range of product | Altistart 48 | |
product or component type | Soft starter | |
product destination | Asynchronous motors | |
product specific application | Heavy duty industry and pumps | |
device short name | ATS48 | |
power supply voltage | 230...415 V - 15...10 % | |
motor power kW | 630 kW at 400 V connection to the motor delta terminals for standard applications 220 kW at 230 V connection in the motor supply line for standard applications 315 kW at 230 V connection to the motor delta terminals for severe applications 355 kW at 230 V connection to the motor delta terminals for standard applications 355 kW at 400 V connection in the motor supply line for severe applications 400 kW at 400 V connection in the motor supply line for standard applications 500 kW at 400 V connection to the motor delta terminals for severe applications |
|
power dissipation in W | 2073 W for standard applications 2537 W for standard applications |
|
utilisation category | AC-53A | |
type of start | Start with torque control (current limited to 5 In) | |
Icl nominal current | 790 A for connection in the motor supply line for standard applications 790 A for connection in the motor supply line for severe applications 1368 A for connection to the motor delta terminals for standard applications 1368 A for connection to the motor delta terminals for severe applications |
|
IP degree of protection | IP00 |
assembly style | With heat sink | |
function available | External bypass (optional) | |
power supply voltage limits | 195…456 V | |
power supply frequency | 50...60 Hz - 5...5 % | |
power supply frequency limits | 47.5...63 Hz | |
device connection | In the motor supply line To the motor delta terminals |
|
factory setting current | 675 A | |
[Uc] control circuit voltage | 220 - 15 % to 415 + 10 %, 50/60 Hz | |
control circuit consumption | 80 W | |
discrete output number | 2 | |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
|
output absolute accuracy precision | +/- 5 % | |
minimum switching current | 10 mA at 6 V DC for relay outputs | |
maximum switching current | Logic output 0.2 A at 30 V DC Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms |
|
discrete input number | 5 | |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
|
discrete input voltage | 24 V <= 30 V | |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA | |
starting current | 0.4...1.3 Icl adjustable | |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm | |
communication port protocol | Modbus | |
connector type | 1 RJ45 | |
communication data link | Serial | |
physical interface | RS485 multidrop | |
transmission rate | 4800, 9600 or 19200 bps | |
max nodes number | 31 | |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
|
marking | CE | |
type of cooling | Forced convection | |
operating position | Vertical +/- 10 degree | |
height | 890 mm | |
width | 770 mm | |
depth | 315 mm | |
net weight | 115 kg | |
Motor power range AC-3 | 110…220 kW at 200…240 V 3 phases 250…500 kW at 380…440 V 3 phases 250…500 kW at 200…240 V 3 phases 560…900 kW at 380…440 V 3 phases |
|
motor starter type | Soft starter |
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
|
standards | EN/IEC 60947-4-2 | |
product certifications | SEPRO C-Tick TCF GOST UL CCC CSA DNV NOM 117 |
|
vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 |
|
shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 | |
noise level | 60 dB | |
pollution degree | Level 3 conforming to IEC 60664-1 | |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
|
ambient air temperature for storage | -25…70 °C | |
operating altitude | <= 1000 m without derating > 1000...2000 m with current derating of 2.2 % per additional 100 m |
Sustainable offer status | Green Premium product | |
REACh Regulation | REACh Declaration | |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
|
Mercury free | Yes | |
RoHS exemption information | Yes | |
China RoHS Regulation | China RoHS declaration | |
Environmental Disclosure | Product Environmental Profile | |
Circularity Profile | End of Life Information | |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 18 months |