Product type | Charger |
Product family | QUINT CHARGER |
MTBF (IEC 61709, SN 29500) | > 500000 h (230 V AC, at 40 °C) |
Insulation characteristics | |
Protection class | I |
Degree of pollution | 2 |
Number of phases | 1.00 |
AC operation | |
Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
Derating | < 90 V AC (2.5 %/V) |
Frequency range (fN) | 50 Hz ... 60 Hz ±10 % |
Current consumption | 2.7 A (100 V AC) |
1.2 A (240 V AC) | |
Input fuse | 6.3 A (internal (device protection), slow-blow) |
Recommended breaker for input protection | 10 A ... 16 A (AC: Characteristic B, C, D, K, or comparable) |
DC operation | |
Input voltage range | 110 V DC ... 250 V DC |
Current consumption | 2.4 A (110 V DC) |
1.1 A (250 V DC) | |
Digital Control (configurable) | |
Designation | Remote / Service |
Efficiency | 89 % |
91 % | |
Nominal output voltage | 24 V DC |
Setting range of the output voltage (USet) | 19.2 V DC ... 28.6 V DC |
Nominal output current (IN) | 10 A |
Residual ripple | < 20 mVPP |
Short-circuit-proof | yes |
No-load proof | yes |
Output power | 240 W |
Maximum no-load power dissipation | < 4 W (for 230 V AC) |
Power loss nominal load max. | < 35 W (for 230 V AC) |
Connection in parallel | no |
Connection in series | No |
Signal: UIn OK | |
Output voltage | 24 V DC |
Continuous load current | 20 mA |
Signal ground SGnd | Reference ground signal contacts |
Signal: Bat.-Voltage OK | |
Output voltage | 24 V DC |
Continuous load current | 20 mA |
Signal ground SGnd | Reference ground signal contacts |
Signal: Alarm | |
Output voltage | 24 V DC |
Continuous load current | 20 mA |
Signal ground SGnd | Reference ground signal contacts |
Nominal voltage UN | 24 V DC |
Charging voltage | max. 32 V DC |
Charging current | typ. 10 A |
Nominal capacity range | 7 Ah ... 300 Ah |
Battery technology | VRLA, VRLA-WTR, LI-ION (LiFePO4) |
Charge characteristic curve | IU |
Input | |
Connection method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 6.5 mm |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Output | |
Connection method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 6.5 mm |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signal | |
Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Interface | MINI-USB type B |
Signal output: Transistor output, active | |
Signalization designation | UIn OK |
Status display | Green LED |
Signal output: Transistor output, active | |
Signalization designation | Bat.-Voltage OK |
Status display | Green LED |
Signal output: Transistor output, active | |
Signalization designation | Alarm |
Status display | LED red |
Signal output | |
Signalization designation | Reference potential for the signal inputs and outputs |
Width | 60 mm |
Height | 130 mm |
Depth | 126 mm |
Installation dimensions | |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Alternative assembly | |
Width | 123 mm |
Height | 130 mm |
Depth | 63 mm |
Housing material | Metal |
Hood version | High-grade steel plate |
Side element version | Aluminum |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 4000 m (> 2000 m, observe derating) |
Climatic class | 3K3 (EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (At +25°C, non-condensing) |
Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
Vibration (operation) | 2 Hz ... 15 Hz, ±2.5 mm amplitude; 15 Hz ... 150 Hz, 2.3g |
UL approvals | UL Listed UL 61010-1 |
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C | |
UL | |
Identification | UL Listed UL 61010 |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Interference emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | EN 61000-6-3 (Class B) |
Noise emission | EN 61000-6-3 (Class B) |
Harmonic currents | |
Frequency range | 0 kHz ... 2 kHz |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion A |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 1 kV (Test Level 2 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge) | |
Standards/regulations | EN 61000-4-5 |
Input | 2 kV (Test Level 4 - symmetrical) |
4 kV (Test Level 4 - asymmetrical) | |
Output | 1 kV (Test Level 1 - symmetrical) |
2 kV (Test Level 3 - asymmetrical) | |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standard – Safety extra-low voltage | IEC 61010 (SELV) / (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard - safety for equipment for measurement, control, and laboratory use | IEC 61010-1 |
Overvoltage category | |
EN 61010-1 | II |
Mounting type | DIN rail mounting |
Item number | 2907990 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | CMUI13 |
GTIN | 4055626289434 |
Weight per piece (including packing) | 1,238 g |
Weight per piece (excluding packing) | 942 g |
Customs tariff number | 85044083 |
Country of origin | CN |
ECLASS-11.0 | 21052901 |
ECLASS-12.0 | 21052901 |
ECLASS-13.0 | 21052901 |
ETIM 8.0 | EC001184 |
UNSPSC 21.0 | 26111700 |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 25; |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |