Rờ le an toàn giám sát cửa Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 - 2981428 | Safety relays

(SIL3  Cat.4 3NO 1NC 2NO 0.2-300s 250V AC/DC 6A Coil 24VDC)


Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e (EN ISO 13849), one- or two-channel operation, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with dropout delay of 0.2 s to 300 s, plug-in screw terminal block
 

Your advantages

- Maximum of 3 undelayed and 2 dropout delay contacts
- Manually monitored and automatic activation
- Up to Cat. 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
- For emergency stop and safety door monitoring, plus evaluation of light grids
- Single and two-channel control
- Adjustable delay time of 0.2 s ... 300 s (24 increments)
- Protective labels to prevent manipulation of the set time (PSR-ESD-300) or electronic protection against manipulation (PSR-ESD-30)
 

Bản vẽ kỹ thuật


Circuit diagram


Circuit diagram
Two-channel safety door monitoring
 

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width 45 mm
Height 99 mm
Depth 114.5 mm

Ambient conditions

Ambient temperature (operation) -20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 70 °C
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Maximum altitude ≤ 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US 24 V DC -15 % / +10 %
Rated control supply current IS typ. 155 mA
Power consumption at US typ. 3.72 W
Inrush current 200 mA (at US)
  < 40 mA (with Us/Ito S10)
  < 150 mA (with Us/Ito S12)
  > -60 mA (with Us/Ito S22)
  < 40 mA (with Us/Ito S34)
  < 40 mA (with Us/Ito S35)
Current consumption < 40 mA (with Us/Ito S10)
  < 50 mA (with Us/Ito S12)
  > -40 mA (with Us/Ito S22)
  0 mA (with Us/Ito S34)
  < 5 mA (with Us/Ito S35)
Voltage at input/start and feedback circuit 24 V DC -15 % / +10 %
Typical response time < 600 ms (automatic start)
  < 70 ms (manual start)
Typ. starting time with Us < 600 ms (when controlled via A1)
Typical release time < 20 ms (when controlled via S11/S12 and S21/S22)
  < 20 ms (when controlled via A1)
Concurrence
Recovery time < 1 s
Operating voltage display 1 x green LED
Status display 4 x green LEDs
Protective circuit Surge protection Suppressor diode
Maximum switching frequency 0.5 Hz
Max. permissible overall conductor resistance approx. 22 Ω (Input and start circuits at US)
Filter time 1 ms (at A1 in the event of voltage dips at Us)
  max. 1.5 ms (at S10, S12; test pulse width)
  7.5 ms (at S10, S12; test pulse rate)
  Test pulse rate = 5 x Test pulse width

Output data

Contact type 5 enabling current paths
  1 signaling current path
Contact material AgSnO2
Maximum switching voltage 250 V AC/DC (Observe the load curve)
Minimum switching voltage 5 V AC/DC
Limiting continuous current 6 A (N/O contact, pay attention to the derating)
  6 A (N/C contact)
Maximum inrush current 20 A (Δt  100 ms, undelayed contacts)
  8 A (delayed contacts)
Inrush current, minimum 10 mA
Sq. Total current 55 A2 (observe derating)
Interrupting rating (ohmic load) max. 144 W (24 V DC, τ = 0 ms)
  288 W (48 V DC, τ = 0 ms)
  110 W (110 V DC, τ = 0 ms, delayed contacts: 77 W)
  88 W (220 V DC, τ = 0 ms)
  1500 VA (250 V AC, τ = 0 ms, delayed contacts: 2000 VA)
Maximum interrupting rating (inductive load) 42 W (24 V DC, τ = 40 ms, delayed contacts: 48 W)
  42 W (48 V DC, τ = 40 ms, delayed contacts: 40 W)
  42 W (110 V DC, τ = 40 ms, delayed contacts: 35 W)
  42 W (220 V DC, τ = 40 ms, delayed contacts: 33 W)
Switching capacity min. 50 mW
Mechanical service life 10x 106 cycles
Switching capacity (360/h cycles) 4 A (24 V DC)
  4 A (230 V AC)
Output fuse 10 A gL/gG (N/O contact)
  6 A gL/gG (N/C contact)

General

Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Nominal operating mode 100% operating factor
Net weight 430 g
Mounting position any
Mounting type DIN rail mounting
Degree of protection IP20
Min. degree of protection of inst. location IP54
Housing material PBT
Housing color yellow

Connection data

Connection method Screw connection
pluggable Yes
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG 24 ... 12
Stripping length 7 mm
Screw thread M3

Safety-related characteristic data

Stop category in accordance with IEC 60204 0
  1
Designation IEC 61508 - High demand
Safety Integrity Level (SIL) 3 (for delayed contacts SIL 2)
Designation IEC 61508 - Low demand
Safety Integrity Level (SIL) 3 (for delayed contacts SIL 2)
Designation EN ISO 13849
Performance level (PL) e (for delayed contacts PL d)
Category 4 (Undelayed contacts)
  3 (delayed contacts)
Designation EN 62061
Safety Integrity Level Claim Limit (SIL CL) 3 (for delayed contacts SILCL 2)

Standards and Regulations

Designation Air clearances and creepage distances between the power circuits
Standards/regulations DIN EN 50178/VDE 0160
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Basic insulation 4 kV:
between all current paths and housing
Safe isolation, reinforced insulation 6 kV:
between 13/14, 23/24, 33/34, and the remaining current paths
between 13/14, 23/24, 33/34 among one another
Degree of pollution 2
Overvoltage category III
Shock 15g
Vibration (operation) 10 Hz ... 150 Hz, 2g
Conformance CE-compliant

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

ECLASS

ECLASS 10.0.1 27371819
ECLASS 11.0 27371819
ECLASS 4.0 40020600
ECLASS 4.1 40020600
ECLASS 5.0 27371900
ECLASS 5.1 27371900
ECLASS 6.0 27371800
ECLASS 7.0 27371819
ECLASS 9.0 27371819

ETIM

ETIM 2.0 EC001449
ETIM 3.0 EC001449
ETIM 4.0 EC001449
ETIM 6.0 EC001449
ETIM 7.0 EC001449

UNSPSC

UNSPSC 6.01 30211901
UNSPSC 7.0901 39121501
UNSPSC 11 39121501
UNSPSC 12.01 39121501
UNSPSC 13.2 39121501
UNSPSC 18.0 39122205
UNSPSC 19.0 39122205
UNSPSC 20.0 39122205
UNSPSC 21.0 39122205
 

- Xem chi tiết Tài liệu kỹ thuật/ Datasheet Rờ le an toàn giám sát cửa Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 - 2981428


Sản phẩm cùng loại
SẢN PHẨM XEM NHIỀU
Hãy xem RCCB và ELCB cứu bạn thoát chết vì điện giựt thế nào!Hãy xem tầm qua trong của RCCB và ELCB trong việc cứu nạn nhân bị điện giựt thoát chết như thế nào..
Wiki - Tìm hiểu về lắp đặt hệ thống điện trong nhà máy, tòa nhà...Lắp điện là lắp đặt, đấu nối hệ thống dây, cáp điện động lực, điều khiển, truyền thông và chác thiết bị liên quan như thiết bị chuyển mạch (CB), tủ điện
Circuit Breakers (CB) hoạt động thế nào?
Bộ ngắt điện hay còn gọi là máy cắt (Circuit breaker-CB) là thiết bị được thiết kế để bảo vệ một mạch điện khỏi bị hư hỏng gây ra bởi dòng điện
Programmable logic controller
A programmable logic controller (PLC), or programmable controller is an industrial digital computer which has been ruggedisedand adapted for the control of
White paper về Lý thuyết điều khiển tự độngLý thuyết điều khiển tự động là một nhánh liên ngành của kỹ thuật và toán học, liên quan đến hành vi của
Hướng dẫn Lập trình PLC chi tiết cho người mới tìm hiểu (Part 1)Điều khiển quá trình (PLC) được sử dụng rộng rãi trong công nghiệp và cho phép sản xuất hàng loạt các sản phẩm phù hợp với các
10 Dự báo về Internet Of Things (IoT) năm 2018Trong một báo cáo mới, dự đoán năm 2018: IoT chuyển từ thử nghiệm sang kinh doanh quy mô, Forrester Research dự đoán rằng IoT sẽ trở thành xương sống của
Top 15 Loại cảm biến Sensor được dùng nhiều trong các thiết bị IoTNền tảng IoT hoạt động và cung cấp các dạng thông minh và dữ liệu có giá trị với việc sử dụng nhiều cảm biến khác nhau. Chúng phục vụ để thu
HVAC control system
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air
Năng lượng tương lai: Photovoltaic hay Hydrogen?Hydrogen là một nguyên tố chiếm tỷ lệ cao nhất so với tất cả các nguyên tố khác trên địa cầu. Nhưng hydrogen không hiện diện dưới dạng nguyên tử hay
Năng lượng tái tạo : Một loại ắc quy mới nhiều hứa hẹnNăng lượng tái tạo như điện gió và điện mặt trời có một nhược điểm căn bản, đó là không ổn định. Chúng chỉ vận hành khi có
Chất thải từ người là năng lượng tương lai?BBC Future - Hành tinh của chúng ta gặp một vấn đề. Con người, như tất cả các sinh vật sống khác, thải ra rất nhiều những chất thải không dễ chịu
Tin vui cho phái đẹp: Robot Spermbot có thể giúp điều trị ung thư cổ tử cungKhi robot sinh học này phát hiện ra khối u, bốn cánh tay trên cấu trúc vi mô tự động uốn cong, giải phóng tế bào tinh trùng, xâm
Tương lai nào cho trí tuệ nhân tạo - Artificial intelligence (AI)?
Trí thông minh nhân tạo (AI) là khả năng của một chương trình máy tính hoặc một máy tính để suy nghĩ và học hỏi. Nó
Bạn Biết Có Bao Nhiêu Loại Robot - ROBOTPARK
Các loại Robot là gì? Dưới đây là các loại robot của hệ thống vận động. Chúng tôi sẽ kiểm tra các loại này một cách
Gọi điện thoại