
|
>0.96 |
|
0.65 ... 0.9 |
Overvoltage category according to EN 60664‑1 |
Class III |
DC link voltage, approx. |
1.35 × line voltage1) |
Electronics power supply |
24 V DC -15 %/+20 % |
Radio interference suppression |
|
|
No radio interference suppression |
|
Category C2 to EN 61800‑3 |
Type of cooling |
Internal air cooling (power units with increased air cooling using an integrated fan) |
Permissible ambient and coolant temperature (air) during operation for line-side components, Line Modules and Motor Modules |
0 ... 40 °C (32 ... 104 °F) without derating, |
Installation altitude |
Up to 1000 m (3281 ft) above sea level without derating, |
Declarations of conformity |
CE (Low Voltage and EMC Directives) |
Certificate of suitability |
cULus |
1) The DC link voltage is maintained at the mean value of the rectified line voltage. For further information, see section Configuration notes.
Line voltage 380 ... 480 V 3 AC |
Smart Line Module in booksize format |
|||||
---|---|---|---|---|---|---|
Internal air cooling |
6SL3130-6AE15-0AB1 |
6SL3130-6AE21-0AB1 |
6SL3130-6TE21-6AA4 |
6SL3130-6TE23-6AA3 |
6SL3130-6TE25-5AA3 |
|
Infeed/regenerative feedback power |
|
|
|
|
|
|
|
||||||
|
kW |
5 |
10 |
16 |
36 |
55 |
|
(hp) |
(5) |
(10) |
(18) |
(40) |
(60) |
|
kW |
6.5 |
13 |
21 |
47 |
71 |
|
kW |
10 |
20 |
35 |
70 |
91 |
DC link current |
|
|
|
|
|
|
|
A |
9.3/8.3 |
18.5/16.6 |
30/27 |
67/60 |
105/92 |
|
A |
11 |
22 |
35 |
79 |
138 |
|
A |
16.6 |
33.2 |
59 |
118 |
178 |
Input current |
|
|
|
|
|
|
|
A |
8.6/8.1/6.7 |
17/16.2/12.8 |
29/27.5/24.5 |
62/59/51 |
94/90/77 |
|
A |
10.6 |
21.1 |
35 |
76 |
106 |
|
A |
15.7 |
31.2 |
57.5 |
112 |
130 |
Current requirement 24 V DC electronics power supply, max. |
A |
0.8 |
0.9 |
0.95 |
1.5 |
1.9 |
Current carrying capacity |
|
|
|
|
|
|
|
A |
20 |
20 |
20 |
20 |
20 |
|
A |
100 |
100 |
100 |
200 |
200 |
DC link capacitance |
|
|
|
|
|
|
|
μF |
220 |
330 |
710 |
1410 |
1880 |
|
μF |
6000 |
6000 |
20000 |
20000 |
20000 |
Power loss 1) |
kW |
0.08 |
0.14 |
0.19 |
0.406 |
0.666 |
Cooling air requirement |
m3/s (ft3/s) |
0.008 (0.3) |
0.008 (0.3) |
0.016 (0.6) |
0.031 (1.1) |
0.044 (1.5) |
Sound pressure level LpA (1 m) |
dB |
<60 |
<60 |
<60 |
<65 |
<60 |
Line connection U1, V1, W1 |
|
Screw-type terminals (X1) |
Screw-type terminals (X1) |
Screw-type terminals (X1) |
M6 screw studs (X1) |
M6 screw studs (X1) |
|
mm2 |
2.5 ... 6 |
2.5 ... 6 |
2.5 ... 10 |
2.5 ... 50 |
2.5 ... 95 |
Shield connection |
|
Shield connection plate integrated into the connector |
Shield connection plate integrated into the connector |
Shield connection plate integrated into the connector |
See Accessories |
See Accessories |
PE connection |
|
M5 screw |
M5 screw |
M5 screw |
M6 screw |
M6 screw |
Cable length, max. (total of all motor power cables |
|
|
|
|
|
|
|
m (ft) |
350 (1148) |
350 (1148) |
630 (2067) |
630 (2067) |
1000 (3281) |
|
m (ft) |
560 (1837) |
560 (1837) |
850 (2789) |
850 (2789) |
1500 (4922) |
Degree of protection |
|
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
Dimensions |
|
|
|
|
|
|
|
mm (in) |
50 (1.97) |
50 (1.97) |
100 (3.94) |
150 (5.91) |
200 (7.87) |
|
mm (in) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
380 (14.96) |
|
mm (in) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
270 (10.63) |
Weight, approx. |
kg (lb) |
4.7 (10.4) |
4.8 (10.6) |
7 (15.4) |
10 (22.0) |
17 (37.5) |
1) Power loss of Smart Line Module at rated output including losses of 24 V DC electronics power supply.
2) Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and are to be dimensioned accordingly.
Duty cycle with previous load
S6 duty cycle with previous load
S6 duty cycle with previous load
Output power as a function of ambient temperature
Output power as a function of total cable length
Installation altitude
- >1000 ... 4000 m (3281 ... 13124 ft) above sea level