With display |
Yes |
Voltage type for actuating |
AC |
Rated operating voltage Ue |
230 V |
Rated control supply voltage at AC 50 Hz |
100 V |
Rated control supply voltage at AC 60 Hz |
100 V |
Overload current for line connected devices |
27 A |
Overload current for delta connected devices |
47 A |
Controller type |
Soft starter |
Control options |
None |
Trip classes |
10, 15, 20 and 30 |
Trip current rating |
117% of motor FLC |
Transformer control module |
75VA @ 100...240V AC (-15%, +10%) |
Heatsink fan rating |
20VA @ 110/120V AC or 220/240V AC |
Repetitive peak inverse voltage rating |
1800V per UL/CSA/NEMA for power circuit |
Operating frequency |
50/60 Hz for power circuit |
Line connected motor power, max |
90 kW @ 690V/Y AC, 50 Hz, 3-phase |
Delta connected motor power, max |
90 kW @ 400/415V AC, 50 Hz, 3-phase |
Rated impulse voltage |
6000V per IEC for power circuit |
Dielectric withstand |
2500V per IEC for power circuit |
Line connected motor current |
27...108 A @ 600/Y/690V AC, 3-phase |
Delta connected motor current |
47...187 A @ 500/575V AC, 3-phase |
Ampere tested european style, max |
6,9 gRB 73xxx400 6,6URD33xxx500 @ 690V for maximum FLC |
Ampere tested north american style, max |
A070URD33xxx500 @ 690V for maximum FLC |
Insulation voltage |
Rated 690V per IEC for power circuit |
Rated operational voltage |
230...690V/Y (–15%, +10%) per IEC for power circuit |
Input OFF-state current |
<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage |
Short-circuit protection device list |
Standard fuse, circuit breaker and high capacity time delay class CC/J/L |
Number of contacts |
1 for auxiliary contacts |
High capacity available fault current, max |
70 kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors |
Type of current |
AC for auxiliary contacts |
Conventional thermal current (Ith) |
AC/DC: 5 A for auxiliary contacts |
Type of control circuit |
Electromagnetic relay for auxiliary contacts |
Type of contacts |
Programmable NO/NC for auxiliary contacts |
Utilization category |
MG 1 per UL/CSA/NEMA for power circuit |
Standard controller feature |
Status indication: stopped, starting, stopping, at speed, alarm and fault |
Standard available fault current, max |
70 kA @ 690V for maximum FLC |
Optional controller feature |
SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating |
Integrated motor overload protection |
Yes |
Short circuit protection device performance (SCPD) type |
Type 1 |
Number of sensors, max |
6 for PTC input ratings |
Inrush current control module |
5 A @ 24V DC (-15%, +10%) |
Voltage at PTC terminals (RPTC = open), max |
30V for PTC input ratings |
Transient watts control module |
60 W @ 24V DC (-15%, +10%) |
Steady state watts control module |
24 W @ 24V DC (-15%, +10%) |
Voltage at PTC terminals (RPTC = 4 kΩ), max |
<7.5 for PTC input ratings |
Response time |
800 ms for PTC input ratings |
Inrush time control module |
250 ms @ 24V DC (-15%, +10%) |
Transient time control module |
500 ms @ 24V DC (-15%, +10%) |
Cold resistance of PTC sensor chain, max |
1500 Ohm for PTC input ratings |
Tachometer input |
0...5V DC, 4.5V DC = 100% Speed |
Allen bradley power supply control module, min |
1606-XLP50E @ 24V DC (-15%, +10%) |
Short circuit trip resistance |
25 Ohm ± 10 Ohm for PTC input ratings |
Response resistance |
3400 Ohm ± 150 Ohm for PTC input ratings |
Reset resistance |
1600 Ohm ± 100 Ohm for PTC input ratings |
Input OFF-state voltage, max |
50V AC, 10V DC/12V AC for control circuit |
Input ON-state voltage, min |
85V AC, 19.2V DC/20.4V AC for control circuit |
Rated operational current |
3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts |
Input ON-state current |
20 mA @ 120V AC/40mA @ 240V AC, 7.6 mA @ 24V AC/DC for control circuit |
Contact type |
auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4) |